42382.1 |
01: Steel DoubleLok on purlins |
24ga (min) DoubleLok on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-220 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24ga DoubleLok on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24ga DoubleLok on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.2 |
02: Steel Mech Seam purlins |
26ga or 24ga (min) Mech Seam on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-135.3 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24ga Mech Seam on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24ga Mech Seam on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.3 |
03: Steel ML200 on purlins |
24ga (min) ML200 on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-120 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24ga ML200 on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24ga ML200 on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.4 |
04: Steel SuperLok on purlins |
24ga or 22ga (min) SuperLok on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-130 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_22-24ga SuperLok on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_22-24ga SuperLok on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.5 |
05: Steel Secure Seam on purlins |
26ga (min) Secure Seam on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-88.4 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_26ga SecureSeam on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_26ga SecureSeam on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.6 |
06: Steel LokSeam on purlins |
24ga (min) LokSeam on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-40 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24ga LokSeam on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24ga LokSeam on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.7 |
07: Steel Rib panel on purlins |
29ga or 26ga (min) Rib panel on 18ga or 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-47.2 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_26-29ga RIB on 16-18ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_26-29ga RIB on 16-18ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.8 |
08: Steel Rib panel on wood purlins |
29ga (min) Rib panel on 1x4 (min) wood purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.9 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_29ga RIB on 1x4 Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_29ga RIB on 1x4 Purlins.pdf Created by Independent Third Party: Yes |
|
42382.9 |
09: Steel 5V on wood purlins |
29ga (min) 5V panel on 1x4 (min) wood purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-70.25 Other: |
Installation Instructions FL42382_R0_II_29ga 5V on 1x4 Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_29ga 5V on 1x4 Purlins.pdf Created by Independent Third Party: Yes |
|
42382.10 |
10: Steel Corrugated on purlins |
26ga or 24ga (min) corrugated panel with nominal 7/8" rib height on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-140 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24-26ga COR on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24-26ga COR on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.11 |
11: Steel 7.2 Panel on purlins |
26ga (min) 7.2 Panel on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_26ga 7.2 Panel on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_26ga 7.2 Panel on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.12 |
12: Steel PBR on purlins |
22ga-29ga PBR on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +96/-163 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_22-29ga PBR on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_22-29ga PBR on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.13 |
13: Steel PBU/M-Panel on purlins |
26ga (min) PBR/M-Panel on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_26ga PBU M Panel on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_26ga PBU M Panel on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.14 |
14: Steel UltraDek on purlins |
24ga (min) UltraDek on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-50 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24ga UltraDek 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24ga UltraDek 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.15 |
15: Steel TS 324 on purlins |
24ga or 22ga (min) TS 324 on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.3 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_22-24ga TS 324 on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_22-24ga TS 324 on 16ga Purlins.pdf Created by Independent Third Party: Yes |
|
42382.16 |
16: Steel BattenLok HS on purlins |
24ga (min) BattenLok HS on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71.2 Other: See evaluation report for details.
| Approval may be used by any of the Cornerstone Building Brands entities, e.g. American Building Components, MBCI, Union Corrugating Company, Reed's Metals, et al. |
Installation Instructions FL42382_R0_II_24ga BattenLok HS on 16ga Purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42382_R0_AE_24ga BattenLok HS on 16ga Purlins.pdf Created by Independent Third Party: Yes |