Highlight
of important changes in the 2010 Florida Building Code, Building
Note: Text
highlighted in blue represent Florida specific changes.
Text
highlighted in black represent ICC specific changes.
Chapter 1:
Administration
102.2 – Add new exceptions for family
mausoleums not exceeding 250 square feet and temporary housing provided by
Department of Correction.
102.2.5 – Clarify exemption provisions
for single-family residence located in flood hazard areas.
102.7 – Clarify that relocated
building must comply with the flood hazard area requirements for new location.
102.8 – Clarify when existing
mechanical equipment on the surface of the roof must be installed as per the
FBC.
105.3.7 – Clarify the applicable code for
manufactured buildings.
107.1 Clarification regarding documents submitted at
the time of permit application.
107.3 – Clarify that photocopies of
plans for manufactured buildings are sufficient for local permit.
107.3.5 – Clarify plan review criteria
for flood hazard areas and impact resistant coverings or systems.
111.2 – Clarify the criteria for
certificate of occupancy with respect to flood hazard areas
Chapter 2:
Definitions
Add “High-rise” as new definition for clarification
purposes.
Revise “Story above grade plane” to provide consistency
with the revised definition of “basement”.
Additional terms revised or added:
Addition, Employee Work Area, Floodplain Management Ordinance, Tubular
Daylighting Device, Valley, and Wind-Borne Debris Impact Resistant Products.
Chapter 3: Use and Occupancy
Classification
304.1 – adds new definitions for “Ambulatory health
care facilities”, and “Clinic –outpatient.”
304.2 – Require public and private
colleges and universities to comply with Section 443.
308.5.1 – Classifies “Adult care facility” as Group
R-3 regardless of the number of people being accommodated.
310.1 – Classification of several residential uses
through the inclusion of specific allowances for small transient uses,
live/work units, and small residential care facilities.
Chapter 4: Special Details Requirements.
402.2 – Extends the applications of covered mall
buildings to similar facilities that do not have a roof cover.
402.6.1, 402.8 – Reduce the required open space
around a covered mall building.
403.4.4 – Requires emergency responder radio for
high-rise buildings.
403.5.2 – High-rise more than 420 feet in height
must now provide an additional exit stairway.
403.5.5 – Require luminous for identifying egress in
high-rise as per 1024.
403.6.2 – Allow elevators in high-rise that are in
compliance with 3008 to be used for occupant self-evacuation.
406.2.4 – Increase vehicle barriers from 24 to 33
inches.
408.7 – Provide for provisions for security glazing
in Group I-3 occupancies.
410.3.5 – Update stage proscenium curtains criteria.
419 (IBC 2009) – Live/Work Units was
moved to Section 438 of this Chapter to maintain formatting.
419 (Hospitals) – This section was
revised extensively.
420 (Nursing Homes) – This section was
revised extensively.
421 (Ambulatory Surgical Centers) –
This section was revised extensively.
423.4.2 – Clarify provisions for flood
resistant construction for educational facilities.
423.8.4.1 – Clarify sprinkler system
requirements for remodeled facilities.
423.10.5.5 – Add provision for
playground surface drainage.
423.10.8 – Add new provisions for
irrigation system.
423.16 – Revise to clarify several
plumbing provisions.
423.18 - Revise to clarify provisions
for assembly occupancies in public educational facilities.
423.25.4 – Revise to clarify the
applicable testing standard for impact.
424.1.1 – Add new provision to clarify
the flood resistance requirements for public swimming pools.
424.1.6.1.1 – Clarify the required
fixtures count for public swimming pools.
424.2.4.2.1 – Clarify the flood
requirements for private swimming pools.
424.2.17.1.9 – Revise exist alarm
specification for consistency with UL 2017.
428 – This section was revised
extensively.
439- Revise the separation of dwelling
and sleeping units to include other occupancies within the building.
440 – Add new section to address
“Hydrogen cutoff rooms”.
441 – Add new section to address
“Ambulatory health care facilities”.
442 – Adopt by reference a new shelter
standard “ICC 500”.
443 – Add new section applicable to
schools, colleges and universities.
Chapter 5: General Building Heights and
Areas
502.1 – Revise definition for “basement”.
Table 503 - Revise
allowable heights for Groups B, M, S-1 and S-2.
506.2.1 – Revise the frontage increase for buildings
on the same lot.
506.5 – Revise the method for calculating allowable
area for mixed-occupancy multi-story.
507.6, 507.7 – Provide specific conditions for
unlimited floor area specific to Group A-3.
508.2.5 – Revise the provisions for incidental
accessory occupancies.
Table 508.2.5 – Remove “parking garages” and
“storage rooms” form “Incidental Accessory Occupancies”.
Table 508.4 – Increase the separation for Group I-2.
509.2 – Revise the provisions for horizontal
separation of buildings.
509.5, 509.6 – Provide for special height increases
for Group R-1 occupancies.
509.9 – Provide new provisions for multiple
buildings above Group S-2 parking.
Chapter 6: Types of Construction
602.1 – Clarify the scope of Chapter 6 with regard
to the applicable provisions for 703.
603.1 – Permit FRTW in Type IB construction.
Chapter 7: Fire and Smoke Protection
Features
703.6 – Add provisions for identification of fire
and smoke separation walls.
704 – Clarify the fire-resistance ratings of
structural members.
704.9 – Clarify the impact protection for concrete
columns.
704.13 – Provide requirements for sprayed
fire-resistant materials.
705.2 – Clarify the provisions for projections.
705.5 – Clarify the fire exposure rating for
fire-resistance exterior walls.
Table 705.8 – This table was formatted to be
consistent with the criteria of Table 602.
706.1.1 – Delete the minimum
requirement for 4-hr fire wall and defer such requirement to Section 706.
Table 706.4 – Delete footnote
regarding 4-hr fire wall.
706.5.1 – Provide for requirements specific to fire
wall intersection at exterior walls.
707.3.9 – Clarify separation of fire areas based on
the most restrictive occupancy.
708.2 – Clarify shaft enclosure exceptions.
708.14.1 – Clarify the elevator lobby protection for
Group I-2 in a similar manner to that of Group I-3 and high-rise buildings.
709.1 – Add new exception for other
than dwelling units or sleeping units from tenant separation when a building is
protected by a complete automatic sprinkler system.
712.9 – Clarify the requirements for horizontal
smoke barrios when contain opening.
714.4.1 – Add provisions for exterior curtain
wall/nonfire-resistance rated floor assembly intersection.
716.5.6 – Add specific requirements for protection
of air openings in rated exterior walls.
Chapter 8: Interior Finishes
Note: This
chapter was reformatted to clarify applications specific to interior finishes.
803.11.4 – Modify the standard for thin interior
finishes.
803.13 – Establish minimum testing standard for
“Site-Fabricated Stretch System”.
804.4.1 – Revise classification for floor covering
materials in Group I-1 Occupancies.
Chapter 9: Fire-Protection Systems
902.1 – Revise the definition for “Fire Area” to
address unclosed floor area.
903.2.3 – Reduce the threshold at which the fire
area in Group E Occupancies required to be sprinklered from 2000 to 12,000 SF.
903.2.7 – Require sprinkler systems in Group M
occupancy used for the display and sale of upholstered furniture.
903.2.10 – Clarify the sprinkler requirement for
Group S-2 enclosed parking garages.
903.2.11.1 – Clarify the provisions for stories
without adequate exterior openings.
903.3.1.2.1 – Clarify the requirement for sprinkler
protection of residential balconies and decks.
903.3.1.3 – Extend the applications of NFPA 13D to
townhouses.
906 – Added to address portable fire extinguishers.
907.2 – Clarify the requirements for manual fire
alarm box in Group R-2.
909.3 – Add new provisions for special
inspection and test requirements as per the IBC.
913 – Clarify the separation requirements for
protection of fire pump rooms.
914 – Add provisions for emergency responder safety
features.
916.1.1 – Revise the provisions for
carbon monoxide protection.
Chapter 10: Means of Egress
1002.1 – Add definitions for means of egress terms.
1003.3.3 – Revise provisions for horizontal projections
for consistency with the IBC.
1003.5 – Revise provisions for
elevation change as per the IBC.
1005.1 – Eliminated Table 1005.1 Egress width per
occupant served.
1005.2/1005.3 – Clarify the door hardware
encroachment into egress width.
1008.1.1 – Provide new exception for
building that are 400 square feet or less in area.
1008.1.2 – Allow manually operated horizontal
sliding doors as a means of egress element under limited conditions.
1008.1.9.4 – Provide for exceptions specific to
manually operated edge- or surface mounted bolt locks.
1008.1.9.6 – Provide for special locking conditions
for Group I-2.
1008.1.9.8 – Add provisions for use of
electromagnetically locked egress doors as part of mean of egress.
1008.1.10 – Add an exception for
outdoor gates from residential and commercial swimming pools or swimming pool
decks.
1008.1.10.1 – Add listing requirement for panic
hardware.
1009.4.2 – Add an exception for R-3,
R-2 and Group U as per the IBC.
1009.4.5 – Clarify the application of open risers in
industrial occupancies.
1009.9 – Revise clear width of spiral stairways.
1009.12 – Clarify the requirements for handrails in
Group R-2 and R-3.
1009.13 – Revise provisions for access
to the roof for consistency with the IBC.
1009.14 – Add provision for roof access to elevator
equipment via stairway.
1010.9.1 – Clarify the minimum height for curbs used
as edge protection at ramps.
1011.1 – Revise exist sign provisions
as per the IBC.
1011.1 – Require specific exit sign locations.
1011.4 – Require listing and labeling of internally
illuminated exist signs.
1012.2 – Modify handrail height for alternating
tread devices.
1012.3 – Add criteria for handrail graspability.
1012.4 – Revise provisions for handrail
continuity for consistency with the IBC.
1012.9 – Revise provisions for
intermediate handrails for consistency with the IBC.
1013.1 – Clarify the required locations for guards. Reference HVHZ’s
provisions for guards.
1013.2 – Clarify minimum guard height at fixed
seating.
1013.3 – Clarify opening limitations in the upper
portion of guards.
1014.3 – Clarify the provisions for common path of
egress travel in Group R-2.
1015.1 – Modify the threshold occupant load for
single means of egress from Group R-2 Units.
1016.1 – Clarify measurement of travel distance to
include unenclosed exit access stairways.
1016.2 – Eliminate travel distance increase for roof
vents.
Table 1018.1 – Revise criteria for
corridor fire-resistance rating applicable to Occupancy Group A.
1018.4 – Revise the maximum length of dead ends in
corridors for buildings with automatic sprinkler system.
1021.2/Table 1021.2 – Clarify the provisions for
single exists from individual stories.
1022.1 – Clarify the fire-resistance rating required
for exit enclosures.
1024 – Add new criteria for luminous egress path
markings.
1028.1 – Clarify the egress requirements for Group E
assembly spaces.
1028.4 – Revise the barrier requirements for egress
through Group A-1 Occupancies.
Chapter 11 – Florida Building Code,
Accessibility
Note:
The Accessibility Code has been updated to the 2010 ADA and moved out of
the FBC, Building Volume as a separate sub-code.
Chapter 12: Interior Environment
1202.1 – Clarify the definition for
the term “Sunroom”.
1210.1 – Modify the requirement for wall base finish
materials.
1210.2 – Revise the criteria for walls
and partitions within 2 feet of urinals for consistency with the I-Code.
Chapter 13: Florida Building Code, Energy
Conservation
Note:
The Energy Code has been updated to the 2009 IECC and moved out of the
FBC, Building Volume as a separate sub-code.
Chapter 14: Exterior Walls
1402.1/1408 – Revise provisions for Exterior
Insulation and Finish Systems (EIFS).
1403.2 – Revise water protection
provisions for consistency with I-Code.
1403.5 – Revise flood resistance
criteria.
1404.2 – Clarify the water-resistive
barrier provisions with regard to exterior walls of frame construction
receiving veneers.
1404.5.1 – Modify testing criteria for
AAMA 1402.
1404.9.1 – Add new section to clarify
the labeling criteria for manufactured soffit materials.
1404.10 – Revise compliance provisions
for fiber-cement siding for consistency with the I-Code.
1405.5 – Revise the criteria for
installation of wood veneers as per the I-Code.
1405.6.2 – Modify limitation of use
for TMS 402/ACI 530/ASCE 5 with respect to high-wind areas.
1405.9 – Add new provisions for
installation of terra cotta/ceramic units consistent of those of the I-Code.
1405.14 – Correlate provisions with
2010 ASCE 7.
1405.14.1 – Add new provisions for
application of vinyl siding as per the I-Code.
Chapter 15: Roof Assemblies and Rooftop
1502.1 – Add new definition for
“Building integrated photovoltaic roofing”.
1503.6 – Revise provisions for
crickets and saddles for consistency with I-Code.
1505.8 – Add new provisions specific
labeling requirements for photovoltaic systems.
Table 1507.2.7.1 – Correlate
classification of asphalt shingle with ASCE 7 – 2010.
1507.2.9.2 – Revise the criteria for
open valleys.
1507.2.9.3 – Revise specification for
overlap of drip edge.
1507.3.2/1507.3.3/1507.3.3.1/1507.3.6/1507.3.8/1507.3.9
– Revise provisions to reference RAS 118, 119 or 120 and correlate with ASCE 7
-2010.
1507.15.3 – Add new provisions for
installation and testing of building integrated photovoltaic roofing shingles.
1507.16 – Add provisions for roof gardens and
landscaped roofs.
1509.2 – Clarify the provisions for penthouses.
1509.2.4 – Clarify the use of fire-retardant-treated
wood in penthouses.
Chapter 16: Structural Design
1602.1 – Modify definition for “risk
category”. Add notations for Vasd and
Vult.
1602/Table 1607.1 – Modify live loads for decks and
balconies.
1603 – Correlate provisions with ASCE
7 – 2010.
1604.5 – Correlate provisions with
ASCE 7 – 2010.
1604.8.3 – Revise loading conditions on cantilevered
decks.
1605.1.1 – Add load combination to address stability
analysis.
1605.3.1 – Revise load combination for
consistency with ASCE 7 – 2010.
1605.3.1.1 – Revise load reduction
provisions for clarity.
Figure 1609 – Revise wind speed map(s)
for consistency with ASCE 7 – 2010.
1607.7.1.3 – Allowable stress increase for design of
handrails and guards was deleted.
1607.7.3 – Revise criteria for bumper load
application.
1607.11.2.2 – Clarify the live load design for
special-purpose roofs.
1609.1.1/1609.6 – Add a new simplified wind design
method “Alternate All-height Method”.
1609.1.1 – Adopt by reference the 2008 ICC 600 –
Residential Construction in High-wind Regions. Adopt by reference the latest edition “2010”
of ASCE 7.
1609.1.1.2 – Delete section for
consistency with ASCE 7 – 2010.
1609.1.2 – Limit the application of wood structural
panels as an impact covering to Group R-3 or R-4 occupancy. Add clarification for exterior balconies with regard to
opening protection.
1609.1.2 – Modify ASTM E 1996 for
consistency with ASCE 7 – 2010.
1609.1.2.1 – Reference AMCA 540 as
testing standard for louvers.
1609.1.2.3 – Revise testing criteria
for impact resistant covering for consistency with ASCE 7 – 2010.
1609.1.5 – Provide correlation for
testing to allowable or nominal loads.
1609.2 – Revise definition for
Wind-Borne Debris Region.
1609.3 – Revise the definition for
“Basic wind speed” for consistency with ASCE 7 – 2010.
1609.3.1 – Revise provisions for wind
speed conversions for consistency with ASCE 7 – 2010.
Table 1609.3.1 – Revise “Equivalent
basic wind speed” for consistency with ASCE 7 – 2010.
1609.4.2 – Add definition for “Surface
roughness D” and revise definition for “Surface roughness C” for consistency
with ASCE 7 – 2010.
1609.4.3 – Revise “Exposure
categories” for consistency with ASCE 7 – 2010 and add new exposure “D”.
1609.8 – Add new provisions for
calculating lateral force on rooftop structures and equipment.
1612.1.1 – Add Table 1612.1 providing
cross reference for flood resistant provisions within the FBC.
1612.2 – Add new definition for “Local
Floodplain Management Ordinance”.
1612.3 – Revised to reference “local
floodplain management ordinance”.
1610.1 – Revised to clarify the provisions for
design of foundation walls.
1614 – Add new provisions for structural integrity of
high-rise buildings.
1615 – Reformat to combine Sections
1612, 1613, and 1614 with 1615.
1618.9 – Revise to clarify load
combination with flood load.
1620 – Correlate wind speed with that
of ASCE 7 – 2010.
1620.6 – Add new provisions to clarify
determination of lateral force on rooftop structures and equipment.
1622.1.2 – Add new provision
permitting the use of AAF Guide in high wind areas.
Table 1625.4 – Correlate table with
ASCE 7 – 2010.
1626(h) – Add new provision to clarify
protection of openings for exterior balconies or porches.
Chapter 17: Structural Tests and Special Inspections
1715.5.1 – Revise provisions for
consistency with ASCE 7 – 2010.
1715.6.5.2.1 – Revise to reference
tubular daylight devices as unit skylights.
1715.5.6 – Reference new testing
standard for glazed curtain wall and storefront systems.
1715.9 – Add new provisions for soffit
product approval and installation.
1716.1 – Revise testing standard for
joist hangers and connectors.
Chapter 18: Soil and Foundations
1801.2/1808 – Clarify provisions for design of
footings and foundations.
1802 – Reformat provisions for deep foundations to
resolve conflicts.
1803/1804 – Clarify the update provisions for
geotechnical investigations, excavations, and fill.
1807 – Clarify the analysis for sliding of retaining
walls.
1810.3.1.5 – Add new provisions for helical pile
foundations.
Chapter 19: Concrete
1904/1907 – Clarify provisions for concrete design
and construction in accordance with ACI 318.
1918.1 – Revise provisions for
consistency with ASCE 7 – 2010.
Chapter 20: Aluminum
2002.4 – Add provisions for design of
purlins.
Table 2002.4 – Revise table for
consistency with ASCE 7 – 2010.
2002.6 – Modify AAMA 2100 to clarify
the wind design provisions for sunroom.
2003.9 – Add new provisions for design
and construction of sunrooms in HVHZ.
Chapter 21: Masonry
2101.2/2101.3 – Reformat for consistency with MSJC.
2107.1 – Modify provisions to clarify
specification for lap splices.
2107.5 – Modify ACI 530 with regard to
the determination of development bars.
2101.1/2108.2 – Revise certain
provisions of ACI 530 with regard to plan review and inspections and required
development length of reinforcement.
2121.1.6 – Update reinforcement for
masonry walls.
2122 – This section was revised
extensively.
Chapter 22: Steel
2209.1 – Update the design of cold-formed steel
structural members to AISI S100.
2209.2 – Add new standard for steel decks.
2210 – Update provisions of cold-formed steel
light-framed construction to the latest edition of AISI standards.
2210.3 – Update provisions for trusses as per AISI
S214.
Chapter 23: Wood
2301.2 – Reference new Standard ICC -400 for design
and construction of log structures.
2304.6.1/Table 2304.6.1 – Clarify the provisions for
wood structural panel sheathing used to resist wind loads.
Table 2304.9.1 – Revise Item 31, Wood
structural panels and particleboard, for consistency with ASCE 7 – 2010.
2304.9.5 – Clarify provisions for fasteners in
preservative-treated and fire-retardant-treated wood.
2304.11.2.6 – Clarify provisions for vertical
clearance at wood siding.
2304.11.6 – Revise provisions for
termite protection as per the I-Code.
2306 – Delete provisions for design of wood
structures and defer SDPWS.
Table 2306.6 – Clarification to allowable shear
values were made for consistency with AF&PA.
2307.1 – Add reference to AF&PA SDPWS.
2308.2 – Clarify provisions for maximum
floor-to-floor and stud height. Revise design
limitations of this section for consistency with ASCE 7 – 2010.
2308.3.2 – Clarify provisions for braced line
connections.
2308.9.1 – Clarify the requirements for continuous
studs.
Table 2308.10.1 – Revise table for
correlation with ASCE 7 – 2010.
2314.4.7 – Update several standards to
latest editions.
Chapter 24: Glass and Glazing
2404.2 – Revise to reference tubular
daylighting devices.
2406.1.1 – Reference ANSI Z97.1 as an alternative
standard for impact tests for safety glazing materials.
2411.1 – Clarify when comparative
analysis is acceptable means of evaluation for fixed glazing.
2411.1.11 – Clarify the provisions for
safety glazing with respect to exterior lite of glass.
Chapter 25: Gypsum Board and Plaster
2517.2 – Revise to update standards
for gypsum wallboard and fire resistance.
Chapter 26: Plastic No highlight changes
Chapter 27: Electrical
Section 2705 – Delete exception for
one-and-two-family dwelling from GFCI protection for pool pumps motors.
Chapter 30: Elevators and Conveying Systems
3001.5.3 – Clarify that existing
elevators must comply with ASME A17.3.
3001.6 – Revise definition for “Alteration”.
3002.4 – Clarify the special design
specification for elevator car to accommodate an ambulance stretcher.
3010.1© - Add new provision which
address update to existing elevators for Phase II Firefighters Service.
3013.1 – Revise alteration provisions
for electric and hydraulic elevators and escalators.
3007 – Add new requirements for fire service access
elevator.
3008 – Add new provisions for addressing occupant
evacuation elevators.
Chapter 31: Special Construction
3113.1 – Revise provisions for airport
noise study guidelines.
Chapter 32: Encroachments into the Public
Right-of-way. No
highlight changes
Chapter 33: Safeguards during
Construction. No highlight changes
Chapter 34: Existing Structures. No
highlight changes
Chapter 35: Referenced Standards.
Note: Several standards were added or
updated.