Note: Sections re-numbered to address 2012 IBC
format
Section 1409 1410 High-Velocity Hurricane
Zone Other Materials. Add to read as shown.
Deletion legend:
[1- Default – Not related
to structural wind resistance design]
[2- Fire/Life Safety]
[3- Covered in model base
code]
14010.1 Wood.
14010.1.1 Wood and wood products used for
wall claddings shall comply with Section 2314 through 2330.
14010.1.2 Wood and wood-products used for
wall cladding as non-structural exterior trim, fascia and soffits on buildings
of Type I, II-A and IV. Construction may be applied to the outside of exterior
walls, cornices, architectural appendages, eaves overhangs and similar
projections.
Where an exterior wall is required to be fire resistive,
such material shall be separated from the interior of the building by the
vertical extension of the exterior wall.
[2- Fire/Life Safety]
1409.2 1410.2 Asphalt
shingles. Asphalt shingles shall be applied only to solid wood sheathing
and shall be in tin-capped and spot-stuck, as set forth in Sections 1512
through 1525.
1409.3 1410.3 Roll
slate or felt. Roll slate or felt shall be applied only to solid wood
sheathing and shall be secured by nailing, as set forth in Chapter 15,
High-Velocity Hurricane Zones.
1409.4 1410.4 Metal
shingles. Metal shingles shall be applied only to solid wood sheathing and
shall be secured as set forth in Chapter 15, (High-Velocity
Hurricane Zones).
1409.5 1410.5 Steel
shingles. Steel Siding shall be designed and applied as set forth in
Sections 2214 through 2224.
1409.6 1410.6 Aluminum
siding. Aluminum siding shall be designed and applied as set forth in
Section 2003.
1409.7 1410.7Veneers.
Masonry veneers shall be applied as set forth in Sections 2118 through 2122.
1409.8 Combustible materials. Combustible
materials and fire resistive characteristics of all materials shall comply with
the requirements for the group of occupancy or type of construction, and the
required interior finish rating.
[2- Fire/Life Safety]
1409.9 1410.9 Other
materials. Any cladding materials or assembly not addressed in this code
shall be classified by the building official as the one it most nearly
resembles, and shall comply with the requirements for loading and fire
resistance herein required for such materials and assemblies.