Product Approval Menu > Application Detail
 
FL # FL4537-R2
Application Type Revision
Code Version 2010
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Dixieland Metals of Alabama, LLC.
Address/Phone/Email 378 Eastland Road
Dothan, AL 36304
(334) 678-0038
flvalidation@yahoo.com
 
Authorized Signature Kennon Whaley
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Terrence E. Wolfe
Florida License PE-44923
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 10/17/2024
Validated By Locke Bowden P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL4537_R2_COI_Letter of Certification.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922001
FM 44712010
UL 18972004
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/17/2012
Date Validated 08/22/2012
Date Pending FBC Approval 08/28/2012
Date Approved 10/09/2012
Date Revised 05/27/2015
 
Summary of Products
FL # Model, Number or Name Description
4537.1 26 Ga. PBR Roof Min. 26 Ga. PBR Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +60.0PSF/-47.5PSF
 Other: -47.5 psf @ 5'-0" fastener spacing. +60.0 psf @ 5'-0" o.c. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL4537_R2_II_26 Ga. PBR details.pdf
 Verified By: Terrence E. Wolfe, P.E. 44923
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4537_R2_AE_26 Ga. PBR load table.pdf
 FL4537_R2_AE_26 Ga. PBR Structural Roof Panel NON HVHZ.pdf
 Created by Independent Third Party: Yes
4537.2 26 Ga. Tuff Rib Min. 26 Ga. Tuff Rib Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-96.8PSF
 Other: -96.8 psf @ 2'-0" o.c. fastener spacing. Panel must be install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL4537_R2_II_26 Ga. Tuff Rib details.pdf
 Verified By: Terrence E. Wolfe, P.E. 44923
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4537_R2_AE_26 Ga Tuff Rib load table.pdf
 FL4537_R2_AE_26 Ga. Tuff Rib Structural Roof Panel NON HVHZ.pdf
 Created by Independent Third Party: Yes
4537.3 29 Ga. Tuff Rib Min. 29 Ga. Tuff Rib Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-84.3PSF
 Other: -84.3 psf @ 2'-0" o.c. fastener spacing. Panel must be install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL4537_R2_II_29 Ga. Tuff Rib details.pdf
 Verified By: Terrence E. Wolfe, P.E. 44923
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4537_R2_AE_29 Ga. Tuff Rib load table.pdf
 FL4537_R2_AE_29 Ga. Tuff Rib Structural Roof Panel NON HVHZ.pdf
 Created by Independent Third Party: Yes
 