4149.1 |
26 Ga. PBR |
Min. 26 Ga. PBR Roof Panel over Min. 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-56.75PSF Other: -56.75 psf @ 24" o.c fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL4149_R2_II_Min. 26 Ga. PBR Panel over plywood details.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4149_R2_AE_26 Ga. PBR Panel over .5 Plywood NON HVHZ.pdf FL4149_R2_AE_Min. 26 Ga. PBR Panel over plywood load table.pdf Created by Independent Third Party: Yes |
|
4149.2 |
26 Ga. Snap Lock |
1 3/4" Snap Lock Min. 26 Ga. 14" Wide Roof Panel over Min. 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-64.25PSF Other: -64.25 psf @ 24" o.c. clip spacing. Install per manfacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL4149_R2_II_1.75 Snap Lock Details.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4149_R2_AE_1.75 Snap Lock Load Table.pdf FL4149_R2_AE_26 Ga. 1.75 Snap Lock over .5 Plywood NONHVHZ.pdf Created by Independent Third Party: Yes |
|
4149.3 |
26 Ga. Tuff Rib |
Min. 26 Ga. Tuff Rib over Min. 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-146.0PSF Other: -86.75 psf @ 24" o.c. fastener pattern Type A. -146.0 psf @ 12" o.c. fastener pattern Type B. Panel must be installed per the manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL4149_R2_II_26 Ga. Tuff Rib Details.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4149_R2_AE_26 Ga. Tuff Rib load Table.pdf FL4149_R2_AE_26 Ga. Tuff Rib Panel over .5 Plywood NON HVHZ.pdf Created by Independent Third Party: Yes |