10856.1 |
DGBF series hangers |
Top flange hangers available in widths ranging from 3-5/8" to 7-1/8" and heights ranging from 9-1/4" to 24". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.2 |
DGF series hangers |
Top flange hangers available in widths ranging from 1-1/2" to 3-5/8" and heights ranging from 7-1/4" to 24". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.3 |
DGHF series hangers |
Top flange hangers available in widths ranging from 1-3/4" to 3-5/8" and heights ranging from 9-1/4" to 24". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.4 |
HUSTF series hangers |
Top flange joist hangers available in widths ranging from 3-1/8" to 3-9/16" and heights ranging from 5-3/8" to 13-1/8". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.5 |
HUTF series hangers |
Top flange hangers available in widths ranging from 1-9/16" to 5-1/2" and heights ranging from 3-7/16" to 15". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If using HU24TF, HU26TF, HU34TF, HU24-2TF, or HU44TF models to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.6 |
JB series hangers |
Top flange hangers available in width of 1-9/16" and heights ranging from 5-3/8" to 7-1/4". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.7 |
JBA series hangers |
Top flange hangers available in width of 1-9/16" and heights ranging from 9-3/16" to 13-1/8". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.8 |
LB series hangers |
Top flange hangers available in width of 1-9/16" and heights ranging from 5-3/8" to 15-1/8". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.9 |
LBAZ series hangers |
Top flange hangers available in width of 1-9/16" and heights ranging from 9-3/16" to 13-1/8". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.10 |
PF, PFB, PFDB, PFDSB series hangers |
Top flange hangers available in width of 1-9/16" and heights ranging from 3-3/8" to 7-1/8". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |
|
10856.11 |
RR |
Ridge rafter connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product has not been evaluated for uplift resistance. Provide additional connection for uplift if needed. If used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. |
Installation Instructions FL10856_R5_II_ESR_2553.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10856_R5_AE_ESR_2553.pdf |