Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL42380-R0
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Cornerstone Building Brands (MBCI, ABC, UCC, & Reeds)
Address/Phone/Email 5020 Weston Parkway
Cary, NC
(281) 897-7788
Austin.Rentfro@cornerstone-bb.com
 
Authorized Signature Austin Rentfro
Austin.Rentfro@cornerstone-bb.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report David Eng
Florida License PE-81377
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/13/2026
Validated By James R Wally, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL42380_R0_COI_26ga PermaLok on Plywood.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1002023
TAS 1252003
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/30/2023
Date Validated 10/20/2023
Date Pending FBC Approval 11/01/2023
Date Approved 12/13/2023
Date Revised 05/20/2024
 
Summary of Products
FL # Model, Number or Name Description
42380.1 01: Steel PermaLok on plywood 26ga (min) PermaLok on 15/32" (min) plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-63.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_26ga PermaLok on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_26ga PermaLok on Plywood.pdf
 Created by Independent Third Party: Yes
42380.2 02: Aluminum PermaLok on plywood Nominally 0.032 aluminum or thicker PermaLok on 15/32" (min) plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_032 PermaLok on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_032 PermaLok on Plywood.pdf
 Created by Independent Third Party: Yes
42380.3 03: Steel Advantage Lok II plywood or OSB 26ga (min) Advantage Lok II on 15/32" (min) plywood or 7/16" (min) OSB or 3/4 wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-131.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_26ga AdvantageLokII on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_26ga AdvantageLokII on Plywood.pdf
 Created by Independent Third Party: Yes
42380.4 04: Aluminum Advantage Lok II on plywood or OSB Nominally 0.032" or thicker aluminum Advantage Lok II on 15/32" (min) plywood or 7/16" (min) OSB or 3/4 wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_032 AdvantageLokII on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_032 AdvantageLokII on Plywood.pdf
 Created by Independent Third Party: Yes
42380.5 05: Steel Slimline/SL-16 on plywood 26ga (min) Slimline/SL-16 on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_26ga Slimline SL16 on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_26ga Slimline SL16 on Plywood.pdf
 Created by Independent Third Party: Yes
42380.6 06: Steel SL-150 on plywood 24ga (min) SL-150 on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga SL150 on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga SL150 on Plywood.pdf
 Created by Independent Third Party: Yes
42380.7 07: Steel SL-150 on steel deck 24ga (min) SL-150 on 22ga (min) steel B-deck or similar
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-97
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga SL150 on 22ga Deck.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga SL150 on 22ga Deck.pdf
 Created by Independent Third Party: Yes
42380.8 08: Aluminum SL-150 on plywood or OSB Nominally 0.032" aluminum or thicker SL-150 on 15/32" (min) plywood, 7/16" (min) OSB, or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-86
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_032 SL150 on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_032 SL150 on Plywood.pdf
 Created by Independent Third Party: Yes
42380.9 09: Steel SL-175 on plywood 24ga (min) SL-175 on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga SL175 on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga SL175 on Plywood.pdf
 Created by Independent Third Party: Yes
42380.10 10: Steel SL-175 on steel deck 24ga (min) SL-175 on 22ga (min) steel B-deck or similar
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-86
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga SL175 on 22ga Deck.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga SL175 on 22ga Deck.pdf
 Created by Independent Third Party: Yes
42380.11 11: Aluminum SL-175 on plywood Nominally 0.032" aluminum or thicker SL-175 on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_032 SL175 on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_032 SL175 on Plywood.pdf
 Created by Independent Third Party: Yes
42380.12 12: Steel Secure Seam on plywood 24ga (min) Secure Seam on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-101
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga SecureSeam on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga SecureSeam on Plywood.pdf
 Created by Independent Third Party: Yes
42380.13 13: Steel Secure Seam on wood purlins on plywood 24ga (min) Secure Seam on wood purlins (min 1x4) on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-101
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga SecureSeam on 1x4s on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga SecureSeam on 1x4s on Plywood.pdf
 Created by Independent Third Party: Yes
42380.14 14: Aluminum Secure Seam on plywood Nominally 0.032" aluminum or thicker Secure Seam on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_032 SecureSeam on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_032 SecureSeam on Plywood.pdf
 Created by Independent Third Party: Yes
42380.15 15: Steel LokSeam on plywood 24ga (min) LokSeam on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-101
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga LokSeam on Plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga LokSeam on Plywood.pdf
 Created by Independent Third Party: Yes
42380.16 16: Steel LokSeam on steel deck 24ga (min) LokSeam on 22ga (min) steel B-deck or similar
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5
 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al.
Installation Instructions
 FL42380_R0_II_24ga LokSeam on 22ga Deck.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42380_R0_AE_24ga LokSeam on 22ga Deck.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 