Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL13560-R4
Application Type Revision
Code Version 2014
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(864) 377-0691
Mike.rhoden@velux.com
 
Authorized Signature Roger LeBrun
roger.lebrun@velux.com
 
Technical Representative Roger LeBrun
Address/Phone/Email 1418 Evans Pond Road
Greenwood, SC 29649-8725
(864) 941-4828
roger.lebrun@velux.com
 
Quality Assurance Representative Mike Dorn
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648-5001
(864) 941-4700
mike.dorn@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
ASTM E 18862005
ASTM E 19962005
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 06/19/2015
Date Validated 06/26/2015
Date Pending FBC Approval
Date Approved 07/05/2015
Date Revised 08/02/2017
 
Summary of Products
FL # Model, Number or Name Description
13560.1 [VCE or VCM or VCS] + [2004 or 2008 or 2099 94] Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 4646 and smaller (426-H-695.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +230/-45
 Other: SKG-PG45, max. size 1305mm x 1305mm. PG45 means minimum capacity is 45 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for 2008 variant; with second Lo-E coating for 2099 94 variant). Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R4_C_CAC_VCE-VCM-VCS [4646 or smaller] 2004 or 2008 or 2099 94.pdf
Quality Assurance Contract Expiration Date
 03/20/2020
Installation Instructions
 FL13560_R4_II_453525-2013-08_VCS.pdf
 FL13560_R4_II_VCM_VCE Installation Instructions w Underlayment.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13560.2 [VCE or VCM or VCS] + [2005 or 2099 93] Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 4646 and smaller (426-H-695.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +230/-30
 Other: SKG-PG30, max. size 1305mm x 1305mm. PG30 means minimum capacity is 30 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered; (with second Lo-E coating for 2099 93 variant). Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R4_C_CAC_VCE-VCM-VCS [4646 or smaller] 2005 or 2099 93.pdf
Quality Assurance Contract Expiration Date
 03/20/2020
Installation Instructions
 FL13560_R4_II_453525-2013-08_VCS.pdf
 FL13560_R4_II_VCM_VCE Installation Instructions w Underlayment.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13560.3 [VCE or VCM or VCS] + 2006 Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 4646 and smaller (426-H-695.06 and -695.08)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50, max. size 1305mm x 1305mm. Tested pursuant to ASTM E 1886 and ASTM E 1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R4_C_CAC_VCE-VCM-VCS [4646 or smaller] 2006.pdf
Quality Assurance Contract Expiration Date
 03/14/2020
Installation Instructions
 FL13560_R4_II_453525-2013-08_VCS.pdf
 FL13560_R4_II_VCM_VCE Installation Instructions w Underlayment.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe