S1 |
Add to read as follows: 2304.11.4.3 Decks, fences, patios, planters, or
other wooden building components that directly abut the sidewall of the
foundation or structure shall be constructed so as to provide: 1. Eighteen-inch
(457 mm) clearance beneath or, 2. Six-inch
(152 mm) clearance between the top of the component and the exterior wall
covering or, 3. Have
components that are easily removable by screws or hinges to allow access for
inspection of the foundation sidewall and treatment for termites. |
Glitch – (e) Changes to or inconsistencies with federal or
state law. (State agency regulations required to be carried forward) |
|
Tracking ID |
Florida
Building Code, Residential Proposed
Changes |
Comments |
TAC Action |
S2 |
R612.6 Wind-borne debris protection. Protection of
exterior windows and glass doors in buildings located in windborne debris
regions shall be in accordance with Section R301.2.1.2. R612.6.1 Fenestration testing and labeling.
Fenestration shall be tested by an approved independent laboratory, listed by an approved entity, and bear a label
identifying manufacturer, performance characteristics, and approved inspection agency to indicate compliance with the
requirements of the following specification: 1. ASTM E 1886 and ASTM E 1996; or 2. AAMA 506.
Reserved Section R301.2.1.2 Protection of openings. Change
to read as follows: R301.2.1.2 Protection of openings. Exterior
glazing Glazed openings in buildings located in windborne debris regions
shall be protected from windborne debris. Glazed opening protection for
windborne debris shall meet the requirements of the Large Missile Test of
ASTM E 1996 and ASTM E 1886 referenced therein, SSTD 12, TAS 201,202, and 203
or AAMA 506, as applicable. The applicable wind zones for establishing
missile types in ASTM E 1996 are shown in Section R301.2.1.2.1 on Figure
R301.2 (4) . Garage door glazed opening protection for windborne debris shall
meet the requirements of an approved impact-resisting standard or ANSI/DASMA
115 [S5663 AM R1]
[S5718 AS] [S5681 AS] |
Glitch – (a) Conflicts
within the updated code. Conflict with R301.2.1.2. |
|