13326.1 |
HPA28, HPA35 |
Strap style purlin anchors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |
|
13326.2 |
LSTHD8, LSTHD8RJ |
Tie Down Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |
|
13326.3 |
MASA, MASAZ, MASAP, MASAPZ |
Foundation Anchor Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: The "Wind" column should be used unless the load is goverened by the wood strength. When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ when using a 3x4 or 3x6 plate.
|
Installation Instructions FL13326_R4_II_ESR-2555.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2555.pdf |
|
13326.4 |
PA18, PA23, PA28, PA35, PA51, PA68 |
Strap style purlin anchors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |
|
13326.5 |
PAI18, PAI23, PAI28, PAI35 |
Strap style purlin anchors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |
|
13326.6 |
STHD10, STHD10RJ |
Tie Down Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |
|
13326.7 |
STHD14, STHD14RJ |
Tie Down Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |
|
13326.8 |
STHD8, STHD8RJ |
Tie Down Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13326_R4_II_ESR-2920.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13326_R4_AE_ESR-2920.pdf |