Required Fields* |
Form #: FBCED 2003-03
Rule #: 9B-70.002(3)
Effective Date: September 10, 2010 |
FBC Course # |
256.1 |
Course Accreditor* |
Bill Dumbaugh |
Course Title* |
Building/Structural Summary |
Building Code Version* |
2007 |
Delivery Format |
Online |
Short Course Description* |
Overview of Changes from the 2001 Building Code |
Author of Course* |
Department of Community Affairs |
# of hours* |
1 |
|
Subject/Trade Area (Select one or more areas) |
Building – Commercial |
Building – Residential |
|
|
Method of Presentation (Select one or more methods) |
|
|
Supporting Documentation |
Course Syllabus* |
Date |
Attached File |
12/14/2010 |
256-1-SYLLABUS-Advanced Building Code Structural Course.pdf |
|
|
|
|
|
|
Course Materials |
Date |
Attached File |
12/29/2010 |
256-1-MATERIAL-Advanced- 2007 FBC- BLDG-UpdateSummary.pdf |
|
|
|
|
|
|
Detailed Course Outline |
Date |
Attached File |
12/14/2010 |
256-1-OUTLINE-Advanced Building Code Structural Course.pdf |
|
|
|
|
|
|
Detailed Course Timeline |
Date |
Attached File |
12/14/2010 |
256-1-TIMELINE-Advanced Building Code Structural Course.pdf |
|
|
|
|
|
Learning Objectives |
Date |
Attached File |
12/14/2010 |
256-1-OBJECTIVES-Advanced Building Code Structural Course.pdf |
|
|
|
|
|
|
History |
Date Submitted |
12/29/2010 |
Date Approved |
|
Date Last Updated |
|
Date Expires |
|
|
More Information |
Request |
Date Request |
Provider Responses |
Due Date For Response |
Attached File |
Please upload current course materials for course renewal. |
12/23/2010 |
Resubmitted with changes |
01/13/2011 |
|
The pages of the powerpoint are not numbered so I will use the code sections that are referenced to identify where there are corrections necessary. 1. Section 909.4.7 Smoke Control Systems should be Section 909.4.6 2. 909.20.5 should say 0.05 inch of water column, not 0.5 3. 1013.3 this exception is for R-2 and R-3 only and does not require the rails to be attached to the treads. 4. 1504.8 This section does not prohibit the use of gravel or stone. Gravel or stone are allowed on roof pitches of 3:12 or less. 5. 1609.5, the section was not deleted, only the information in it was deleted. It is now "Roof Systems". 6. 1609.6, the section was not deleted, only the information in it wasdeleted. It is now "Garage Doors and Rolling Doors" 7. 2211 should be Section 2210. |
12/27/2010 |
Tim said that you would nail him on this when he sees you! |
01/17/2011 |
|
here are still 2 corrections not made 909.20.5 still says 0.5 inches of water colums and should say 0.05 inches 2. 1008.1.9 still says 120 amperes and should asy 1200 amperes Everything else was corrected. |
12/29/2010 |
Thanks very much Mr. Dumbaugh |
01/19/2011 |
|
|
|
|