6393.1 |
VELUX SUN TUNNEL™ TSR 0000 |
TSR 010 size (426-H-626.05) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +400/-210 Other: TDDCC-PG210; Size tested 254 mm dia (10 in). PG210 means minimum capacity is 210 psf. Dome glazing is minimum 3mm thick. Flashing nails directly to roof deck. Anchorage fasteners provided are 10 ga. galv. ring shank nails. |
Certification Agency Certificate FL6393_R10_C_CAC_TSR - CCL for VELUX 2-27-13.pdf Quality Assurance Contract Expiration Date 04/03/2017 Installation Instructions FL6393_R10_II_451389-2013-10_TSR.pdf FL6393_R10_II_TSR Hallmark Supplemental Instr.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.2 |
VELUX SUN TUNNEL™ (14" Commercial) Impact Resistant |
[TCC, TMC or TGC] + 014 + [100*TH or THE0, 100*TO or TOE0, 100*TT or TTE0], where * denotes diffuser 0, 2 or 3 (426-H-707.03) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_14 inch Commercial SUN TUNNEL - Impact.pdf Quality Assurance Contract Expiration Date 11/29/2021 Installation Instructions FL6393_R10_II_453581-2013-12-TCC.pdf FL6393_R10_II_453607-2013-10_TGC-TMC.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.3 |
VELUX SUN TUNNEL™ (14" Commercial) Non-Impact |
[TCC, TMC or TGC] + 014 + [000*TH or THE0, 000*TO
or TOE0, 000*TT or TTE0, 100*TH or THE0, 100*TO or
TOE0, 100*TT or TTE0], where * denotes diffuser 0, 2 or 3
(426-H-707.00) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-150 Other: TDDCC/TDDOC-PG150; Max. dia. 356 mm (14 in).
PG150 means minimum capacity is 150 psf. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_14 inch Commercial SUN TUNNEL - NAFS-11.pdf Quality Assurance Contract Expiration Date 12/14/2021 Installation Instructions FL6393_R10_II_453581-2013-12-TCC.pdf FL6393_R10_II_453607-2013-10_TGC-TMC.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.4 |
VELUX SUN TUNNEL™ (22" Commercial) Impact Resistant |
[TCC or TGC] + 022 + [500*TH or THE0, 500*TO or TOE0, 500*TT or TTE0], where * denotes diffuser 0, 2 or 3 (426-H-708.03) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 559 mm (22 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_22 inch Commercial SUN TUNNEL - Impact.pdf Quality Assurance Contract Expiration Date 12/20/2021 Installation Instructions FL6393_R10_II_453581-2013-12-TCC.pdf FL6393_R10_II_453607-2013-10_TGC-TMC.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.5 |
VELUX SUN TUNNEL™ (22" Commercial) Non-Impact |
[TCC or TGC] + 022 + [300*TH or THE0, 300*TO or TOE0, 300*TT or
TTE0, 500*TH or THE0, 500*TO or TOE0, 500*TT or
TTE0] (426-H-708.00) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-130 Other: TDDCC/TDDOC-PG130; Max. dia. 559 mm (22 in).
PG130 means minimum capacity is 130 psf. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_22 inch Commercial SUN TUNNEL - NAFS-11.pdf Quality Assurance Contract Expiration Date 12/20/2021 Installation Instructions FL6393_R10_II_453581-2013-12-TCC.pdf FL6393_R10_II_453607-2013-10_TGC-TMC.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.6 |
VELUX SUN TUNNEL™ (Residential Curb Mount) Impact Resistant |
TCR 014 + [1000US or 1000USE0] (426-H-706.03) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). This model was tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing attaches to site-built curb. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_Curb Mount Residential SUN TUNNEL - Impact.pdf Quality Assurance Contract Expiration Date 10/30/2021 Installation Instructions FL6393_R10_II_453125-2013-10-TCR_014.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.7 |
VELUX SUN TUNNEL™ (Residential Curb Mount) Non-Impact |
TCR 014 + [0000US, 0000USE0, 1000US or 1000USE0] (426-H-706.00) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-165 Other: TDDCC-PG165; Dia. 356 mm (14 in.)
PG165 means minimum capacity is 165 psf. Flashing attaches to site-built curb with eight supplied screws, two per side. Dome glazing is minimum 3mm thick. |
Certification Agency Certificate FL6393_R10_C_CAC_Curb Mount Residential SUN TUNNEL - NAFS-11.pdf Quality Assurance Contract Expiration Date 11/21/2021 Installation Instructions FL6393_R10_II_453125-2013-10-TCR_014.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.8 |
VELUX SUN TUNNEL™ (Residential) Impact Resistant |
[TGF, TGR, TMF or TMR] + [010, 014 or 022] + [1000 or 1000E0] (426-H-705.03) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 559 mm (22 in.). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_Residential SUN TUNNEL - Impact.pdf Quality Assurance Contract Expiration Date 11/29/2021 Installation Instructions FL6393_R10_II_451635-2013-10-TGF-TMF.pdf FL6393_R10_II_451636-2013-09-TGR-TMR_Low.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.9 |
VELUX SUN TUNNEL™ (Residential) Non-Impact |
[TGF, TGR, TMF or TMR] + [010, 014 or 022] + [0000, 0000E0, 1000 or 1000E0]
(426-H-705.00) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-125 Other: TDDCC-PG125; Max. dia. 559 mm (22 in.); PG125 means minimum capacity is 125 psf, uplift and download. Dome glazing is minimum 3 mm thick. Flashing types attach to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R10_C_CAC_Residential SUN TUNNEL - NAFS-11.pdf Quality Assurance Contract Expiration Date 12/18/2021 Installation Instructions FL6393_R10_II_451635-2013-10-TGF-TMF.pdf FL6393_R10_II_451636-2013-09-TGR-TMR_Low.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.10 |
VELUX SUN TUNNEL™ TLR (Tempered Glass) |
TLR 014 + [2000A or 2000AE1] (426-H-693.02) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +150/-245 Other: TDDCC-PG150; Max. tube dia. 356 mm (14 in) - TDD. PG150 means minimum capacity is 150 psf. Exterior glazing is minimum 4mm thick clear tempered glass meeting ASTM E1300. Anchorage fasteners provided: 2.2 mm x 3/4" ring shank nails for alignment on top of roof deck, and #6 pan head sheet metal screws for clamping on underside of deck. |
Certification Agency Certificate FL6393_R10_C_CAC_TLR 014 2000A or 2000AE1.pdf Quality Assurance Contract Expiration Date 10/03/2025 Installation Instructions FL6393_R10_II_453987-2015-06-TLR.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |