10861.1 |
AHEP |
Adjustable Hip-End Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.2 |
DSC2R-SDS3, DSC2L-SDS3, DSC5R-SDS3, DSC5L-SDS3 |
Drag Strut Connectors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.3 |
GBC |
Gable Brace Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product is designed to resist lateral loads at the gable end wall and has not been evaluated for uplift resistance. |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.4 |
TBE4, TBE6 |
Truss Bearing Enhancer |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When using TBE4 to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lbs uplift resistance. |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.5 |
TC24, TC26, TC28 |
Truss Clip |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lbs uplift resistance. |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.6 |
THJA26, LTHJA26, LTHMA |
Multiple Truss Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: LTHJA26, LTHMA, and some applications of THJA26 provide less than 700 lbs of uplift resistance. If using these to resist wind uplift in the HVHZ, supplemental connectors must be used to achieve 700 lbs uplift resistance. |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.7 |
THJM2-4-SDS3, THJM2-5-SDS3, THJU26, THJU26-W |
Multiple Truss Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: THJM2-4-SDS3, THJM2-5-SDS3, and THJU26-W installed with min. 2x4 hip & jack provide less than 700 lbs of uplift resistance. If using these to resist wind uplift in the HVHZ, supplemental connectors must be used to achieve 700 lbs uplift resistance. |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.8 |
TSBR2-24 |
Truss Spacer-Restraint |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product is designed to provide temporary and permanent bracing for trusses, so it has not been evaluated for uplift resistance.
|
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |
|
10861.9 |
VTCR |
Valley Truss Clip |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lbs uplift resistance. |
Installation Instructions FL10861_R5_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10861_R5_AE_ESR-2605.pdf |