10531.1 |
CBH2.37x5.5, CBH2.37x7.63, CBH2.37x9.75 |
Concealed hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Product has not been evaluated for uplift resistance. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.2 |
DU, DHU, DHUTF series hangers |
Face-mount (DU, DHU) and top-flange (DHUTF) hangers available in widths ranging from 1-9/16" to 3-9/16" and heights ranging from 9-1/8" to 23-15/16". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, fill additional triangular joist nail holes or provide supplemental connectors to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.3 |
HGU3.63-SDS, HGU5.25-SDS, HGU5.50-SDS, HGU5.62-SDS, HGU7.00-SDS, HGU7.25-SDS, HGU9.00-SDS |
Face-mount hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.4 |
HGUS series hangers |
Face-mount hangers available in widths ranging from 1-5/8" to 7-3/8" and heights ranging from 5-5/16" to 12-7/8". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.5 |
HHGU5.25-SDS, HHGU5.50-SDS, HHGU5.62-SDS, HHGU7.00-SDS, HHGU7.25-SDS, HHGU9.00-SDS |
Face-mount hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.6 |
HHUS26-2, HHUS28-2, HHUS210-2, HHUS46, HHUS48, HHUS410, HHUS5.50/10, HHUS7.25/10 |
Face-mount hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.7 |
HSUR, HSUL, HSURC, HSULC series hangers |
Skewed face-mount hangers available in widths ranging from 3-1/8" to 5-1/8" and heights ranging from 4-3/4" to 15-3/4". Concealed flange version (HSURC, HSULC) available for all double 2X and 4X models; only acute flange is concealed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If HSUR or HSUL models with (2) joist nails are used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.8 |
HTU26, HTU28, HTU210, HTU26-2, HTU28-2, HTU210-2 |
Face-mount hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If using HTU26 with (11) 10dx1-1/2" joist nails to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.9 |
HU, HUC series hangers |
Face-mount hangers available in widths ranging from 1-9/16" to 7-1/2" and heights ranging from 2-7/8" to 19-1/4". Concealed flange version (HUC) available for all models having width equal to or greater than 2-9/16". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If HU or HUC models with (2) or (4) 10dx1-1/2" or (2) 10d joist nails are used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.10 |
HUCQ1.81/9-SDS, HUCQ1.81/11-SDS, HUCQ210-2-SDS, HUCQ210-3-SDS, HUCQ310-SDS, HUCQ410-SDS, HUCQ412-SDS, HUCQ5.25/9-SDS, HUCQ5.25/11-SDS, HUCQ610-SDS, HUCQ612-SDS |
Face-mount hangers
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.11 |
HUS, HUSC series hangers |
Face-mount hangers available in widths ranging from 1-5/8" to 3-9/16" and heights ranging from 4-5/16" to 11". Concealed flange version (HUSC) available for models having width equal to or greater than 3-9/16". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.12 |
IUS series hangers |
Face-mount hangers available in widths ranging from 1-7/8" to 3-5/8" and heights ranging from 9-1/4" to 16". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.13 |
LGU3.25-SDS, LGU3.63-SDS, LGU5.25-SDS |
Face-mount hangers
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.14 |
LU24, LU26, LU28, LU210 |
Face-mount hangers
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If using LU24 or LU26 to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.15 |
LUC26Z, LUC210Z |
Face-mount hangers
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.16 |
LUS series hangers |
Face-mount hangers available in widths ranging from 1-9/16" to 4-5/8" and heights ranging from 3" to 10-15/16". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If LUS models with (2) joist nails are used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.17 |
MGU3.63-SDS, MGU5.25-SDS, MGU5.50-SDS, MGU5.62-SDS, MGU7.00-SDS |
Face-mount hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.18 |
MIU series hangers |
Face-mount hangers available in widths ranging from 1-9/16" to 5-1/8" and heights ranging from 6-15/16" to 19-1/2". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If MIU models with (4) joist nails are used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lb. uplift.
|
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.19 |
MUS26, MUS28 |
Face-mount hangers
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |
|
10531.20 |
SUR, SUL, SURC, SULC series hangers |
Skewed face-mount hangers available in widths ranging from 1-9/16" to 3-9/16" and heights ranging from 3-1/16" to 13-3/4". Concealed flange version (SURC, SULC) available for all double 2X and 4X models; only acute flange is concealed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If SUR/L24 or SUR/L26 models are used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. For models with (2) joist nails, fill additional triangular joist nail holes or provide supplemental connectors to achieve minimum 700 lb. uplift. Web stiffeners are required with I-joists when filling triangular joist nail holes. |
Installation Instructions FL10531_R5_II_ESR-2552 (Revised 12-20).pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10531_R5_AE_ESR-2552 (Revised 12-20).pdf |