Description:
Th property has mixed use R1/R2, consists of 32 units.
1st floor will have 6 hotel rooms and 6 apartments,
2nd floor will have 1 hotel room and 7 apartments,
3rd floor will have 11 hotel rooms.
Construction Cost:
Summary:
Cost of rehab is expected to be around $700,000. We are waiting on the plans approval to start fully rehabbing the property. The property will require full rehab and the CRA department granted $50,000 towards the exterior expenses.For any further information you may contact:Christopher Crocitto, Project Manager
Hollywood Community Redevelopment Agency
Hollywood, FL 33020, 954-924-2980
CCROCITTO@hollywoodfl.org
*Briefly explain why the request has now been referred to the Commission.
As per chief of building department Russell Long, the owners were told to contact the Bureau of Historic Preservation with the state of Florida to request a ruling that the ADA requirements can be removed.
Requirements to be Waived.
Issue 1:
Florida-specific hotel/motel rooms
Minimum height in parking structures
Accessible parking
Vertical accessibility
Toilet rooms
Private
Other
The existing Historical wood stair of the building located at the lobby and is at the core of the building has been requested by the City of Hollywood to be brought up to the 2020 Florida Accessibility Code, with risers not exceeding 7” and stair treads at 11” minimum. Presently, the existing stair is non-compliant to the present 2020 Florida Building Code with existing stair treads at 10”. Bringing the original wood stair up to today’s Building Code, would require us to remove the original Historic Stair at each of the 3 Floors, and replace it with a longer new stair creating headroom issues, as well as not fitting within the existing building envelope, thereby destroying and threatening the Historical significance of the building.
Issue 2:
Florida-specific hotel/motel rooms
Minimum height in parking structures
Accessible parking
Vertical accessibility
Toilet rooms
Private
Other
Need Additional Space
Issue 3:
Florida-specific hotel/motel rooms
Minimum height in parking structures
Accessible parking
Vertical accessibility
Toilet rooms
Private
Other
The City of Hollywood is requesting to reflect accessible routes within the interior and exterior of the building, and due to the building’s split-level design, it makes this accommodation impossible and would destroy the Historic significance of the building.
The building originally was built along the north and west property lines making it impossible to add a lift or an elevator on the exterior façade along those two sides.