Comments on the 2013 Update to the
Florida Building Code to considered by the
Swimming Pool TAC
Meeting
Date: August 2, 2013
Tracking ID |
Florida
Building Code, Swimming Pool Proposed
Changes |
Comments |
TAC Action |
SW1 |
FBC, Plumbing Section 403.6 Sanitary facilities
for public swimming pools. Change to read as shown: 403.6 Sanitary facilities for public swimming
pools. Swimming pools with a bathing load of 20
persons or less may utilize a unisex restroom. Pools with bathing loads of 40
persons or less may utilize two unisex restrooms or meet the requirement of
Table 403.6. Unisex restrooms shall meet all the requirements for materials,
drainage and signage as indicated in sections 45 Exception: Where a swimming pool serves only a designated group of
residential dwelling units and not the general public, poolside sanitary
facilities are not required if all living units are within a 200 foot
horizontal radius of the nearest water's edge, are not over three stories in
height unless
serviced by an elevator, and are each equipped with private sanitary facilities.. FBC,
Building 454.1.6
Plumbing systems. 454.1.6.1
Sanitary facilities. Swimming pools with a bathing
load of 20 persons or less may utilize a unisex restroom. Pools with bathing
loads of 40 persons or less may utilize two unisex restrooms or meet the
requirements of Table 454.1.6.1. Unisex restrooms shall meet all the
requirements for materials, drainage and signage as indicated in Sections
454.1.6.1.1 through 454.1.6.1.4. Each shall include a water closet, a diaper
change table, a urinal and a lavatory. Pools with a bathing load larger than
40 persons shall provide separate sanitary facilities labeled for each sex.
The entry doors of all restrooms shall be located within a 200-foot (60 960
mm) walking distance of the nearest water's edge of each pool served by the
facilities. Exception:
Where a swimming pool serves only a designated group of residential dwelling
units and not the general public, poolside sanitary facilities are not
required if all living units are within a 200-foot (60 960 mm) horizontal
radius of the nearest water's edge, are not over three stories in height unless serviced by an
elevator, and are each equipped with private sanitary facilities. (Mod
P5063 / AS) |
Glitch – (a)
Conflicts within the updated
code. |
|