9482.1 |
7/8" Corrugated Panel |
Min 24 ga., 34.67" wide coverage through fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +175/-175 Other: Allowable positive and negative design load of 30 psf at support spacing of 96" o.c. and 175 psf at support spacing of 24" o.c. |
Installation Instructions FL9482_R5_II_EvaluationReportC2179_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9482_R5_AE_EvaluationReportC2179_1.pdf Created by Independent Third Party: Yes |
|
9482.2 |
Classic Rib |
Min 26 ga., 36" wide wall panel fastened to steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +110/-110 Other: Allowable positive and negative design load of 110 psf at support spacing of 24" o.c. and 30 psf at support spacing of 48" o.c. |
Installation Instructions FL9482_R5_II_EvaluationReportC2179_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9482_R5_AE_EvaluationReportC2179_2.pdf Created by Independent Third Party: Yes |
|
9482.3 |
Classic Rib |
Min 29 ga., 36" wide wall panel fastened to wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Allowable positive and negative design load of 120 psf at support spacing of 24" o.c. |
Installation Instructions FL9482_R5_II_EvaluationReportC2179_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9482_R5_AE_EvaluationReportC2179_3.pdf Created by Independent Third Party: Yes |
|
9482.4 |
R-Panel or PBR-Panel |
Min 26 ga., 36" wide wall panel fastened to steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Allowable positive and negative design load of 120 psf at support spacing of 24" o.c. and 45 psf at support spacing of 60" o.c. |
Installation Instructions FL9482_R5_II_EvaluationReportC2179_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9482_R5_AE_EvaluationReportC2179_4.pdf Created by Independent Third Party: Yes |
|
9482.5 |
Soffit Panel |
Min 24 ga., 12" wide, wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +55/-55 Other: Allowable positive and negative design load of 55 psf at support spacing of 48" o.c. |
Installation Instructions FL9482_R5_II_EvaluationReportC2179_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9482_R5_AE_EvaluationReportC2179_5.pdf Created by Independent Third Party: Yes |
|
9482.6 |
Span-Line 36A |
Min 26 ga., 36" wide wall panel fastened to steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +110/-110 Other: Allowable positive and negative design load of 110 psf at support spacing of 24" o.c.and 40 psf at support spacing of 48" o.c. |
Installation Instructions FL9482_R5_II_EvaluationReportC2179_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9482_R5_AE_EvaluationReportC2179_6.pdf Created by Independent Third Party: Yes |