Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL13308-R4
Application Type Revision
Code Version 2014
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(864) 377-0691
Mike.rhoden@velux.com
 
Authorized Signature Roger LeBrun
roger.lebrun@velux.com
 
Technical Representative Roger LeBrun
Address/Phone/Email 1418 Evans Pond Road
Greenwood, SC 29649-8725
(864) 941-4828
roger.lebrun@velux.com
 
Quality Assurance Representative Mike Dorn
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648-5001
(864) 941-4700
mike.dorn@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
ASTM E 18862005
ASTM E 19962006
ASTM E 19962005
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 06/19/2015
Date Validated 06/26/2015
Date Pending FBC Approval
Date Approved 07/04/2015
Date Revised 08/02/2017
 
Summary of Products
FL # Model, Number or Name Description
13308.1 FS [_004, _008 or _099 94] Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.14)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +160/-70
 Other: SKG-PG70, max. size 1137mm x 1175mm. PG70 means minimum capacity is 70 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _008 variant; with second Lo-E coating for _099 94 variant).
Certification Agency Certificate
 FL13308_R4_C_CAC_FS [S06 or S01] _004 or _008 or _099 94.pdf
Quality Assurance Contract Expiration Date
 09/25/2021
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.2 FS [_004, _008 or _099 94] Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.17)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +350/-105
 Other: SKG-PG105, max. size 775mm x 1397mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _008 variant; with second Lo-E coating for _099 94 variant).
Certification Agency Certificate
 FL13308_R4_C_CAC_FS [M08 or smaller] _004 or _008 or _099 94.pdf
Quality Assurance Contract Expiration Date
 09/25/2021
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.3 FS [_005 or _099 93] Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.06)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +400/-45
 Other: SKG-PG45, max. size 1137mm x 1175mm. PG45 means minimum capacity is 45 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _099 93 variant).
Certification Agency Certificate
 FL13308_R4_C_CAC_FS [S06 or S01] _005 or _099 93.pdf
Quality Assurance Contract Expiration Date
 08/19/2021
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.4 FS [_005 or _099 93] Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.11)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +400/-105
 Other: SKG-PG105, max. size 781mm x 1397mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _099 93 variant).
Certification Agency Certificate
 FL13308_R4_C_CAC_FS [M08 or smaller] _005 or _099 93.pdf
Quality Assurance Contract Expiration Date
 08/19/2021
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.5 FS _006 Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.20 and -672.22)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1200mm x 1238mm This model was tested for cycling pursuant to ASTM E 1996 and ASTM E 1886. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Both IGU and frame use silicone glass sealant.
Certification Agency Certificate
 FL13308_R4_C_CAC_FS [S06 or S01] _006.pdf
Quality Assurance Contract Expiration Date
 08/25/2021
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.6 FS _006 Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.24 and -672.26)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 781mm x 1397mm. This model was tested for cycling pursuant to ASTM E 1996 and ASTM E 1886. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Both IGU and frame use silicone glass sealant.
Certification Agency Certificate
 FL13308_R4_C_CAC_FS [M08 or smaller] _006.pdf
Quality Assurance Contract Expiration Date
 08/25/2021
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.7 FSR _004 Aluminum-clad Deck Mount Fixed Replacement Skylight, size S06 and smaller (426-H-675.12)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +200/-60
 Other: SKG-PG60, max. size 1124mm x 1162mm. PG60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer.
Certification Agency Certificate
 FL13308_R4_C_CAC_FSR [S06 or smaller] 2004.pdf
Quality Assurance Contract Expiration Date
 04/02/2025
Installation Instructions
 FL13308_R4_II_Additional Anchorage Details.pdf
 FL13308_R4_II_FSR (Replacement) Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe