4149.1 |
26 Ga. PBR |
Min. 26 Ga. PBR Roof Panel over Min. 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-56.75PSF Other: -56.75 psf @ 24" o.c fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL4149_R3_II_Details 2.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4149_R3_AE_Dixieland 4149_ss.pdf Created by Independent Third Party: Yes |
|
4149.2 |
26 Ga. Snap Lock |
1 3/4" Snap Lock Min. 26 Ga. 14" Wide Roof Panel over Min. 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-64.25PSF Other: -64.25 psf @ 24" o.c. clip spacing. Install per manufacturers details and in compliance with FBC 2014.
Not for use in HVHZ Zones. |
Installation Instructions FL4149_R3_II_Details 2.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4149_R3_AE_Dixieland 4149_ss.pdf Created by Independent Third Party: Yes |
|
4149.3 |
26 Ga. Tuff Rib/29Ga. Tuff Rib |
Min. 26 Ga. Tuff Rib over Min. 15/32" APA Plywood/ 29Ga. Tuff Rib over 1x4 SYP wood purlins over shingles(optional) over 15/32" APA plywood. Not for use in HVHZ. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-146.0PSF Other: 26Ga.-86.75 psf @ 24" o.c. fastener pattern Type A. -146.0 psf @ 12" o.c. fastener pattern Type B. 29Ga.-45psf@24"o.c and -157.5psf@12"o.c. Panels must be installed per the manufacturers details and in compliance with FBC 2014. Not for use in HVHZ Zones. |
Installation Instructions FL4149_R3_II_Details 2.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4149_R3_AE_Dixieland 4149_ss.pdf Created by Independent Third Party: Yes |