FL # FL11470-R4
Application Type Revision
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Simpson Strong-Tie Company
Address/Phone/Email 2151 S. Airport Drive
McKinney, TX 75069
(800) 999-5099   Ext 3131
crizer@strongtie.com
 
Authorized Signature Keith Cullum
kcullum@strongtie.com
 
Technical Representative Keith Cullum
Address/Phone/Email 2221 Country Lane
McKinney, TX 75069
(800) 999-5099   Ext 3027
kcullum@strongtie.com
 
Quality Assurance Representative Shelby Short
Address/Phone/Email 5956 W. Las Positas Boulevard
Pleasanton, CA 94588
(800) 999-5099
sshort@strongtie.com
 
Category Structural Components
Subcategory Wood Connectors
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Jeffrey Arneson, P.E.
Florida License PE-58544
Quality Assurance Entity Benchmark Holdings, L.L.C.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Ted Berman, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11470_R4_COI_Arneson Cert of Independence 2017-10-06.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AISI S1002012
ANSI/AWC NDS2015
ASTM D71472005
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/06/2017
Date Validated 10/20/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
 
Summary of Products
FL # Model, Number or Name Description
11470.1 CCCQ-SDS2.5, CCTQ-SDS2.5, ECCLQ-SDS2.5 Multi-member Column Caps
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum, P.E. 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
11470.2 H16, H16S, H16-2, H16-2S Hurricane Tie
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum, P.E. 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
11470.3 HRS6, HRS8, HRS12 Heavy Straps
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Two straps are required to achieve min. 700 lbs when using HRS6 to resist uplift in HVHZ.
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum, P.E. 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
11470.4 HTSQ16Z, HTSQSS, HTSQ20Z, HTSQSS Twist Strap
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
11470.5 ML24Z, ML24SS, ML26Z, ML26SS Heavy Angles
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum, P.E. 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
11470.6 MTS24C, MTS30C Twist Straps
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum, P.E. 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
11470.7 TSP Twisted Stud-Plate Tie
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Multiple/additional connectors are required to achieve min. 700 lbs in HVHZ when connecting stud to single sill plate, and when connecting SPF stud to top plate with 10d X 1-1/2" nails to plate.
Installation Instructions
 FL11470_R4_II_SIM201702 Sealed 2017-10-19.pdf
 Verified By: Keith Cullum, P.E. 76846 (CA)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11470_R4_AE_SIM201702 Sealed 2017-10-19.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe