13308.1 |
FS [_004, _008 or _099 94] |
Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller
(426-H-672.14) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-70 Other: SKG-PG70, max. size 1137mm x 1175mm.
PG70 means minimum capacity is 70 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _008 variant; with second Lo-E coating for _099 94 variant). |
Certification Agency Certificate FL13308_R4_C_CAC_FS [S06 or S01] _004 or _008 or _099 94.pdf Quality Assurance Contract Expiration Date 09/25/2021 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13308.2 |
FS [_004, _008 or _099 94] |
Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.17) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +350/-105 Other: SKG-PG105, max. size 775mm x 1397mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _008 variant; with second Lo-E coating for _099 94 variant). |
Certification Agency Certificate FL13308_R4_C_CAC_FS [M08 or smaller] _004 or _008 or _099 94.pdf Quality Assurance Contract Expiration Date 09/25/2021 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13308.3 |
FS [_005 or _099 93] |
Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.06) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +400/-45 Other: SKG-PG45, max. size 1137mm x 1175mm.
PG45 means minimum capacity is 45 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _099 93 variant). |
Certification Agency Certificate FL13308_R4_C_CAC_FS [S06 or S01] _005 or _099 93.pdf Quality Assurance Contract Expiration Date 08/19/2021 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13308.4 |
FS [_005 or _099 93] |
Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.11) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +400/-105 Other: SKG-PG105, max. size 781mm x 1397mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _099 93 variant). |
Certification Agency Certificate FL13308_R4_C_CAC_FS [M08 or smaller] _005 or _099 93.pdf Quality Assurance Contract Expiration Date 08/19/2021 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13308.5 |
FS _006 |
Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.20 and -672.22) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1200mm x 1238mm
This model was tested for cycling pursuant to ASTM E 1996 and ASTM E 1886.
Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Both IGU and frame use silicone glass sealant. |
Certification Agency Certificate FL13308_R4_C_CAC_FS [S06 or S01] _006.pdf Quality Assurance Contract Expiration Date 08/25/2021 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13308.6 |
FS _006 |
Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.24 and -672.26) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 781mm x 1397mm.
This model was tested for cycling pursuant to ASTM E 1996 and ASTM E 1886.
Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers.
Both IGU and frame use silicone glass sealant. |
Certification Agency Certificate FL13308_R4_C_CAC_FS [M08 or smaller] _006.pdf Quality Assurance Contract Expiration Date 08/25/2021 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13308.7 |
FSR _004 |
Aluminum-clad Deck Mount Fixed Replacement Skylight, size S06 and smaller (426-H-675.12) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +200/-60 Other: SKG-PG60, max. size 1124mm x 1162mm. PG60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer. |
Certification Agency Certificate FL13308_R4_C_CAC_FSR [S06 or smaller] 2004.pdf Quality Assurance Contract Expiration Date 04/02/2025 Installation Instructions FL13308_R4_II_Additional Anchorage Details.pdf FL13308_R4_II_FSR (Replacement) Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |