17419.1 |
Insulated Door |
CP0001/CP0651 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Refer to DWG ES-16-63-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R5_II_ES_10-476_Installation_Instructions_SS.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R5_AE_ES-16-63-CIW.pdf FL17419_R5_AE_Eval_Report_CIW_2020_SD_ISD_SS.pdf Created by Independent Third Party: Yes |
|
17419.2 |
Insulated Door |
CP0001/CP0651 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Refer to DWG ES-16-64-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Impact resistant for 80 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R5_II_ES_10-476_Installation_Instructions_SS.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R5_AE_ES-16-64-CIW.pdf FL17419_R5_AE_Eval_Report_CIW_2020_SD_ISD_SS.pdf Created by Independent Third Party: Yes |
|
17419.3 |
Insulated Door |
CP0001/CP0651 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Refer to DWG ES-16-65-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R5_II_ES_10-476_Installation_Instructions_SS.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R5_AE_ES-16-65-CIW.pdf FL17419_R5_AE_Eval_Report_CIW_2020_SD_ISD_SS.pdf Created by Independent Third Party: Yes |
|
17419.4 |
Non-Insulated Door |
CP0020 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: Refer to DWG ES-16-60-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R5_II_ES_10-476_Installation_Instructions_SS.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R5_AE_ES-16-60-CIW.pdf FL17419_R5_AE_Eval_Report_CIW_2020_SD_ISD_SS.pdf Created by Independent Third Party: Yes |
|
17419.5 |
Non-Insulated Door |
CP0020 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: Refer to DWG ES-16-61-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Impact resistant for 80 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R5_II_ES_10-476_Installation_Instructions_SS.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R5_AE_ES-16-61-CIW.pdf FL17419_R5_AE_Eval_Report_CIW_2020_SD_ISD_SS.pdf Created by Independent Third Party: Yes |
|
17419.6 |
Non-Insulated Door |
CP0020 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +100/-100 Other: Refer to DWG ES-16-62-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R5_II_ES_10-476_Installation_Instructions_SS.pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R5_AE_ES-16-62-CIW.pdf FL17419_R5_AE_Eval_Report_CIW_2020_SD_ISD_SS.pdf Created by Independent Third Party: Yes |