FL # FL7271-R4
Application Type Revision
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 813-2432
rblake@unioncorrugating.com
 
Authorized Signature Randy Blake
rblake@unioncorrugating.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL7271_R4_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922005
FM 44702012
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/03/2017
Date Approved 12/12/2017
Date Revised 10/10/2020
 
Summary of Products
FL # Model, Number or Name Description
7271.1 2-1/2" Corrugated Panel Min 26 ga., 24" wide through fastened panel with coverage width of 21-1/4"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-129.25
 Other: Uplift load of 129.25 psf @ fastener spacing of 24" o.c. over 19/32" thick plywood
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_1.pdf
 Created by Independent Third Party: Yes
7271.2 5V Min 26 ga., 24" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-66.3
 Other: Uplift load of 66.3 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_2.pdf
 Created by Independent Third Party: Yes
7271.3 5V Min 26 ga., 24" wide through fastened panel over 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-120.9
 Other: Uplift load of 120.9 psf @ fastener spacing of 24" o.c. for Fastener Pattern 1. Uplift load of 85.8 psf @ fastener spacing of 24" o.c. and 113.1 psf @ fastener spacing of 12" o.c. for Fastener Pattern 2.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_3.pdf
 Created by Independent Third Party: Yes
7271.4 5V Min 29 ga., 24" wide through fastened panel over 15/32" thick plywood or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_4.pdf
 Created by Independent Third Party: Yes
7271.5 5V Min 26 ga., 24" wide through fastened panel over 15/32" or 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-150
 Other: Uplift load of 150 psf in 19/32" thick plywood for Fastener Pattern 2
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_5.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_5.pdf
 Created by Independent Third Party: Yes
7271.6 MasterRib Min 29 ga., 36" wide through fastened panel over nom. 1" x 4" furring and 15/32" thick plywood or 7/16" thick OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114
 Other: Uplift load of 71 psf for Fastener Pattern 1 & 114 psf for Fastener Pattern 2
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_6.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_6.pdf
 Created by Independent Third Party: Yes
7271.7 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-113.1
 Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. & 113.1 psf @ fastener spacing of 12" o.c.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_7.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_7.pdf
 Created by Independent Third Party: Yes
7271.8 MasterRib Min 26 ga., 36" wide through fastened panel over 19/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114.3
 Other: Uplift load of 61.8 psf @ fastener spacing of 30" o.c. and 114.3 psf @ fastener spacing of 24" o.c.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_8.pdf
 Verified By: Bala Sockalingam 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_8.pdf
 Created by Independent Third Party: Yes
7271.9 ML200 Min 24 ga., max 16" wide standing seam metal panel with double lock seam over metal deck.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0
 Other: Uplift load of 71.0 psf @ clip spacing of 36" o.c. and 116.0 psf @ clip spacing of 12" o.c.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_9.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_9.pdf
 Created by Independent Third Party: Yes
7271.10 SL175 Min 24 ga., max 16" wide snap-lock standing seam metal panel over metal deck.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-86.0
 Other: Uplift load of 63.5 psf @ clip spacing of 36" o.c. and 86.0 psf @ clip spacing of 12" o.c.
Installation Instructions
 FL7271_R4_II_EvaluationReportC2174_10.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7271_R4_AE_EvaluationReportC2174_10.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe