13309.1 |
[VS or VSE or VSS] [_004 or _008 or _099 94] |
Aluminum-clad Deck Mount Venting Skylight, size S06 and smaller (426-H-670.14) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +370/-65 Other: SKG-PG65, max. size 1197mm x 1238mm. PG65 means minimum capacity is 65 psf.
Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _008 variants; with second Lo-E coating for _099 94 variants). |
Certification Agency Certificate FL13309_R4_C_CAC_VS-VSE-VSS [S06 or S01] _004 or _008 or _099 94.pdf Quality Assurance Contract Expiration Date 06/10/2021 Installation Instructions FL13309_R4_II_Additional Anchorage Details.pdf FL13309_R4_II_VS_VSE Installation Instructions.pdf FL13309_R4_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13309.2 |
[VS or VSE or VSS] [_004 or _008 or _099 94] |
Aluminum-clad Deck Mount Venting Skylight, size M08 and smaller (426-H-670.17) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +440/-105 Other: SKG-PG105, max. size 775mm x 1390mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for 2008 variants; with second Lo-E coating for _099 94 variants). |
Certification Agency Certificate FL13309_R4_C_CAC_VS-VSE-VSS [M08 or smaller] _004 or _008 or _099 94.pdf Quality Assurance Contract Expiration Date 06/10/2021 Installation Instructions FL13309_R4_II_Additional Anchorage Details.pdf FL13309_R4_II_VS_VSE Installation Instructions.pdf FL13309_R4_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13309.3 |
[VS or VSE or VSS] [_005 or _099 93] |
Aluminum-clad Deck Mount Venting Skylight, size S06 and smaller
(426-H-670.06) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-90 Other: SKG-PG90, max. size 1197mm x 1238mm. PG90 means minimum capacity is 90 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _099 93 variants). |
Certification Agency Certificate FL13309_R4_C_CAC_VS-VSE-VSS [S06 or S01] _005 or _099 93.pdf Quality Assurance Contract Expiration Date 08/31/2021 Installation Instructions FL13309_R4_II_Additional Anchorage Details.pdf FL13309_R4_II_VS_VSE Installation Instructions.pdf FL13309_R4_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13309.4 |
[VS or VSE or VSS] [_005 or _099 93] |
Aluminum-clad Deck Mount Venting Skylight, size M08 and smaller (426-H-670.11) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +400/-120 Other: SKG-PG120, max. size 778mm x 1391mm. PG120 means minimum capacity is 120 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _099 93 variants). |
Certification Agency Certificate FL13309_R4_C_CAC_VS-VSE-VSS [M08 or smaller] _005 or _099 93.pdf Quality Assurance Contract Expiration Date 08/31/2021 Installation Instructions FL13309_R4_II_Additional Anchorage Details.pdf FL13309_R4_II_VS_VSE Installation Instructions.pdf FL13309_R4_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13309.5 |
[VS or VSE or VSS] 2006 |
Aluminum-clad Deck Mount Venting Skylight, size S06 and smaller (426-H-670.20 and 426-H-670.22) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1197mm x 1238mm. This model was tested for cycling pursuant to ASTM E1886 and ASTM E1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. |
Certification Agency Certificate FL13309_R4_C_CAC_VS-VSE-VSS [S06 or S01] _006.pdf Quality Assurance Contract Expiration Date 08/27/2021 Installation Instructions FL13309_R4_II_Additional Anchorage Details.pdf FL13309_R4_II_VS_VSE Installation Instructions.pdf FL13309_R4_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13309.6 |
[VS or VSE or VSS] 2006 |
Aluminum-clad Deck Mount Venting Skylight, size M08 and smaller (426-H-670.24 and 426-H-670.26) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 775mm x 1390mm. This model was tested for cycling pursuant to ASTM E1886 and ASTM E1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. |
Certification Agency Certificate FL13309_R4_C_CAC_VS-VSE-VSS [M08 or smaller] _006.pdf Quality Assurance Contract Expiration Date 08/27/2021 Installation Instructions FL13309_R4_II_Additional Anchorage Details.pdf FL13309_R4_II_VS_VSE Installation Instructions.pdf FL13309_R4_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |