C-STAC Recommendations for Changes based on the UF Study on Florida Accessibility Code for Building Construction Review and Recommendation
553.504(1) – Covered Entities
Recommend clarifying and defining
religious entities’ building elements that are not covered.
553.504(2) – Single Family Residential
- Recommend to modify the requirement for
the accessible bathroom and bedroom doors in single
family, duplex and triplex units to match FHA requirements of 32 inch
nominal clear opening.
- Evaluate new construction of single family, duplex and triplex units for
Aging in Place and Visitability. If on accessible habitable level,
bathroom/bathing room or powder room should match FHA requirements.
553.504(5)(a) – Accessible Lav in Toilet Compartment
Recommend removing the “at least 19” wide
by 17” deep, nominal size” from statute.
553.504(5)(b) – Accessible Water Closet Positioned Diagonal to the Door
Recommend elimination of the diagonal
requirement.
553.504(6) – Barrier Removal at Emergency or Common
Entrances
Recommend holding previous position of
deletion:
The University of Florida’s recommendation contains the statement “This
change might be tempered by making it subject to approval by the AHJ.” The
Codes & Standards Technical Advisory Council would like it removed, for we
want all Code to be predictable.
553.5041(4)(c) – Increasing Number of Accessible Parking
Based on Need
Recommend deleting this provision from
the statute.
553.5041(c)(1) – Accessible Parking Spaces Size of 12’ with
5’ Access Aisle
Recommend modifying the accessible
parking space to be 11’ wide with a 5’ access aisle
553.5041(5) (e)(1) and 553.5041(5)(e)(2) – Removal of Architectural
Barriers in Parking Facilities Must Comply Unless Not Readily Achievable.
Alterations must comply to the maximum extent possible.
Recommend deleting provisions in Florida
Statue as this is addressed in federal regulation.
553.511 – Vertical Clearance for Vehicles
Recommend clarifying the sign language.