Product Approval Menu > Application Detail
 
FL # FL6393-R13
Application Type Revision
Code Version 2017
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(864) 377-0691
Mike.rhoden@velux.com
 
Authorized Signature Roger LeBrun
roger.lebrun@velux.com
 
Technical Representative Roger LeBrun
Address/Phone/Email 1418 Evans Pond Road
Greenwood, SC 29649-8725
(864) 941-4828
roger.lebrun@velux.com
 
Quality Assurance Representative Mike Dorn
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648-5001
(864) 941-4700
mike.dorn@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA 101/I.S.2/A4402011
ASTM E18862005
ASTM E19962005
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 11/02/2018
Date Validated 11/28/2018
Date Pending FBC Approval
Date Approved 11/30/2018
Date Revised 09/25/2020
 
Summary of Products
FL # Model, Number or Name Description
6393.1 VELUX Sun Tunnel TSR 0000 TSR 010 size (426-H-626.07)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +200/-180
 Other: TDDCC-PG180; Size tested 254 mm dia (10 in). PG180 means minimum capacity is 180 psf. Dome glazing is minimum 3mm thick. Flashing nails directly to roof deck. Anchorage fasteners provided are 10 ga. galv. ring shank nails.
Certification Agency Certificate
 FL6393_R13_C_CAC_TSR acr - CCL for VELUX 4-25-17.pdf
Quality Assurance Contract Expiration Date
 04/03/2027
Installation Instructions
 FL6393_R13_II_TSR_010_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.2 VELUX Sun Tunnel (14" Commercial) Impact Resistant [TCC 014 or TGC 014 or TMC 014] + [1000] with diffuser: [THC 014 or TOC 014 or TTC 014] + [000*] // With or without an Energy Kit (* denotes 0, 2 or 3) (426-H-707.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. [See following item for Air-water-structural approvals.]
Certification Agency Certificate
 FL6393_R13_C_CAC_TCC_TGC_TMC_14_inch_Commercial_Sun_Tunnel-Impact.pdf
Quality Assurance Contract Expiration Date
 11/29/2021
Installation Instructions
 FL6393_R13_II_TCC_Installation.pdf
 FL6393_R13_II_TGC_TMC_Installation.pdf
 FL6393_R13_II_THC_Diffuser_Installation.pdf
 FL6393_R13_II_TOC_Diffuser_Installation.pdf
 FL6393_R13_II_TTC_Diffuser_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.3 VELUX Sun Tunnel (14" Commercial) Non-Impact [TCC 014 or TGC 014 or TMC 014] + [0000 or 1000] with diffuser: [THC 014 or TOC 014 or TTC 014] + [000*] // With or without an Energy Kit (* denotes 0, 2 or 3) (426-H-707.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-145
 Other: TDDCC/TDDOC-PG145; Max. dia. 356 mm (14 in). PG145 means minimum capacity is 145 psf. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R13_C_CAC_TCC_TGC_TMC_14_inch_Commercial_Sun_Tunnel-NAFS-11.pdf
Quality Assurance Contract Expiration Date
 12/14/2021
Installation Instructions
 FL6393_R13_II_TCC_Installation.pdf
 FL6393_R13_II_TGC_TMC_Installation.pdf
 FL6393_R13_II_THC_Diffuser_Installation.pdf
 FL6393_R13_II_TOC_Diffuser_Installation.pdf
 FL6393_R13_II_TTC_Diffuser_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.4 VELUX Sun Tunnel (22" Commercial) Impact Resistant [TCC 022 or TGC 022] + [5000] with diffuser: [THC 022 or TOC 022 or TTC 022] + [000*] // With or without an Energy Kit (* denotes 0, 2 or 3) (426-H-708.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 559 mm (22 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. [See following item for Air-water-structural approvals.]
Certification Agency Certificate
 FL6393_R13_C_CAC_TCC_TGC_22_inch_Commercial_Sun_Tunnel-Impact.pdf
Quality Assurance Contract Expiration Date
 12/20/2021
Installation Instructions
 FL6393_R13_II_TCC_Installation.pdf
 FL6393_R13_II_TGC_TMC_Installation.pdf
 FL6393_R13_II_THC_Diffuser_Installation.pdf
 FL6393_R13_II_TOC_Diffuser_Installation.pdf
 FL6393_R13_II_TTC_Diffuser_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.5 VELUX Sun Tunnel (22" Commercial) Non-Impact [TCC 022 or TGC 022] + [3000 or 5000] with diffuser: [THC 022 or TOC 022 or TTC 022] + [000*] // With or without an Energy Kit (* denotes 0, 2 or 3) (426-H-708.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-130
 Other: TDDCC/TDDOC-PG130; Max. dia. 559 mm (22 in). PG130 means minimum capacity is 130 psf. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R13_C_CAC_TCC_TGC_22_inch_Commercial_Sun_Tunnel-NAFS-11.pdf
Quality Assurance Contract Expiration Date
 12/20/2021
Installation Instructions
 FL6393_R13_II_TCC_Installation.pdf
 FL6393_R13_II_TGC_TMC_Installation.pdf
 FL6393_R13_II_THC_Diffuser_Installation.pdf
 FL6393_R13_II_TOC_Diffuser_Installation.pdf
 FL6393_R13_II_TTC_Diffuser_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.6 VELUX Sun Tunnel (Residential Curb Mount) Impact Resistant TCR 014 + [1000US or 1000USE0] (426-H-706.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). This model was tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing attaches to site-built curb. Anchorage fasteners provided are black #8 st. stl. pan head screws. [See following item for Air-water-structural approvals.]
Certification Agency Certificate
 FL6393_R13_C_CAC_TCR_14_inch_Residential_Curb_Mount_Sun_Tunnel-Impact.pdf
Quality Assurance Contract Expiration Date
 10/30/2021
Installation Instructions
 FL6393_R13_II_TCR_014_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.7 VELUX Sun Tunnel (Residential Curb Mount) Non-Impact TCR 014 + [0000US, 0000USE0, 0000USE1, 1000US or 1000USE0] (426-H-706.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-165
 Other: TDDCC-PG165; Dia. 356 mm (14 in.) PG165 means minimum capacity is 165 psf. Flashing attaches to site-built curb with eight supplied screws, two per side. Dome glazing is minimum 3mm thick.
Certification Agency Certificate
 FL6393_R13_C_CAC_TCR_14_inch_Residential_Curb_Mount_Sun_Tunnel-NAFS-11.pdf
Quality Assurance Contract Expiration Date
 11/21/2021
Installation Instructions
 FL6393_R13_II_TCR_014_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.8 VELUX Sun Tunnel (Residential) Impact Resistant [TGR, TMF or TMR] + [010 or 014] + [1000 or 1000E0] - and - [TGF 014 or TGF 022] + [1000 or 1000E0] (426-H-705.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 559 mm (22 in.). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. [See following item for Air-water-structural approvals.]
Certification Agency Certificate
 FL6393_R13_C_CAC_TGF_TGR_TMF_TMR_Residential_Sun_Tunnel-Impact.pdf
Quality Assurance Contract Expiration Date
 11/29/2021
Installation Instructions
 FL6393_R13_II_TGF_022_Installation.pdf
 FL6393_R13_II_TGF_TMF_014_Installation.pdf
 FL6393_R13_II_TGR_TMR_THR_014_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.9 VELUX Sun Tunnel (Residential) Non-Impact [TGF, TGR, TMF or TMR] + [010 or 014] + [0000, 0000E0 or E1, 1000 or 1000E0] - and - TGF + [014 or 022] + [0000, 0000E0 or E1, 1000 or 1000E0] (426-H-705.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +300/-125
 Other: TDDCC-PG125; Max. dia. 559 mm (22 in.); PG125 means minimum capacity is 125 psf, uplift and download. Dome glazing is minimum 3 mm thick. Flashing types attach to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws.
Certification Agency Certificate
 FL6393_R13_C_CAC_TGF_TGR_THR_TMF_TMR_Residential_Sun_Tunnel-NAFS-11.pdf
Quality Assurance Contract Expiration Date
 12/18/2021
Installation Instructions
 FL6393_R13_II_TGF_022_Installation.pdf
 FL6393_R13_II_TGF_TMF_014_Installation.pdf
 FL6393_R13_II_TGR_TMR_THR_014_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
6393.10 VELUX Sun Tunnel TLR (Tempered Glass) TLR 014 + [2000A or 2000AE1] (426-H-693.02)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +150/-245
 Other: TDDCC-PG150; Max. tube dia. 356 mm (14 in) - TDD. PG150 means minimum capacity is 150 psf. Exterior glazing is minimum 4mm thick clear tempered glass meeting ASTM E1300. Anchorage fasteners provided: 2.2 mm x 3/4" ring shank nails for alignment on top of roof deck, and #6 pan head sheet metal screws for clamping on underside of deck.
Certification Agency Certificate
 FL6393_R13_C_CAC_TLR_014_Flat_Glass_Top_Sun_Tunnel-NAFS-11.pdf
Quality Assurance Contract Expiration Date
 10/03/2025
Installation Instructions
 FL6393_R13_II_TLR_014_Installation.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 