Florida Supplement to the 2012 IRC

Note 1:  Throughout the document, change International Building Code to Florida Building Code, Building; change the ICC Electrical Code to Chapter 27 of the Florida Building Code, Building; change the International Energy Conservation Code to the Florida Building Code, Energy Conservation; change the International Existing Building Code to Florida Building Code, Existing Building; change the International Fire code to Florida Fire Prevention Code; change International Fuel Gas Code to Florida Building Code, Fuel Gas; change the International Mechanical Code to Florida Building Code, Mechanical; change the International Plumbing Code to Florida Building Code, Plumbing; change the International Residential Code to Florida Building Code, Residential.

Note 2:  Criteria blocked in yellow indicate Florida specific language from the 2010 FBC.

 

R101.2  Change to read as shown:

 

R101.2 Scope. The provisions of the Florida Building Code, Residential, shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one– and two–family dwellings and (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures.

 

Exceptions:

 

1-2  No change

 

3. Existing buildings undergoing repair, alteration or additions, and change of occupancy shall comply with the Florida Building Code, Existing Building..

R101.2.1 The provisions of Chapter 1, Florida Building Code, Building, shall govern the administration and enforcement of the Florida Building Code, Residential.

 

CHAPTER 2:  DEFINITIONS

Add the following definitions:

COMMISSION. Means the Florida Building Commission created by this part.

 

 

HIGH VELOCITY HURRICANE ZONE (HVHZ). This zone consists of Broward and Dade counties.

 

MODULAR HOME. Any residential unit, constructed to standards promulgated by the Florida Building Commission, away from the installation site, and which bears a Department of Community Affairs Insignia.

 

REGISTERED TERMITICIDE. Product listed as registered for use as a preventative treatment for termites for new construction by the Florida Department of Agriculture and Consumer Services under authority of Chapter 487, Florida Statutes.

 

CHAPTER 3, BUILDING PLANNING

 

R301.1  Change to read as shown:

 

R301.1 Application, Exception add to read:

EXCEPTION: Buildings and structures located within the High Velocity Hurricane Zone shall comply with Sections R302 to R324, inclusive and the provisions of Chapter R44 and section R406. In addition, buildings and structures located in flood hazard areas established in Table R301.2(1) shall comply with Sections R301.2.4 and R322.

 

R301.2.5 Add to read as follows:

 

R301.2.5 Structures seaward of a coastal control construction line. Structures located seaward of the coastal construction control line shall be designed to resist the predicted forces of a 100-year storm event in accordance with Section 3109 of the Florida Building Code, Building.

 

 

 

R318  PROTECTION AGAINST SUBTERRANNEAN TERMITES. Revise to read as shown:

 

SECTION R318

PROTECTION AGAINST TERMITES

 

R318.1 Termite Protection. Termite protection shall be provided by registered termiticides, including soil applied pesticides, baiting systems, and pesticides applied to wood, or other approved methods of termite protection labeled for use as a preventative treatment to new construction. See §202, REGISTERED TERMITICIDE. Upon completion of the application of the termite protective treatment, a Certificate of Compliance shall be issued to the building department by the licensed pest control company that contains the following statement: "The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services."

R318.1.1 If soil treatment used for subterranean termite prevention, the initial chemical soil treatment inside the foundation perimeter shall be done after all excavation, backfilling and compaction is complete.

R318.1.2If soil treatment is used for subterranean termite prevention, soil area disturbed after initial chemical soil treatment shall be retreated with a chemical soil treatment, including spaces boxed or formed.

R318.1.3 If soil treatment is used for subterranean termite prevention, space in concrete floors boxed out or formed for the subsequent installation of plumbing traps, drains or any other purpose shall be created by using plastic or metal permanently placed forms of sufficient depth to eliminate any planned soil disturbance after initial chemical soil treatment.

R318.1.4 If soil treatment is used for subterranean termite prevention, chemically treated soil shall be protected with a minimum 6 mil vapor retarder to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment is required. Any work, including placement of reinforcing steel, done after chemical treatment until the concrete floor is poured, shall be done in such manner as to avoid penetrating or disturbing treated soil.

R318.1.5 If soil treatment is used for subterranean termite prevention, concrete overpour or mortar accumulated along the exterior foundation perimeter shall be removed prior to exterior chemical soil treatment, to enhance vertical penetration of the chemicals.

R318.1.6 If soil treatment is used for subterranean termite prevention, chemical soil treatments shall also be applied under all exterior concrete or grade within 1 foot (305 mm) of the primary structure sidewalls. Also, a vertical chemical barrier shall be applied promptly after construction is completed, including initial landscaping and irrigation/sprinkler installation. Any soil disturbed after the chemical vertical barrier is applied shall be promptly retreated.

R318.1.7 If a registered termiticide formulated and registered as a bait system is used for subterranean termite prevention, §R318.1.1 through §R318.1.6 do not apply; however, a signed contract assuring the installation, maintenance and monitoring of the baiting system for a  minimum of five years from the issue of the Certificate of Occupancy shall be provided to the building official prior to the pouring of the slab, and the system must be installed prior to final building approval.

    If the baiting system directions for use require a monitoring phase prior to installation of the pesticide active ingredient, the installation of the monitoring phase components shall be deemed to constitute installation of the system.

R318.1.8 If a registered termiticide formulated and registered as a wood treatment is used for subterranean termite prevention, Sections R318.1.1 through R318.1.6 do not apply. Application of the wood treatment termiticide shall be as required by label directions for use, and must be completed prior to final building approval.

 

R318.2 Penetration. Protective sleeves around piping penetrating concrete slab-on-grade floors shall not be of cellulose-containing materials. If soil treatment is used for subterranean termite protection, the sleeve shall have a maximum wall thickness of 0.010 inch (0.25 mm), and be sealed within the slab using a non-corrosive clamping device to eliminate the annular space between the pipe and the sleeve. No termiticides shall be applied inside the sleeve.

 

R318.3 Cleaning. Cells and cavities in masonry units and air gaps between brick, stone or masonry veneers and the structure shall be cleaned of all non-preservative treated or non-naturally durable wood, or other cellulose-containing material prior to concrete placement.

Exception:  Inorganic material manufactured for closing cells in foundation concrete masonry unit construction or clean earth fill placed in concrete masonry unit voids below slab level before termite treatment is performed.

 

R318.4 Concrete bearing ledge. Brick, stone or other veneer shall be supported by a concrete bearing ledge at least equal to the total thickness of the brick, stone or other veneer which is poured integrally with the concrete foundation. No supplemental concrete foundation pours which will create a hidden cold joint shall be used without supplemental treatment in the foundation unless there is an approved physical barrier. An approved physical barrier shall also be installed from below the wall sill plate or first block course horizontally to embed in a mortar joint. If masonry veneer extends below grade, a termite protective treatment must be applied to the cavity created between the veneer and the foundation, in lieu of a physical barrier.

Exception: Veneer supported by a structural member secured to the foundation sidewall in accordance with ACI 530/ASCE 5/TMS 402, provided at least a 6 inch (152 mm) clear inspection space of the foundation sidewall exterior exist between the veneer and the top of any soil, sod, mulch or other organic landscaping component, deck, apron, porch, walk or any other work immediately adjacent to or adjoining the structure.

 

R318.5  Protection against decay and termites, add text to read as shown:

 

R318.5 Protection against decay and termites. Condensate Lines, irrigation/sprinkler system risers for spray heads, and roof downspouts shall discharge at least 1 foot (305 mm) away from the structure sidewall, whether by underground piping, tail extensions or splash blocks. Gutters with downspouts are required on all buildings with eaves of less than 6 inches (152 mm) horizontal projection except for gable end rakes or on a roof above another roof.

 

R318.6 Preparation of building site and removal of debris. Add text to read as shown:

 

R318.6 Preparation of building site and removal of debris.

R318.6.1 All building sites shall be graded to provide drainage under all portions of the building not occupied by basements.

R318.6.2 The foundation and the area encompassed within 1 foot (305 mm) therein shall have all vegetation, stumps, dead roots, cardboard, trash and foreign material removed and the fill material shall be free of vegetation and foreign material. The fill shall be compacted to assure adequate support of the foundation.

R318.6.3 After all work is completed, loose wood and debris shall be completely removed from under the building and within 1 foot (305 mm) thereof. All wood forms and supports shall be completely removed. This includes, but is not limited to: wooden grade stakes, forms, contraction spacers, tub trap boxes, plumbing supports, bracing, shoring, forms or other cellulose-containing material placed in any location where such materials are not clearly visible and readily removable prior to completion of the work.  Wood shall not be stored in contact with the ground under any building.

 

 

 

Revise R322.1.7 to read as follows:

 

R322.1.7 Protection of water supply and sanitary sewage systems. New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the systems in accordance with the plumbing provisions of this code. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into systems and discharges from systems into floodwaters in accordance with the plumbing provisions of this code and in accordance with Chapter 64E-6, Florida Administrative Code, Standards for Onsite Sewage Treatment and Disposal Systems. and Chapter 3 of the International Private Sewage Disposal Code.

 

R322.1.9 Manufactures homes. Revise to read as shown:

R322.1.9 Manufactured homes.  In addition to the applicable requirements of the state agency with jurisdiction over installation of manufactured homes, installation of manufactured homes in flood hazard areas is subject to the applicable provisions of the local floodplain management ordinance.

 

R322.1.11 Structural seaward of  a coastal construction line.  Add section to read as shown:

 

R322.1.11 Structures seaward of a coastal construction line. In addition to the requirements of this section, structures located in flood hazard areas and seaward of the coastal construction line shall be designed to resist the predicted forces of a 100-year storm event in accordance with Section R3109 of the Florida Building Code, Building, and the more restrictive provisions shall govern. 

 

 

Revise to add R322.3.3.1 as a new section. 

R322.3.3.1 Pools. Pools in coastal high-hazard areas shall be designed and constructed in conformance with ASCE 24.

 

 

CHAPTER 4:  FOUNDATIONS

 

Section R401.1 Application, revise text to add exception 3 to read as follows:

 

3. Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44 and, as applicable, Section R322 in flood hazard areas.

 

 

CHAPTER 5 FLOORS

 

R501.1 Application. Change to read as follows:

 

R501.1 Application. The provisions of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces used to house mechanical and/or plumbing fixtures and equipment.

Exception: Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44.

 

 

Chapter 7 Wall Covering

 

 

Add exception to R701.1 as follows:

 

R701.1 Application. The provisions of this chapter shall control the design and construction of the interior and exterior wall covering for all buildings.

Exception: Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44.

 

 

Add Section 704 to read as follows:

 

SECTION 704

INSPECTION FOR TERMITES

 

In order to provide for inspection for termite infestation, clearance between exterior wall coverings and final earth grade on the exterior of a building shall not be less than 6 inches (152 mm).

Exceptions:

1.    Paint or decorative cementitious finish less than 5/8 inch (17.1 mm) thick adhered directly to the masonry foundation sidewall.

2.    Access or vehicle ramps which rise to the interior finish floor elevation for the width of such ramps only.

3.    A 4-inch (102 mm) inspection space above patio and garage slabs and entry areas.

4.    If the patio has been soil treated for termites, the finish elevation may match the building interior finish floor elevations on masonry construction only.

5.    Masonry veneers constructed in accordance with R318.4.

 

CHAPTER 8

ROOF-CEILING CONSTRUCTION

 

Add an exception to R801.1 as shown:

 

R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings (see Section R301.2.1.1).

Exception: Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44.

 

CHAPTER 9

ROOF ASSEMBLIES

 

Add exception to R901.1 as shown:

 

R901.1 Scope.  The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies.

Exception: Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44.

 

 

Chapter 11, Energy Efficiency

 

 

SECTION N1101, GENERAL.  Revise to read as shown:

 

N1101 Energy efficiency. The provisions of the Florida Building Code, Energy Conservation, shall govern the energy efficiency of residential construction.

 

 

 

Chapter 26, General Plumbing Requirements

 

P2603.3 Breakage and corrosion. Revise to read as shown:

 

P2603.3 Breakage and corrosion. Pipes passing through concrete or cinder walls and floors, cold-formed steel framing or other corrosive material shall be protected against external corrosion by a protective sheathing or wrapping or other means that will withstand any reaction from lime and acid of concrete, cinder or other corrosive material. Sheathing or wrapping shall allow for movement including expansion and contraction of piping. Minimum wall thickness of material shall be 0.010 inch (0.254 mm).

Exception: Sleeving is not required for installation of CPVC into concrete or similar material

 

P2603.3.1 Penetration.  Add text to read as shown:

 

P2603.3.1 Penetration. Protective sleeves around piping penetrating concrete slab-on-grade floors shall not be of cellulose-containing materials. If soil treatment is used for subterranean termite protection, the sleeve shall have a maximum wall thickness of 0.010 inch, and be sealed within the slab using a non-corrosive clamping device to eliminate the annular space between the pipe and the sleeve. No termiticides shall be applied inside the sleeve.

 

 

 

CHAPTER 44 45

REFERENCED STANDARDS

 

 

Add the following standards:

 

AAMA       American Architectural Manufacturers Association

                   1827 Walden Office Square, Suite 550

                    Schaumburg, IL 60173

 

                                              

203-98                 Procedural Guide for the Window Inspection and Notification System                        R4410.2.3.2.6

 

501—94               Methods of Test for Exterior Walls                                                                                 R4410.2.3.2.1

1302-76                         Voluntary Specifications for Forced-entry Resistant Aluminum Prime

                             Windows                                                                                                            R4410.2.3.2.1

 

1600/I.S. 7-00      Voluntary Specifications for Skylights                                                                                 R4412.1.2

 

ACI           American Concrete Institute

                   38800 Country Club Drive

                  Farmington Hills, MI 48331

 

117                        Standard Tolerances for Concrete Construction and Materials                                          R4405.2.2

301                        Specifications for Structural Concrete for Buildings                                                            R4405.2.2

315                        Manual of Standard Practice for Detailing Reinforced Concrete Structures                     R4405.2.2

 

347                        Recommended Practice for Concrete Formwork                                            R4405.2.2, R4405.7.1.1

506                        Recommended Practice for Shotcreting                                                                               R4405.2.2

506.2                     Building Code Requirements for Masonry Structures            R4405.2.2, R4405.11.1.2, R4405.11.8.1

530/530.1-11         Building Code Requirements for Masonry Structures and Specifications               R404.1, R606.1,

                               for Masonry Structures & Commentaries                                         R606.1.1, R4403.7.8, R4407.5.1

 

AFPA           American Forest and Paper Association (American Wood Council Division)

                      111 19th Street, NW, #800

                      Washington, DC 20036

 

NDS—12               National Design Specification (NDS) for Wood Construction with                      R404.2.2, R502.2,

                             2001 Supplement                                                         Table R503.1, R602.2, R802.2, R4404.7.1.8.1,

                                             R4409.1.4.7, R4409.2.4.1, R4409.6.17.2.1.3, R4409.6.17.2.1.3, R4409.6.17.2.1.5

AFPA—05            Design Values for Wood Construction                                   R4409.1.4.7, R4409.6.17.2.2.1

AFPA—92            Wood Structural Design Data                                                                                             R4409.1.4.7

AFPA—9305        Working stresses for Joists and Rafters Design Values for Joists and Rafters                                                                             R4409.1.4.7

AFPA—2012        Span Tables for Joists and Rafters           R502.2.2, R802.2.2, R802.2.3, R4409.1.4.7, R4409.4.1.1

T.R. No. 7—87     Basic Requirements for Permanent Wood Foundation System   PWF--07 Permanent Wood Foundation (PWF) Design Specification     R401.1, R4409.1.4.7

WCD 1—01          Wood Construction Data No. 1, Details for Conventional Wood Frame Construction   R4409.1.4.7

WCD 4—03          Wood Construction Data number 4, Plank and Beam Framing for Residential Building 4409.1.4.7

WCD 5—04          Wood Construction Data No. 5, Heavy Timber Construction Details                               R4409.1.4.7

WCD 6—0106     Wood Construction Data No.6, Design of Wood Frame structures for Permanence      R4409.1.4.7,

                                                                                                                                                                   R4409.13.2.11

WFCM— 08 01   Wood Frame Construction Manual for One- and Two-family Dwellings                       R301.2.1.1, R404.1.4,

                                                                                                                        R614.2.5, R614.3.1, R802.2, R4409.1.4.7

 

AHA                       American Hardboard Association

                             1210 West Northwest Highway

                             Palatine, IL 60067                               

                                                                                                              Referenced in code

reference number    Title                                                                                           section number

A135.4—04          Basic Hardboard                                                                                    Table R602.2(1), R4409.1.4.1

A135.5—04          Prefinished Hardboard Paneling                                                                            R702.5, R4409.1.4.1

A135.6—98          Hardboard Siding                                                                                                       Table R703.4, R4409.1.4.1

IB Spec. No. 1      Recommended Product and Application Specification-Structural

                             Insulating Roof Deck                                                                                                             R4409.1.4.1

IB Spec. No. 2      Recommended Product and Application Specification-½ inch

                             Fiberboard Nail-Base Sheathing                                                                                            R4409.1.4.1

IB Spec. No. 3      Recommended Product and Application Specification-½ inch

                             Intermediate Fiberboard Sheathing                                                                                     R4409.1.4.1

 

AISC       American Institute of Steel Construction

                One East Wacker Drive Suite 3100

                Chicago, IL 60601-2001

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

AISC                     Detailing for Steel Construction                                                                   R4408.1.3

AISC                     Engineering for Steel Construction                                                               R4408.1.3

AISC                      Iron and Steel Beams 1873 to 1952                                                R4408.1.3

AISC                      Serviceability Design Considerations for Low Rise Buildings                     R4408.1.3

AISC                     Torsional Analysis of Steel Members                                                            R4408.1.3

AISC                     Manual of Steel Construction, 2005,

                       Thirteenth edition,including Specification for Structural Steel Buildings R4408.1.3                                                                           

 AISI            American Iron and Steel Institute

                    1140 Connecticut Ave, Suite 705

                    Washington, DC 20036

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

AISI                  Design Manual for Structural Tubing                                                                                       R4408.1.3

AISI                  Designing Fire Protection for Steel Trusses                                                                                R4408.1.3

AISI                  Designing Fire Protection for Steel Columns                                                                             R4408.1.3

AISI                  Fire Resistant Steel Frame Construction                                                                                   R4408.1.3

AISI                  Fire Safe Structural Steel A Design                                                                                            R4408.1.3

AISI                   Specifications for Design of Light Gage Cold Formed Stainless Structural Members         R4408.1.3

AISI                   Specification for the Criteria for Structural Application of Steel Cables for Buildings        R4408.1.3

SGO4-5             Standard for Cold formed Steel Framing Truss Design                                                             R804.1.3

SGO4-6             Standard for Cold formed Steel Framing Header Design                                                       R603.6

SGO3-3             Cold Formed Steel Design Manual                                                                                           R4408.1.3

SG 971—96       Specification for the Design of Cold Form Steel Structures                                                   R4408.1.3

 

AITC         American Institute of Timber Construction

                   7012 S. Revere Parkway, Suite 140

                   Englewood, CO 80112

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

AITC 104             Typical Construction Details                                                                                              R4408.1.4.2

AITC 106             Code of Suggested Practices                                                                                               R4409.1.4.2

AITC 108             Standard for Heavy Timber Construction                                                                        R4409.1.4.2

AITC 109             Standard for Preservative Treatment for Structural Glued Laminated Timber                R4409.1.4.2

AITC 110             Standard Appearance Grades for Structural Glued Laminate Timber                             R4409.1.4.2

AITC 112             Standard for Torque and Groove Heavy Timber Roof Decking                                                     R4409.1.4.2

AITC 113             Standard for Dimensions of Glued Laminated Structural Members                                R4409.1.4.2

AITC 117             Standard Specification for Structural Glued Laminated Timber of Softwood Species   R4409.1.4.2

AITC 119             Standard Specifications for Hardwood Glued Laminated Timber                                   R4409.1.4.2

AITC A 190.1— 07 Structural Glued Laminated Timber  R502.1.1.5, R602.1.1.2, R802.1.5, R4409.1.4.2, R4409.2.11

TR No. 7               Calculation of Fire Resistance of Glued Laminated Timber                                            R4409.1.4.2

 

ANSI        American National Standards Institute

                  25 West 43rd Street, Fourth Floor

                  New York, NY 10036

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

A41.1                 Building Code Requirements for Masonry                                                      R4407.2.1.1, R4407.4.2.8

A41.2                 Building Code Requirements for Reinforced Masonry                                                        R4407.2.1.1

A42.1                 Standard Specification for Gypsum Plastering                                                                    R4411.2.1.1

A42.4                 Standard Specification for Interior Lathing and Furring                                                           R4411.1

Z97.1— 09  Safety Glazing Materials Used in Buildings—Safety Performance

                                  Specifications and Methods of Test (Reaffirmed 1994)                               R308.3, R4403.7.3.6.3,

                                                                                                                                                 R4410.2.1.4, R4410.2.1.6

APA                     APA The Engineered Wood Association

                             7011 South 19th

                             Tacoma, WA 98466

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

V910               Plywood Folded Plate, Laboratory Report 21                                                                        R4409.1.4.3

L350               Design/Construction Guide Diaphragms                                                                                  R4409.1.4.3

PRP108           Performance Standards and Policies for Structural Use Panels                        R4409.1.4.3, R4409.2.1.2

B840               303 Siding Manufacturing Specifications                                                                               R4409.1.4.3

E30—03         Engineered Wood Construction Guide                                                                   R803.2.3, R4409.1.4.3

H815               Plywood Design Specification Design and Fabrication of All Plywood Beams                   R4409.1.4.3

S811                Plywood Design Specification Design and Fabrication of Plywood Curved Panels               R4409.1.4.3

S812                Plywood Design Specification Design and Fabrication of Plywood Lumber Beams          R4409.1.4.3

U813               Plywood Design Specification Design and Fabrication of Plywood Stressed Skin Panels  R4409.1.4.3

U814               Plywood Design Specification Design and Fabrication of Plywood Sandwich Panels        R4409.1.4.3

Y510J              Plywood Design Specification                                                                                  R4409.1.4.3

 

 

ASCE          American Society of Civil Engineers

                     1801 Alexander Bell Drive

                     Reston, VA 20191-4400

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

3—91         Specifications for the Design and Construction of Composite Slabs and Commentary

                  on Specifications for the Design and Construction of Composite Slabs                     R4405.2.3, R4408.1.3

5— 08   Building Code Requirements for Masonry Structures      R404.1, R606.1, R606.1.1, R606.2.2, R606.11.1,

                                                                                                   R606.11.2.2.1, R606.11.2.2.2, R606.11.3.1, R4403.7.8

7— 10       Minimum Design Loads for Buildings and Other Structures     Figure 301.2(4), R301.2.1.1, R301.2.1.1.2,

                                      R301.2.1.4, Table R611.3(1), Table R611.7.4, R4402.3.4, R4403.1.3, R4403.4.1, R4403.4.2,

                              R4403.7.3.8, R4403.7.8, R4403.8, R4403.9, R4403.10, R4403.12, Table R4403.15.4, R4403.16.1

8—02        Specifications for the Design of Cold Formed Stainless Steel Structural members             R4408.1.3

11—99      Guidelines for Structural Condition Assessment of   Existing Buildings  R4405.2.3, R4406.1.2, R4408.1.3

32—01      Design and Construction of Frost Protected Shallow Foundations                             R403.1.4.1, R4406.1.2

 

ASME                American Society of Mechanical Engineers

                           Three Park Avenue

                            New York, NY 10016-5990

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

B16.3— 2006     Malleable Iron Threaded Fittings Classes 150 and 300                     Table P2904.6, Table R4413.2.7

B16.4—  2006     Gray iron Threaded Fittings Classes 125 and 250              Table P2904.6, Table R4413.2.7

B16.9—2003               Factory made Wrought Steel Buttwelding Fittings                     Table P2904.6, Table R4413.2.7

B16.11—2005    Forged Fittings, Socket welding and Threaded                                  Table P2904.6, Table R4413.2.7

B16.12—1998             Cast Iron Threaded Drainage Fittings                                       Table P2904.6, Table R4413.2.7

B16.15— 2006 Cast Bronze Threaded Fittings                                              Table P2904.6, Table R4413.2.7

B16.18—2001 (R2005)  Cast Copper Alloy Solder Joint Pressure Fittings      Table P2904.6, Table R4413.2.7

B16.22—2001  (R2005)  Wrought Copper and Copper Alloy Solder Joint Pressure Fittings   Table P2904.6, Table R4413.2.7

ASTM              ASTM International

                         100 Barr Harbor Drive

                         West Conshohocken, PA 19428

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

A 6/A6M—04a       Specification for General Requirements for Rolled Structural Steel Bars,

                                Plates, Shapes and Sheet Piling                                                                                             R4408.1.3

A 29/A29M             Specification for Steel bars, Carbon and Alloy, Hot Wrought, General

                                Requirements                                                                                                                     R4404.11.1

A 53/A53M— 06a Specification for Pipe, Steel, Black and Hot dipped, Zinc Coated Table 2904.4.1

                            Welded and Seamless Table M2101.1, Table P2904.5, Table P3002.1, G2414.4.2, Table R4413.2.2

A 74— 09            Specification for Cast Iron Soil Pipe and Fittings                                  Table P3002.1,Table P3002.2,

                                                                          Table R4413.2.2, Table R4413.2.3, Table R4413.2.4, Table R4413.2.5

A 82/A 82M -05a                Specification for Steel Wire, Plain for Concrete Reinforcement

                                                          R606.9.10

A 306                        Carbon Steel Bars Subject to Mechanical Property Requirements                                R4404.11.1

A 307—07b               Specification for Carbon Steel Bolts and Studs 60,000 PSI Tensile Strength

                                       Table R611.9

A 325—94                Specification for High Strength Bolts for Structural Steel Joints                           R4408.1.3

A 361                        Specification for Steel Sheet Zinc Coated (Withdrawn)                                           R4409.6.17.1.1

A 416 - 99                   Specification for Steel Strand, Uncoated Seven Wire for Prestressed Concrete

                                         R4405.4.4.2

A 421/A421M—98   Specification for Uncoated Stress Relieved Steel Wire for Prestressed Concrete      R4405.4.4.2

A 446                        Specification for Steel Sheet, Zinc Coated (Galvanized) by the Hot Dip

                                  Process, Structural (Physical) Quality                                                                            R4405.12.4.4

               

A 490—93                Specification for Heat Treated Steel Structural Bolts                                                      R4408.1.3

A 525 - 87              Specification for Steel Sheet Zinc coated (Galvanized) Steel Wire  Table R606.9.10.1,

                                                                 R4405.12.4.4, R4408.1.3, R4411.4.2, R4411.4.5.1, R4411.4.5.4, M1601.1.1

A 611                    Standard Specification for Structural Steel (SS), Sheet, Carbon, Coil Rolled    R4404.10.1.5.3,

                                                                                                                                                                     R4405.12.4.4

A 615/A 615M-09 Specification for Deformed and Plain Billet Steel Bars for Concrete

                                 Reinforcement                                                                            R4405.2.2, R4405.2.4, R4405.4.4.6

A 617                      Standard Specification for Axle Steel Reformed and Plain Bars for

                                Concrete Reinforcement                                                                                                   R4405.4.4.6

A 653/A 653M-08  Specification for Steel Sheet, Zinc Coated (Galvanized) or Zinc Iron             R505.2.1, R505.2.3,

                        Alloy Coated (Galvanized) by the Hot Dip Process                    R603.2.1, R603.2.3, R804.2.1, R804.2.3,

                                                                                                          Table 905.4.4, Table R905.10.3, R4409.6.17.2.2.7

A 706/A 706M-09  Specification for Low Alloy Steel Deformed and Plain Bars for

                               Concrete Reinforcement                                                    R404.4.6.1, R611.6.2, R4405.4.4

A 722/A 722M-98  Specification for Uncoated High Strength Steel Bar for Prestressing Concrete          R4405.4.4.2

A 767/A 767M-00b Specification for Zinc Coated (Galvanized) Steel Bars for Concrete

                                Reinforcement                                                                                             R4405.4.4.6, R4405.8.5.5

A 775/A 775M-01   Specification for Epoxy Coated Steel Reinforcing Bars                                              R4405.4.4.6

A 888- 09          Specification for Hubless Cast Iron Soil Pipe and Fittings for      Table P3002.1, Table P3002.2,

                                 Sanitary And Storm Drain, Waste, and Vent Piping Application                        Table R4413.2.2,

                                                                          Table R4413.2.3, Table R4413.2.4, Table R4413.2.5, Table R4413.2.7

A 924/A924M-08a   Standard Specification for General Requirements for Steel Sheet, Metallic

                                Coated by the Hot Dip Process                                                                                  R4409.6.17.2.2.7

B 43—98 (2004)       Specification for Seamless Red Brass Pipe, Standard Sizes              Table M2101.1, G2413.5.2,

                                                                                   Table P3002.1, Table P2904.4.1Table P2904.5, Table R4413.2.2

B 75— 02        Specification for Seamless Copper Tube                    Table M2101.1, Table P2904.4.1, Table P2904.5,

                                                    Table P3002.1, Table P3002.2, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4

B 88—03     Specification for Seamless Copper Water TubeTable M2101.1, G2414.5.2, Table P2904.4.1,

                          Table P2904.5, Table P3002.1, Table P3002.2, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4

B 227—04        Specification for Hard drawn Copper clad Steel Wire                                                            R606.9.10

B 251—02e01  Specification for General Requirements for Wrought Seamless Copper and Copper   Table M2101.1,

                          alloy Tube      Table P2904.4.1, Table P2904.5, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4

B 302—07   Specification for Threadless Copper Pipe, Standard Sizes                     Table M2101.1, Table P2904.4.1,

                                                                                                                       Table P2904.5, P2904.4, Table R4413.2.2

B 306—09    Specification for Copper Drainage Tube (DWV)            Table M2101.1, Table P3002.1, Table P3002.2,

                                                                                                                                   Table R4413.2.2, Table R4413.2.4

B 370—09    Specification for Copper Sheet and Strip for Building Construction                                 Table R905.4.4

                                                                                                                                      Table R905.10.3, Table P2701.1

B695-  04

C4—  04e01 Specification for Clay Drain Tile and Perforated Clay Drain Tile  Table R4413.2.4, Table R4413.2.5

C5—03     Specification for Quicklime for Structural Purposes                                       R702.2, R4411.2.2.3

C 14—07  Specification for Concrete Sewer, Storm Drain, and Culvert Pipe     Table P3002.2, Table R4413.2.4

C 28/C28M- 00(2005) Specification for Gypsum Plasters                                                    R702.2, R4411.2.2.2

C 31/C 31M-98Practice for Making and Curing Concrete Test Specimens in the Field  R4405.5.2.2.3, R4405.5.2.3.2

C 33— 08     Specification for Concrete Aggregates                                                    R4405.4.2, R4405.4.2.2

C 34-03  Specification for Structural Clay Load bearing Wall Tile                 Table R301.2(1), R4407.2.8.3.1

C 35-9501(2005)  Specification for Inorganic Aggregates for Use in Gypsum Plaster        R702.2, R4411.2.2.1.1

C 36/C 36M-03 Specification for Gypsum Wallboard                                                   R702.3.1, N1100.7,  R4411.4.2

C 37/C 37M-01 Specification for Gypsum Lath                                                                                R702.2, R4411.1.2

C 39—99ael      Test Method for Compressive Strength of Cylindrical Concrete Specimens                    R4405.5.2.2.3

C 42/C 42M-99 Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete     R4405.5.2.4

C 52                   Specification for Gypsum Partition Tile or Block                                                                  R4407.2.9.3

C 55— 06e01   Specification for Concrete Brick              R202, Table R301.2(1), R4407.2.4.2.2, R4407.2.4.3.3

C 56-96 (2001)  Specification for Structural Clay Nonload Bearing Tile                                                  R4407.2.8.3.3

C 57                   Specification for Structural Clay Floor Tile                                                                       R4407.2.8.3.2

C 59/C 59M-00 (2006)    Specification for Gypsum Casting and Molding Plaster                                                             R702.2

C 61/C 61M-00  (2006)    Specification for Gypsum Keene’s Cement                       R702.2, R4411.1.2, R4411.2.2.4

C 62—  08        Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)                R202,

C 67—03ae01         Test Methods of Sampling and Testing Brick and Structural Clay Tile                      R905.3.5, R4407.2.4.2

C 76—  08         Specification for Reinforced Concrete Culver, storm Drain and Sewer Pipe                Table R4413.2.4

C 90—08              Specification for Load Bearing Concrete Masonry Units     Table R301.2(1), R606.4,

                                                                      R4407.2.7.2

C 91— 05             Specification for Masonry Cement                                                                              R4412.2.2.6

C 94/C 94M -09          Specification for Ready Mixed Concrete               R404.1.2.3.2, R611.5.1.1,

                                                         R4405.6.2

C 144—03            Standard Specification for Aggregate for Masonry Mortar                 R4405.10.7.2, R4407.2.12.1.1

C 150— 07      Specification for Portland Cement                                                        R4405.4.1, R4412.2.2.5.1

C 172—99             Practice for Sampling Freshly Mixed Concrete                                                                R4405.2.2.2

C 177-04 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus            Table R301.2(1), N1110.AB.2.2

                                                                                                                                     R4407.2.4.3.1

C 199-84(2005)    Test Method for Pier Test for Refractory Mortar                 R1001.9, R1003.5, R1003.8, R4405.4.1

C 206-84(1997)    Specification for Finishing Hydrated Lime                                                                     R4411.2.2.3

C 212—00            Specification for Structural Clay Facing Tile                                                     R4407.2.8.2

C 216— 07a     Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)                    R202,

                                                                                                                                        Table R301.2(1), R4407.2.4.3.1

C 236-89 (1993el)               Test Method For Steady-State Thermal Performance of Building

Assemblies by Means of a Guarded Hot Box.                              Appendix G C2.2.2

 

C 270—   08a      Specification for Mortar for Unit Masonry                                                        R607.1, R4407.2.12.1

C 330—99            Specification for Lightweight Aggregates for Structural Concrete                                       R4405.4.2

C 332—99            Standard Specification for Lightweight Aggregates for Insulation Concrete                  R4405.12.4.6

C 425-04              Specification for Compression Joints for Vitrified Clay Pipe and FittingsTable P3002.2, P3003.3.5

C 428-05(2006)   Specification for Asbestos Cement Nonpressure Sewer pipe        Table R4413.2.3, Table R4413.2.4

C 471M-01      Standard Test Methods for Chemical Analysis of Gypsum and Gypsum Products            R4407.2.9.2,

                                                                                                                                                                       R4407.2.9.3

C 472—99       Specification for Standard Test Methods for Physical Testing of Gypsum,

                        Gypsum Plasters and Gypsum Concrete                                                             R4407.2.9.2, R4407.2.9.3

C 473—00       Test Method for Physical Testing of Gypsum Panel Products                         R4407.2.9.2, R4407.2.9.3

C 475/C475M—02(2007) Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard     R702.3.1,

                                                                                                                                                                 R4411.4.2

C 494/C 494M-99 Standard Specification for Chemical Admixtures for Concrete                                   R4405.12.4.4

C 495-99a        Standard Test Method for Compressive Strength of Lightweight Insulating Concrete    R4405.12.1.1,

                                                                                                                                             R4405.12.1.2, R4405.12.1.3

C 508—00 04      Specification for Asbestos Cement Underdrain Pipe                                                 Table R4413.2.5

C 509-00               Elastomeric Cellular Preformed Gaskets and Sealing Material                     R4410.2.3.4

 

 

C 516-02                               Vermiculite Loose Fill Thermal Insulation                                     Appendix G Table B1.2.3

C 518-04 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus                                                                                       N1110.AB.2.2

C 549-06                               Perlite Loose Fill Insulation                                                               Appendix G Table B-1.2.3

C 578-  08b                           Rigid, Cellular Polystyrene Thermal Insulation                             Appendix G Table B-1.2.3

C 595— 08a       Specification for Blended Hydraulic Cement                                                        R4405.4.1

C 618—99       Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolar for Use

                         as a  Mineral Admixture in Concrete                                                                                     R4405.12.4.4

C 645— 08a     Specification for Nonstructural Steel Framing Members        R702.3.3, R4409.6.17.1.3, R4411.4.2,

                                                                                                                                                 R4411.4.5.1, R4411.4.5.4

C 652—09  Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)                    R202,

                                                                                                                                  Table R301.2(1), R4407.2.4.3.1

C 665-06                               Mineral-Fiber Blanket Thermal Insulation for Light Frame

Construction and Manufactured Housing                                     Appendix G Table B-1.2.3

C 685 - 07 Specification for Concrete Made by Volumetric Batching and Continuous Mixing   R4405.6.2.2

C 700- 07a  Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated Table P3002.2,

                                                                                                        R4409.6.17.1.3, Table R4413.2.4, Table R4413.2.5

C 727-01                               Standard Practice for Installation and Use of Reflective

Insulation in Building Constructions.                                              Appendix G Table B-1.2.3

C 739-05b             Cellulosic Fiber (Wood-Base) Loose-Fill Thermal Insulation     Appendix G Table B-1.2.3

C 764-06a             Mineral Fiber Loose-Fill Thermal Insulation                                  Appendix G Table B-1.2.3

 

C 794—01    Test Method for Adhesion in Peel of Elastometric Joint Sealants                                             R4410.6.4

C 796—97    Standard Test Method for Foaming Agents for Use in  Producing Cellular Concrete

                     Using Performed Foam                       R4405.12.1.1, R4405.12.1.2, R4405.12.1.3, R4405.12.4.6

C 864-05               Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers   R4410.2.3.4

 

 

C 869          Specification for Foaming Agents Used in Making Performed Foam for Cellular Concrete R4405.12.4.6

C 887- 05 Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar           R406.1

C 920 - 08 Specification for Elastomeric Joint Sealants …………………... R4410.6.4, R613.8.1  

C 926-06   Specification for Application of Portland Cement Based Plaster  R202, R703.6.2.1, R4411.3.1.1,

                                                                                                                                                                       R4411.3.1.4

C 1015-06             Standard Practice for Installation of Cellulosic and Mineral Fiber

Loose-Fill Thermal Insulation                                                           Appendix G Table B-1.2.3

C 1029-08             Specification for Spray-Applied Rigid Cellular Polyurethane

Thermal Insulation                                                                             Appendix G Table B-1.2.3

C 1036-01     Specification for Flat Glass                                                                                                      R4410.2.1.2

C 1048-04     Specification for Heat Treated Flat Glass—Kind HS, Kind FT Coated 7 Uncoated Glass    R4410.2.1.5

C 1053-00     Specification for Borosilicate Glass Pipe and Fittings for Drain, waste and Vent

                      (DWV) Applications                                                                                                            Table R4413.2.2

C 1077         Standard Practice for Laboratories Testing Concrete and Concrete Aggregates for

                     Use in Construction and Criteria for Laboratory Evaluation                                      R4405.2.4, R4405.4.6

C 1158-05             Standard Practice for Use and Installation of Radiant Barrier Systems  N1104.A.3,

(RBS) in Building Construction                                                        Appendix G Table B-1.2.3,

                                                                                                                Appendix G Table C4.2.1.4

C 1224-03             Reflective Insulation for Building Applications                            Appendix G Table B-1.2.3

C 1281- 03 Standard Specification for Preformed Tape Sealants for Glazing Applications ………………………………………..………… R613.8.1.8.1 

ASTM C 1289-08                Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board   Appendix G Table B-1.2.3

ASTM C 1313-05                Sheet Radiant Barriers for Building Construction Applications                 N1104.A.3,          

                                                                                                Appendix G Table B-1.2.3, Appendix G Table C4.2.1.4

ASTM C 1320-05                Standard Practice for Installation of Mineral Fiber Batt and

Blanket Thermal Insulation for Light-Frame Construction        Appendix G Table B-1.2.3

ASTM C 1321-04                Standard Practice for Installation and Use of Interior Radiation                              N1104.A.3

Control Coating Systems (IRCC) in Building Construction        Appendix G Table B-1.2.3

                                                                                                                Appendix G Table C4.2.1.4

ASTM C 1371-04a             Test Method for Determination of Emittance of Materials Near     N1104.A.3, N1104.4

Room Temperature Using Portable Emissometers.                      Appendix G Table B-1.2.3,

                                                                                                                Appendix G Table C4.2.1.4

ASTM C 1549-04                Standard Test Method for Determination of Solar Reflectance Near

Ambient Temperature Using a Portable Solar Reflector              N1104.A.4

D 25-99                      Standard Specification for Round Timber Piles                                                              R4404.7.1

D 41-   05             Specification for Asphalt Primer Used in Roofing, Dampproofing,                    Table R905.9.2,

            and Waterproofing   Table R905.11.2, R4402.3.2.3.2, R4402.6.6.2.4, R4402.8.6, R4402.10.6, R4402.10.14.1

D 43-00  (2006)                   Specification for Coal Tar Primer Used in Roofing, Damproofing and

                                  Waterproofing    Table R905.9.2, R4402.6.6.2.4, R4402.8.6, R4402.10.6, R4402.10.14.2

D 92                          Standard Test Method for Flash and Fire Points by Cleveland Open Cup          R4402.8.2.2

D 226-   06         Specification for Asphalt saturated (Organic Felt) Used in Roofing and           R703.2, R703.9.1,

                                 Waterproofing           R905.2.2, R905.2.3, R905.2.7, R905.4.3, R905.5.3, R905.6.3, R905.8.4,

 R905.8.10.1, Table 905.9.2, R4402.7.4

D 256-03                  Test Methods for Determining Izod Pendulum Impact Resistance of Plastics                R4412.1.2

D 312-00   (2006)     Specification for Asphalt Used in Roofing                            R905.9.2, R4402.8.4, R4402.10.14.1

D 412-98a(2002)el   Test Methods for Vulcanized Rubber and Thermoplastic Elastomers Tension             R4410.6.4

D 624-00el                 Test Methods for Tear Strength of Conventional Vulcanized Rubber and

                                   Thermoplastic Elastomers                                                                                                  R4410.6.4

D 635-03                    Test Methods for Rate of Burning and/or Extent & Time of Burning of Plastics

                                   in a Horizontal Position                                                                                       R4412.1.2

D 1079-02               Standard Terminology Relating to Roofing, Waterproofing and Bituminous Materials R4402.2.1

D 1143-81 (1994) e01  Test Method for Piles Under Static Axial Compressive Load                               R4404.13.1.7

D 1167                     Methods of Testing Asphalt Base Emulsions for Use as Protective

                                 Coatings for Built Up Roofs                                                                                         R4402.12.6.5.2

D 1556                     Standard Test Method for Density of Soil In Place by the Sandcone                           R4404.4.3.2

D 1557-00               Test Method for Laboratory Compaction Characteristics of Soil Using

                                 Modified Effort [56,000 ft lb/ft3 (2700 kN m/m3)]                          R4404.4.3.2

D 1586-99                Specification for Penetration Test and Split Barrel Sampling of Soils                        R4404.18.3.3

D 1621 – 04a                    Standard Test Method for Compressive Properties of Rigid Cellular Plastics 4402.12.6.5.2.17.1

D 1622   -08             Standard Test Method for Apparent Pensity of Rigid Cellular Plastics          R4402.12.6.5.2.17.2

D 1623 -03    Standard Test Method for Tensile and Tensile Adhesion Properties of

                                Rigid Cellular Plastics                                                                                           R4402.12.6.5.2.17.3

D 1693- 08           Test Method for Environmental Stress cracking of Ethylene Plastics                         Table M2101.1

D 1760                     Standard Specification for Pressure Treatment of Timber Products                          Table R4404.7

D 1761-88(2000)el  Test Methods for Mechanical Fasteners in Wood                                                        R4409.1.4.4

D 1861                      Specification for Homogenous Bituminized Fiber Drain Sewer Pipe

                                   (Withdrawn 1992—Replacement)                                                                                         P3002.2

D 1863- 05            Specification for Mineral Aggregate Used in Built up Roofs    Table R905.9.2, Table R906.3.2,

                                                                                                                                                                     R4402.8.12.1

D 1929-96(2001)el   Test Method for Determining Ignition Temperatures of Plastics                                    R4412.1.2

D 2126  -04              Standard Test Method for Response of Rigid Cellular Plastics to Thermal and

                                  Humid Aging                                                                                                      R4402.12.6.5.2.17.4

D 2240—03        Test Method for Rubber Property Durometer Hardness                                                       R4410.6.4

D 2464—06        Specification for Threaded Poly (Vinly Chloride) (PVC) Plastic Pipe Fittings,

                            Schedule 80                                                                                           Table P2904.6, Table R4413.2.7

D 2466—06       Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40           Table P2904.6,

                                                                                                                                                                Table R4413.2.7

D 2467—06       Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80           Table P2904.6,

                                                                                                                                                                Table R4413.2.7

D 2468—96a       Specification for Acrylonitrile Butadiene Styrene (ABS) Plastic Pipe Fittings,

                             Schedule 40                                                             Table P2904.6, Table R4413.2.5, Table R4413.2.7

D 2565—99        Practice for Xeon Arc Exposure of Plastics Intended for Outdoor Applications                  R4412.1.2

D 2609—02(2008)         Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe                Table P2904.6,

                                                                                                                                                               Table R4413.2.7

D 2626—04       Specification for Asphalt saturated and Coated Organic Felt Base Sheet Used

                             in Roofing                                                                                     R905.3.3, Table R905.9.2, R4402.7.4

D 2661—08  Specification for Acrylonitrile Butadiene Styrene (ABS) Schedule 40 Plastic Drain,     Table P3002.1,

                Waste, and Vent Pipe and Fittings Table P3002.2, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4

D 2665—09 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and                  Table P3002.1,

                                Vent Pipe and Fittings              Table P3002.2, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4

D 2677-71(1976)  Method of Test lightability of Barbecue Briquettes (withdrawn no replacement,

                              1985)                                                                                                                         Table R4413.2.4.3

D 2729—03      Specification for Poly (Vinly Cloride)(PVC) Sewer Pipe and Fittings                            Table R4413.2.5

D 2751—  05  Specification for Acrylonitrile Butadiene Styrene (ABS) Sewer Pipe and Fittings   Table P3002.2,

                                                                                                                                                                Table R4413.2.4

D 2797-85(1999)    Standard Practice for Preparing Coal Sampler for Microscopical Analysis by

                                Reflected Light                                                                                                          Table R4413.2.4

D 2842                    Standard Test Method for Water Absorption of Rigid Cellular Plastics          R4402.12.6.5.2.17.6

D 2843—99       Test Method for Density of Smoke from the Burning or Decomposition of Plastics Table R4413.1.2

D 2856                       Standard Test Method for Open Cell Content of Rigid Cellular Plastics by

                                  the Air Pycnometer                                                                                             R4402.12.6.5.2.17.5

D 2898-04   Test Methods for Accelerated Weathering of Fire retardant treated Wood

                           for Fire Testing          R802.1.4.1, R802.1.4.3, R902.2, R4409.1.4.4, R4409.14.4, R4409.16.1

D 2922                     Standard Test Method for Density of Soil and Soil Aggregate In Place by

                                 Nuclear Methods (Shadow Depth)                                                                    R4404.4.3.2

D 2949—01a(2008)    Specification for 3.25 in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Table P3002.1,

                                 Drain, Waste, and Vent Pipe and Fittings                                             Table P3002.2, R4402.5.1,

                                                                                                                                   Table R4413.2.2, Table R4413.2.3

D 3018                     Specification for Class A Asphalt Shingle Surfaced with Mineral Oravies                R4402.12.6.5.1

D 3034— 08        Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

                                                                                                                                                 Table P3002.2, R4413.2.4

D 3201-08a Test Method for Hygroscopic Properties of Fire retardant Wood and Wood base

                               Products                                                                                      R802.1.4.4, R4409.1.4.4, R4409.14.5

D 3441                    Static Cone Soundings                                                                                                   R4404.18.3.3

D 3462- 09    Specification for Asphalt Shingles Made From Glass Felt and Surfaced

                            with Mineral Granules                                                                                     R905.2.4, R4402.12.6.5.1

D 3498-03           Specification for Adhesives for Field Gluing Plywood to Lumber Framing

                            for Floor Systems                                                                                            R4409.1.4.4, R4409.9.1.5

D 3679-09 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding        Table R703.4, R703.11, R703.11.1

D 3746-85(1996)e1 Test Methods for Impact Resistance of Bitumanous Roofing Systems                                     R4402.4.2.4

D 3787-01           Test Method for Bursting Strength of Textiles Constant Rate of Traverse (CRT)

                             Ball Burst Test                                                                                                                 R4101.17.1.15

D 4272—99         Test Method for Total Energy Impact of Plastic Films by Dart Drop                               R4402.4.2.4

D 4402          Viscosity Determinations of Unfilled Asphalt Using the Brookfield Thermostat Apparatus  4402.8.2.3

D 5034—95           Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) Specifications

                               for Adhesives for Field Gluing Plywood to Lumber Framing for Floor Systems     R4101.17.1.15

D 6083—05e01        Specification for Liquid Applied Acrylic Coating Used in Roofing                       Table R905.9.2,

                                                                                                Table R905.11.2, Table R905.15.2, R4402.12.6.2

D 6380—  03 (2009)        Specification for Asphalt Roll Roofing (Organic Felt)                           R905.2.8.2, R905.3.3

ASTM D 6509-00 Specification for Atactic Polypropylene (APP) Modified Bituminous Base Sheet Materials Using Glass Fiber Reinforcements ……………………….Table R905.11.2

D6757- 07         Standard Specification for Underlayment Felt Containing Inorganic Fibers

                               Used in Steep-Slope Roofing                                                             R905.2.2, R905.2.3, R905.2.7

D7158-  07         Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift

                               Force/Uplift Resistance Method)                                                        R905.2.6.1, Table R905.2.6.1

E 84- 09  Test Method for Surface Burning Characteristics of Building Materials                N1110.AB.3.0.7

  R202, R314.3, R314.5.8, R314.5.10, R315.3, R315.4, R316.1, R316.2, R802.1.4, M1601.16, M1601.3.7

                           R4409.1.4.4, R4409.14.1,  R4412.1.2, R4412.1.3.1.1, R4412.1.3.1.4, R4412.1.3.2.4.5,

E 96/E96M-05         Test Method for Water Vapor Transmission of Materials                 M1411.4, M1601.3.4, R202,

                                                                                                 R804.4, R4402.12.6.5.2.17.7, R4409.13.3.2.5

E 108—07a        Test Methods for Fire Tests of Roof Coverings                      R902.1, R902.2, R4402.2.1,

                                                                                                                                  R4402.5.1,

                                                                                                                                         R4402.12.1.2, R4409.16.1

E 119-08a Test Methods for Fire Tests of Building Construction and Materials  R314.1.2, R314.4, R317.1, R317.3.1

                                                                                                                                                                R4412.1.2, R4412.1.3.2

E 136—  09   Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degree C       R202

E 152—95        Methods of Fire Tests of Door Assemblies                                                           R314.3, R4412.1.3.1.4

E 163                Methods of Fire Tests for Window Assemblies (Withdrawn)                                           R4407.4.2.12.8

E 283-04 Standard Test Method for Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen R806.4, , R4409.13.3.2.5,

E 330-02          Test Method for Structural Performance of Exterior Windows, Curtain Walls, and

                         Doors by Uniform Static Air Pressure Difference                    R613.3, R613.4.1, R4410.6.4, R4410.6.6.1

E 331—00(3009)        Test Method for Water Penetration of Exterior Windows, Skylights, Doors and

                         Curtain Walls by Uniform Static Air Pressure Difference                                       R613.4, R4410.6.4

E 903-96                               Test Method for Solar Absorptance, Reflectance, and Transmittance

of Materials Using Integrating Spheres                              N1104.A.4, Appendix G C4.2.1.5

 

E 1300—04e01 or 98 (HVHZ) Practice for Determining Load Resistance of Glass in Buildings  . . . . . . . . . . . . . . . . . . .  R4410.2.2

 

F 405— 05         Specifications for Corrugated Polyethylene (PE) Tubing and Fittings                         Table R4413.2.5

F 409—02(2008)         Specification for Thermoplastic Accessible and Replaceable Plastic Tube and

                            Tubular Fittings                                                                      Table P2701.1, P2702.3, Table R4413.2.7

F 437  06        Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic

                           Pipe Fittings, Schedule 80                                                                      Table P2904.6, Table R4413.2.7

F 438—04          Specification for Socket type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic

                           Pipe Fittings, Schedule 40                                                                      Table P2904.6, Table R4413.2.7

F 439— 06         Specification for Socket type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic

                           Pipe Fittings, Schedule 80                                                                      Table P2904.6, Table R4413.2.7

F 628— 08  Specification for Acrylonitrile Butadiene Styrene (ABS) Schedule 40 Plastic Waste  and Vent Pipe with a Cellular Core Table P3002.1,  Table P3002.2, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4

F 891—07      Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a       Table P3002.1,

                    Cellular Core  Table P3002.2, Table R4413.2.2, Table R4413.2.3, Table R4413.2.4, Table R4413.2.5

F 1346-91(2003)  Performance Specification for Safety Covers and Labeling Requirements for

                                Swimming Pools, Spas and Hot Tubs                                                                                           R202

F 1554—07aStandard Specifications for Anchor Bolts Steel 36, 55 and 105 ksi Yield Strength     Table R4413.2.5

G 26—77            Practice for Operating Light Exposure Apparatus (Xenon Arc Type) With and

                            Without Water for Exposure of Nonmetallic Materials (Withdrawn)                                     R4412.1.2

G 53—96            Practice for Operating Light and Water Exposure Apparatus (Fluorescent UV

                            condensation type) for Exposure of Nonmetallic Materials                                            R4401.17.1.15

G 60                     Standard Practice for Conducting Cyclic Humidity Exposures                                 R4409.6.17.2.2.8

G 85                     Standard Practice for Modified Salt Spray (Fog) Testing                                                      R4402.6.5

 

 

AWPA           American Wood Preservers’ Association

                       801 Alabama Avenue 2nd Floor,                       

                                Selma, AL 36702-0388

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

C2—01            Lumber, Timbers, Bridge Ties and Mine Ties — Preservative Treatment

                         by Pressure Processes                                                       R319.1, R323.1.7, Table R905.8.5, R4409.1.4.5

C3—99            Piles — Preservative Treatment by Pressure Processes      R319.1, R323.1.7, R4404.7.1.3, R4409.1.4.5

C4—99            Poles — Preservative Treatment by Pressure Processes                          R319.1, R323.1.7, R4409.1.4.5

C5—03            Posts—Pressure Treatment by Pressure Processes                                                                  R4409.1.4.5

C6—99            Crossties and Switch Ties Preservative Treatment by Pressure Processes        R4409.1.4.5, R4409.21.9

C7—96            Western Red Cedar, Northern White Cedar & Alaska yellow Cedar Poles Preservative

                         Treatment of Incised Pole Butts by the Thermal process (Withdrawn)                                  R4409.1.4.5

C8—96            Western Red & Alaska Yellow Cedar Poles Preservative Treatment by the Full

                         Length Thermal process (Withdrawn)                                                                                     R4409.1.4.5

C9—03            Plywood — Preservative Treatment by Pressure Processes                     R319.1, R323.1.7, R4409.1.4.5

C10—96          Lodgepole Pine Poles Preservative Treatment by the Full Length Thermal Process             R4409.1.4.5

C11—01          Wood Blocks for Floors & Platforms Pressure Treatment by the Pressure Process               R4409.1.4.5

C14—03          Wood for Highway Construction Pressure Treatment by the Pressure Process                     R4409.1.4.5

C16—03          Wood used on Farms Pressure Treatment                                                                             R4409.1.4.5

C18—99          Standard for Pressure Treated Material in Marine Construction            R319.1, R323.1.7, R4409.1.4.5

C20—99          Structural Lumber—Fire retardant Treatment by Pressure Processes                                   R4409.1.4.5

C22—96          Lumber and Plywood for Permanent Wood Foundations— Preservative Treatment

                         by Pressure Processes                                   R319.1, R323.1.7, R402.1.2, R504.3, R4409.1.4.5

C23—03          Round Poles and Posts Used in Building Construction— Preservative Treatment

                         by Pressure Processes                                                                                    R319.1, 323.1.7, R4409.1.4.5

C25—03           Sawn Crossarms Pressure Treatment                                                                                    R4409.1.4.5

C26—57           Crossarms Non Pressure Treatment                                                                                      R4409.1.4.5

C28—99           Standard for Preservative Treatment by Pressure Process of Structural Glued

                         Laminated Members and Laminations Before Gluing                                                           R4409.1.4.5

C29—01          Lumber to be used for the Harvesting Storage and Transportation of Food Stuffs

                        Preservative Treatment by Pressure Processes                                                                         R4409.1.4.5

M1—01           Standard for the Purchase of Treated Wood Products                                                          R4404.7.1.4

M2—01            Standard for the Inspection of Wood Products Treated with Preservatives                        R4404.7.1.4

M4—08           Standard for the Care of Preservative treated Wood Products                      R4404.7.1.4, R4409.1.4.5

 

 

AWS                American Welding Society

                        550 NW Le Jeune Road

                        Miami, FL 33126

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

B2.1               Standard Welding Procedure and Performance Qualification                                                    R4408.1.3

C5.4               Recommended Welding Practice for Stud Welding                                                                     R4408.1.3

D1.1               Structural Welding Code Steel                                                                                                     R4408.1.3

D1.2               Structural Welding Code Aluminum                                                                                            R4406.1.3

D1.3               Structural Welding Code Sheet Metal                                                                                          R4408.1.3

D1.4               Structural Welding Code Reinforcing Steel                    R4405.4.4, R4405.8.4.8, R4407.2.1.1, R4408.1.3

D9.1               Specification for Welding of Sheet Metal                                                                                    R4408.1.3

D10.9             Standard for Qualification of Welding Procedures and Welders for Piping and Tubing          R4408.1.3

 

 

AWWA         American Water Works Association

                      6666 West Quincy Avenue

                      Denver, CO 80235

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

C110/A21.1.10—03               Standard for Ductile iron and Gray iron Fittings, 3 Inches through 48

                                Inches, for Water                                                                                Table P2904.6, Table R4413.2.7

C511—00               Reduced Pressure Principle Backflow Prevention Assembly                   Table P2902.2, P2902.2.5,

                                                                                                                                    P2902, P2902.4.1

 

CGSB          Canadian General Standards Board

                     11 Laurier Street, Place du Portage III, 6B1

                     Gatineau, Quebec, Canada K1A 1G6

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

37–GP—52M—(1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric R905.12.2, R4402.4.2.4

 

CISPI          Cast Iron Soil Pipe Institute

                     Suite 419

                     5959 Shallowford Road

                     Chattanooga, TN 37421

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

301—04a       Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary  Table P3002.1, Table P3002.2,

                        and Storm Drain, Waste and Vent Piping Applications                      Table R4413.2.2, Table R4413.2.3,

                                                                                                                                   Table R4413.2.4, Table R4413.2.5

 

CPSC         Consumer Product Safety Commission

                    4330 East West Highway

                    Bethesda, MD 20814 4408

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

16 CFR Part 1201—(2002)    Safety Standard for Architectural Glazing        R308.1.1, R308.3, R4410.2.1.3,

                                                                                                                                              R4410.2.3.1.2, R4410.2.4.2

 

CSA            Canadian Standards Association

                     8501 East Pleasant Valley Road

                    Cleveland, OH 44131 5575

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

A257.1—03    Nonreinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings        Table R4413.2.4

A257.2—03    Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings             Table R4413.2.4

B137.2—02   PVC Injection moulded Gasketed Fittings for Pressure Applications   Table P2904.6, Table R4413.2.7

B181.1—02        Plastic Drain and Sewer Pipe Fittings                               Table R4413.2.2, Table R4413.2.3

B181.2—02        PVC Drain, Waste Vent Pipe Fittings                               Table R4413.2.2, Table R4413.2.3

B181.3—02        Polyolefin Laboratory Drainage System                                        Table R4413.2.2, Table R4413.2.3

B182.2—02        PVC Sewer Pipe and Fittings (PSM Type)                                      Table R4413.2.4, Table R4413.2.5

B182.4—02        Profile PVC Sewer Pipe and Fittings                                Table R4413.2.4, Table R4413.2.5

 

DHS/FEMA           Department of Homeland Security

                                Federal Emergency Management Agency

                                Federal Center Plaza

                                500 C Street, SW

                                Washington, DC 20472

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

 

FEMA-TB-2-08  Flood Damage-Resistant Materials Requirements                                                                                                              R322.1.8

FEMA -TB-11—01                        Crawlspace Construction for Buildings Located in Special Flood Hazard Areas                                                   R408.7

 

 

DOC/NIST              Department of Commerce

                                 National Institute of Standards and Technology

                                 100 Bureau Drive Stop 3460

                                 Gaithersburg, MD 20899

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

CS 236              Mat Formed Particleboard                                                                              R4409.1.4.6, R4409.2.1.6

PS 1—  09        Construction and Industrial Plywood R404.2.1, Table R404.2.3, R503.2.1, R604.1, R803.2.1,

                                                        R404.21, Table R404.2.3, R503.2.1, R604.1, R803.2.1, R4409.1.4.6, R4409.2.1.2

PS 2— 10    Performance Standard for Wood–based Structural–use Panels   R404.2.1, Table R404.2.3, R503.2.1,

                                                                                    R604.1, R803.2.1, R404.21, Table R404.2.3, R503.2.1, R604.1,

                                                                                                                                 R803.2.1, R4409.1.4.6, R4409.2.1.2

PS 56                Structural Glued Laminated Timber                                                                                      R4409.1.4.6

PS 20—05       American Softwood Lumber Standard                                    R404.2.1, R502.1.1, R602.1.1, R802.1.1,

                                                                        Table R404.2.3, R503.2.1, R604.1, R803.2.1, R4409.1.4.6, R4409.2.1.8

 

DOL/OSHA       Department of Labor

                           Occupational Safety and Health Administration

                           Frances Perkins Building

                           200 Constitution Avenue, NW

                           Washington, DC 20210

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

29 CFR 1910              General Industry Occupational Health & Safety Standards                                                        R4403.7.3

29 CFR 1926 650(P) Excavation Safety Act                                                                                                                  R4404.1.1

 

FM                Factory Mutual Global Research

                      Standards Laboratories Department

                      1151 Boston Providence Turnpike

                      Norwood, MA 02062

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

4450—(1989)        Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements

                               through July 1992                                                                                           R906.1, R4412.1.3.2.5.2

4470 (1992)            Approval Standard for Class 1 Roof Covers                         R4402.2.1, R4402.4.1.1, R4402.4.2.4

4880—(2005)        American National Standard for Evaluating Insulated Wall or Wall and

                               Roof/Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior

                               Building Panels, Wall/Ceiling Coating Systems, Interior or Exterior

                               Finish Systems                                                                                     R314.4, R314.6, R4412.1.3.1.4

 

FS                 Federal Specification

                      941 Jefferson Davis Highway, Suite 104

                     Arlington, VA 22202

TT P 1536A (1975) Federal Specification for Plumbing Fixture Setting Compound             P3003.4.5

TTC 555B Test Specification for Wind Driven Rain Infiltration Resistance                          R4402.12.6.3.1

 

NAAMM      National Association of Architectural Metal Manufacturers

                      8 South Michigan Avenue

                      Chicago, IL 60603

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

ANSI/NAAMM MBG 5XX   Metal Grating Manual                                                                                        R4408.1.3

 

NFPA         National Fire Protection Association

                    1 Batterymarch Park

                    Quincy, MA 02269

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

259—08 Test Method for Potential Heat of Building Materials. . . . . 2603.4.1.10, 2603.5.3, 2612.3.2.4.4, R314.5.7, R4412.1.3.2.4.4

286—11          Standard Methods of Fire Tests for Evaluating Contribution of Wall and

                        Ceiling Interior Finish to Room Fire Growth                                 R314.4, R314.6, R315.4, R4412.1.3.1.4

 

NRCA           National Roofing Contractors Association

                      10255 W. Higgins Road, Suite 600

                      Rosemont, IL 60018

Standard                                                                                                         Referenced in code

reference number    Title                                                                                           section number

P 0405            Roofing and Waterproofing Manual, 5th Edition                                                                       R4402.2.1

 

RCSC           Research Council on Structural Connections

                      c/o Stanley D. Lindsey & Associates Ltd.

                     224 Metro Center Blvd., Suite 208

                     Nashville, TN 37228-1320

RCSC                     Load and Resistance Factor Design Specification for Structural Joints Using A325 and A490 Bolts, 1988     R4408.1.3

 

SDI             Steel Door Institute

                    P.O. Box 25

                 Fox River Grove, IL 60021

MOC1                    SDI Manual of Construction with Steel Deck                                                R4408.1.3

DDP                        Deck Damage and Penetrations                                                                       R4408.1.3

DDM02                 Diaphragm Design Manual                                                               R4408.1.3, R4408.9.4

SDI, LRFD            Design Manual for Composite Beams and Girders with Steel Deck          R4408.1.3

SPD2                      Standard Practice Details                                                                                   R4408.1.3

NO. 30                   Steel Deck Institute Design Manual                                                                 R4408.1.3

 

SDI           Steel Door Institute

                  c/o Wherry Associates

                  30200 Detroit Road

                  Cleveland, Ohio 44145 1967

ANSI A250.13—03            Testing and Rating of Severe Windstorm Resistant Components for Swinging Door Assemblies       R613.4.4.1

 

SJI             Steel Joist Institute

                   3127 10th Avenue, North

                  Myrtle Beach, SC 29577-6760

SJI          Standard Specifications, Load Tables and Weight Tables for Steel Joists and Joist Girders                     R4408.1.3

SJI          Structural Design of Steel Joist Roofs to Resist Ponding Loads, Technical Digest No. 3       R4408.1.3

SJI          Structural Design of Steel Joist Roofs to Resist Uplift Loads, Technical Digest No. 9           R4408.1.3

SJI          Vibration of Steel Joist Concrete Slab Floors, Technical Digest No. 5       R4408.1.3

SJI          Welding of Open Web Steel, Technical Digest No. 8                                    R4408.1.3

SJI          60 Year Steel Joist Manual                                                                                R4408.1.3

SSPC         Society for Protective Coatings

                   40 24th Street, 6th Floor

                    Pittsburgh, PA 15222-4656

SSPC Paint 15      Steel Joist Shop Paint                                                                                                          R4408.1.3

SSPC/AISC           Guide to the Shop Painting of Structural Steel                                                               R4408.1.3

 

SPRI           Single-Ply Roofing Institute

                     77 Rumford Avenue, Suite 3-B

                      Waltham, MA 02453

Standard                                                                                                              Referenced in code

reference number    Title                                                                                          section number

ES 1-98        Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems                        R903.3

 

STI              Steel Tube Institute of North America (Welded Steel Tube Institute, Inc.)

                    2000 Ponce de Leon, Suite 600

                    Coral Gables, Florida 33134

WSTI/STI             Manual of Cold Formed Structural Steel Tube                                                             R4408.1.3

 

TECO          Timber Company Inc.

                     2402 Daniels Street

                      Madison, WI 53704

PRP 133                Performance Standards and Policies for Structural Use Panels                  R4409.1.4.8, R4409.2.1.2

 

TPI        Truss Plate Institute

               218 N. Lee Street, Suite 312

               Alexandria, VA 22314

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

BCSI  06    Guide to Good Practice for Handling, Installing Restraining & Bracing of Metal Plate           R502.1.3.2, 802.1.6.3,

 

WTCA           Connected Wood Trusses                                            R4409.1.4.9, R4409.6.17.2.4.1, R4409.6.17.2.4.3

TPI 1—02      National Design Standard for Metal plate connected Wood Truss Construction                   R502.1.3.1,

                                                 R502.1.3.2, R802.1.6.2, R802.2.9.1, R4409.1.4.9, R4409.6.17.2.1.1, R4409.6.17.2.2.8

 

UL           Underwriters Laboratories, Inc.

                333 Pfingsten Road

                Northbrook, IL 60062

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

9—00           Standard for Fire Tests of Window Assemblies                                                                    R4407.4.2.12.8

 

 

580—94      Test for Uplift Resistance of Roof Assemblies                                                        R4408.1.3, R4408.9.4.6

790—04      Tests for Fire Resistance of Roof Covering Materials— with Revisions through July 1998   R902.1,

                                                                                                        R4402.2.1, R4402.5.1, R4409.1.4.10, R4402.12.1.2

 

1040—96      Fire Test of Insulated Wall Construction—with Revisions through June 2001               R314.4, R314.6,

                                                                                                                                                                    R4412.1.3.1.4

1715—97       Fire Test of Interior Finish Material                                                          R314.4, R314.6, R4412.1.3.1.4

 

 

DHS/FEMA           Department of Homeland Security

                                Federal Emergency Management Agency

                                Federal Center Plaza

                                500 C Street, SW

                                Washington, DC 20472

Standard                                                                                                              Referenced in code

reference number    Title                                                                                           section number

 

FEMA-TB-2-08 TB-2—93               Flood Damage-Resistant Materials Requirements                                                                                                                   R322.1.8

FEMA FIA-TB-11—01                        Crawlspace Construction for Buildings Located in Special Flood Hazard Areas                                                   R408.7

 

Chapter 44:   Referenced Standards.  Revise to read as follows:

 

High Velocity Hurricane Zone.  Add Chapter 44 from the 2010 Florida Building Code, Residential

 

Chapter 44:  High Velocity Hurricane Zone

 

See Chapter 44 – see HVHZ file

 

Appendix E:  Manufactured housing used as dwellings.  Change to read as follows:

 

Appendix E:  Chapter 9B-53, Standard for Mitigation of Radon in Existing Buildings. 

 

See Appendix E of the 2010 FBCR

 

Appendix F:  Radon control methods.  Change to read as follows:

 

Appendix F:  Chapter 9B-52, Florida Standard for Passive Radon-Resistant New Residential Building Construction.

 

See Appendix F of the 2010 FBCR.