FLORIDA BUILDING COMMISSION

Structural Technical Advisory Committee 

MINUTES

Monday, February 2, 2009
2:30 PM- 3:15

Crowne Plaza Melbourne Oceanfront Hotel
2605 N AIA Highway , Melbourne FL

1-800-980-6429 or 321-777-4100

1.  Revised and approved agenda to remove item No. 3.  Minutes were approved as submitted.

Structural TAC:……………………………………………………………… Paul Kidwell, Chairman
Craig Parrino, C.W. Macomber, Dave Olmstead, Jim Schock, Rusty Carroll, Jack Glenn, Bill Dumbaugh (for Dan Lavrich), Do Kim, Jaime Gascon.

2. Review and provide recommendations to the Commission on the request for declaratory statements:

DCA08-DEC-194 by Dan Arlington, Plans Examiner, St. Johns County Building Department – From December 2008 Meeting

Question 1:  The draft 2007 FBC, Section 1609.4.3 Exposure C requires a 20% increase in roof sheathing uplift and roof to wall uplift loads, in certain wind exposures.

 

Is it the intent of 1609.4.3 to increase the entire continuous uplift path by 20%?

 

Answer:  No.  In accordance with Section 1604.9 of the 2007 FBC, Building, the 20% increase is limited to components and cladding roof sheathing uplift and roof-to-wall uplift loads. 

 

Question 2:  If “Yes” to question 1, is it the intent to increase the load capacity of roof trusses by 20%?

 

Answer:  See answer to question 1

3.  Petition by Power Steel Corporation to revoke FL# 158 was not discussed by the TAC due to the fact that the POC did not request any further discussion on the subject.

4.  Public Comment – Robert Van Becelaere of Ruskin Air and Sound Control provided the TAC with information regarding standards ANSI/AMCA Standard 540-08 (Test Method for Louvers Impacted by Windborne Debris) and AMCA Standard 550-08 (Test Method for High Velocity Wind Driven Rain Resistant Louvers) for future consideration in the 2010 Code.

 

With no further business and comments from the committee, it was Adjourned at 3:15

Note: This document is available to any person requiring materials in alternate format upon request. Contact the Department of Community Affairs, 2555 Shumard Oak Boulevard , Tallahassee , Florida , 32399-2100 or call 850-487-1824 

This Document prepared by the Florida Department of Community Affairs
Joe Bigelow – joe.bigelow@dca.state.fl.us  850-922-9160
Manager – Mo Madani – mo.madani@dca.state.fl.us  850-921-2247