10999.1 |
7/8" Corrugated Panel |
Min. 24 ga., 32" wide coverage through fastened roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.4 Other: Uplift load of 79.7 psf at support spacing of 60" o.c. and 156.4 psf at support spacing of 24" o.c. |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_1.pdf Created by Independent Third Party: Yes |
|
10999.2 |
Aluminum Magna-Loc |
Min. 0.032" thick, 16" wide standing seam roof panel with standard clip over open supports or deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105 Other: Uplift load of 30.0 psf at clip spacing of 60" o.c. and 87.5 psf at clip spacing of 12" o.c. for 0.032" thick panel and uplift load of 41.0 psf at clip spacing of 60" o.c. and 105.0 psf at clip spacing of 12" o.c. for 0.040" thick panel |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_2.pdf Created by Independent Third Party: Yes |
|
10999.3 |
Classic Rib |
Min. 26 ga., 36" wide, through fastened panel over open steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.7 Other: Uplift load of 61.2 psf at fastener spacing of 48" o.c. and 138.7 psf at fastener spacing of 24" o.c. |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_3.pdf Created by Independent Third Party: Yes |
|
10999.4 |
Classic Rib |
Min 29 ga., 36" wide, through fastened panel over open wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-128.3 Other: Uplift load of 128.3 psf at fastener spacing of 24" o.c. |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_4.pdf Created by Independent Third Party: Yes |
|
10999.5 |
Magna-Loc |
Min. 24 ga., 16" wide standing seam roof panel with standard clip over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.7 Other: Uplift load of 51.0 psf at clip spacing of 60" o.c. for 24 ga. panel, 73.7 psf at clip spacing of 60" o.c. for 22 ga. panel and 146.7 psf at clip spacing of 12" o.c. for minimum 24 ga. panel. |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_5.pdf Created by Independent Third Party: Yes |
|
10999.6 |
Magna-Loc 180 |
Min. 24 ga., 16" wide standing seam roof panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-117.7 Other: Uplift load of 39.6 psf at clip spacing of 60" o.c. and 117.7 psf at clip spacing of 12" o.c. |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_6.pdf Created by Independent Third Party: Yes |
|
10999.7 |
PBR-Panel |
Min. 26 ga., 36" wide, through fastened panel over open steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.4 Other: Uplift load of 41.9 psf at fastener spacing of 60" o.c. and 154.4 psf at fastener spacing of 24" o.c. |
Installation Instructions FL10999_R3_II_EvaluationReportC2180_7.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_7.pdf Created by Independent Third Party: Yes |
|
10999.8 |
Seam-Loc 24 |
24 or 22 ga., max 24" wide standing seam roof panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-74.1 Other: For 24 ga. panel, uplift load of 37.9 psf at clip spacing of 60" o.c. and 69.8 psf at clip spacing of 24" o.c.
For 22 ga. panel, uplift load of 44.2 psf at clip spacing of 60" o.c. and 74.1 psf at clip spacing of 24" o.c.
|
Installation Instructions FL10999_R3_II_EvaluationReportC2180_8.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_8.pdf Created by Independent Third Party: Yes |
|
10999.9 |
Seam-Loc 24 with Clamps |
Min. 24 ga., max. 24" wide standing seam roof panel with S-5! clamps over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-130.9 Other: Uplift load of 53.5 psf at clip spacing of 60" o.c. and 130.9 psf at clip spacing of 24" o.c.
|
Installation Instructions FL10999_R3_II_EvaluationReportC2180_9.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL10999_R3_AE_EvaluationReportC2180_9.pdf Created by Independent Third Party: Yes |