Comment 3 DOH - Staff
2007
Chapter 4 Special detailed requirements based on use and occupancy
Revise section 424.1 to read as follows:
424.1 Public swimming pools and bathing places. Public swimming pools and bathing places shall comply with the design and construction standards of this section.
NOTE: Other administrative and programmatic provisions may
apply. See Department of Health (DOH) Rule 64E-9,
"Bathing load" means the maximum number of persons allowed in the pool or bathing place
at one time.
"Collector tank" means a reservoir, with a minimum of 2.25 square feet water surface area
open to the atmosphere, from which the recirculation or feature pump takes
suction, which receives the gravity flow from the main drain line and surface
overflow system or feature water source line, and that is cleanable.
“Effective Barrier” – A barrier which consists of a building, or
equivalent structure, plus a 48 inch minimum height fence on the remaining
sides or a continuous 48 inch minimum height fence. All access through the
barrier must have one or more of the following safety features: alarm, key lock
or self-locking doors and gates. Safety covers that comply with the American
Society for Testing Materials standard F1346-91 (2003)
may also be considered as an
effective barrier.
“D.E.” – is the Diatomaceous Earth
that is used as a filter aid in DE type filters. For the purpose of this rule,
it also includes alternative filter aids that have been approved under NSF/ANSI
Standard 50-2007, and accepted by the filter manufacturer.
"Interactive water features" means a structure designed to allow for recreational activities with recirculated, filtered, and treated water; but having minimal standing water. Water from the interactive fountain type features is collected by gravity below grade in a collector tank or sump. The water is filtered, disinfected and then pumped to the feature spray discharge heads.
“Modification” – Any act which
changes or alters the original characteristics of the pool as approved. For
example, changes in the recirculation systems, decking, treatment systems,
disinfection system, and pool shape are modifications.
“Marking” or “Markings” – Refers to the placement and installation
of visual marking cues to help patrons identify step, bench and swimout
outlines, slope break location, depth designations, and NO ENTRY and NO DIVING
warnings. When markings are specified by code to be dark the term dark shall
mean a Munsell Color Value from zero to four.
"Perimeter overflow gutter" means a level trough or ledge around the inside perimeter of the pool containing drains to clean the pool water surface.
"Plunge pool" means the receiving body of water located at the terminus of a recreational water slide.
"Pool floor" means the interior pool bottom surface which consists of that area from a horizontal plane up to a maximum of a 45-degree slope.
"Pool wall" means the interior pool side surfaces which consist of that area from a vertical plane to a 45-degree slope.
“Pool
Turnover” – The circulation of the entire pool volume through the filter
system. Pool volume shall be determined from the design water level which is
the normal operating water level; for gutter type pools is the horizontal plane
of the upper lip of the gutter and for skimmer pools is the centerline of the
skimmer opening.
"Precoat pot" means a container with a valved
connection to the suction side of the recirculation pump of a pressure
diatomaceous earth (D.E.) type
filter system used for coating the filter with D. E. powder or NSF/ANSI Standard 50-2007 and
manufacturer approved substitute filter aid.
A "public swimming pool" or "public pool" means a watertight structure of concrete, masonry, or other approved materials which is located either indoors or outdoors, used for bathing or swimming by humans, and filled with a filtered and disinfected water supply, together with buildings, appurtenances, and equipment used in connection therewith. A public swimming pool or public pool shall mean a conventional pool, spa-type pool, wading pool, special purpose pool, or water recreation attraction, to which admission may be gained with or without payment of a fee and includes, but is not limited to, pools operated by or serving camps, churches, cities, counties, day care centers, group home facilities for eight or more clients, health spas, institutions, parks, state agencies, schools, subdivisions, or the cooperative living-type projects of five or more living units, such as apartments, boardinghouses, hotels, mobile home parks, motels, recreational vehicle parks, and townhouses. The term does not include a swimming pool located on the grounds of a private residence.
"Recirculation system" means the system of piping and mechanics designed to remove the water from the pool then filter, disinfect and return it to the pool.
"Slip resistant" means having a textured surface which is not conducive to slipping under contact of bare feet unlike glazed tile or masonry terrazzo and nontextured plastic materials. manufactured surface products shall be designated by the manufacturer as suitable for walking surfaces in wet areas.
"Spa pool" means a pool used in conjunction with high-velocity air or water.
"Special purpose pool" means a public pool used exclusively for a specific, supervised purpose, including springboard or platform diving training, SCUBA diving instruction, and aquatic programs for persons with disabilities, preschool or kindergarten children.
“Swimming
Pool Slide” a slide designed by its manufacturer to discharge over the sidewall
of a swimming pool.
“Swim Spa” – A pool used in conjunction with a
directional flow of water against which one swims.
"Wading pool" means a shallow pool designed to be used by children.
"Water recreation attraction" means a facility
with design and operational features that provide patron recreational activity
and purposefully involves immersion of the body partially or totally in the
water. Water recreation attractions include water slides, lazy river rides, water course rides, water
activity pools, interactive water features
and wave pools and any additional pool within the boundaries of the
attraction.
“Water Activity Pool” – A water
recreation attraction which has water related activities such as rope ladders,
rope swings, cargo nets and other similar activities.
“Water Slides” – A water recreation attraction
ride which is characterized by having trough-like or tubular flumes or chutes.
“
“Water Therapy Facilities” as that term is used in section
514.0115(1), F.S., are pools used exclusively for water therapy to treat a
diagnosed injury, illness, or medical condition, wherein the therapy is
provided under the direct supervision of a Florida licensed physical therapist,
occupational therapist, or athletic trainer; pursuant to a prescription by a
physician or a physician's assistant (PA) licensed pursuant to chapters 458 or
459, F.S., a podiatrist licensed pursuant to chapter 461, F.S., or an advanced
registered nurse practitioner (ARNP) licensed pursuant to chapter 464, F.S.;
and the prescribing physician, PA, podiatrist or ARNP, authorizes a plan of
treatment justifying use of the pool for health care purposes.
"Lazy river ride" means
a water recreation attraction designed to convey bathers around a relatively
flat course using an artificially created current.
"Wade pool" means a water recreation attraction ride which is characterized by having trough-like or tubular flumes or chutes.
“Wave Pool” – A
water recreation attraction that is characterized by wave action.
"Wet deck area" means the 4-foot-wide (1219 mm) unobstructed pool deck area around the
outside of the pool water perimeter, curb, ladders, handrails, diving boards,
diving towers, or pool slides, waterfalls, water features, starting blocks,
planters, or lifeguard chairs.
"Zero depth entry pool" means a pool where the pool floor continues to slope upward to a point where it meets the surface of the water and the pool deck.
424.1.1 Sizing – The bathing load for conventional swimming
pools, wading pools, interactive water features, water
activity pools less than 24” deep, and special purpose pools shall be computed on the basis of
one person per five gallons per minute (gpm) of recirculation flow. The bathing load for wading pools and
interactive water features shall be established by averaging one person per 10
square feet of pool area and one person per 5 gallons per minute of filter
rate. The bathing load
for spa type pools shall be based on one person per each 10 square feet of
surface area. The filtration system for swimming pools shall be capable of meeting all other requirements of these
rules while providing a flowrate of at least one gallon per minute for each
living unit at transient facilities and three-fourths gallon per minute at
non-transient facilities. Recreational vehicle sites, campsites and boat slips
designated for live-aboards shall be considered a transient living unit.
For properties with multiple pools, this requirement includes the
cumulative total GPM of all swimming pools, excluding spas, wading pools and
interactive water features. All other types of projects shall be sized according to the anticipated
bathing load and proposed uses. For the purpose of determining minimum pool
size only, the pool turnover period used cannot be less than three hours.
424.1.2 Swimming pool construction standards.
424.1.2.1 Pool
structure. Pools shall be constructed of concrete or other impervious and
structurally rigid material. All pools shall be watertight, free from
structural cracks and shall have a nontoxic smooth and slip-resistant finish. All materials shall be installed in
accordance with manufacturer’s specifications unless such specifications
violate Chapter 64E-9, F.A.C., rule requirements or the approval criteria of
NSF/ANSI Standard 50-2007 or NSF/ANSI Standard 60-2005.
(a)
Floors
and walls shall be white or pastel in color and shall have the characteristics
of reflecting rather than absorbing light.
Tile used in less than 5 feet (1524 mm) of water must be slip resistant. A minimum 4 inch tile line,
each tile a minimum
size of one inch on all sides shall be installed at the water line, but shall not exceed 12 inches in
height if a dark color is used. Gutter type pools may substitute 2-inch tile, each a minimum size of one inch on
all sides, along the pool
wall edge of the gutter lip.
(b)
One inch square tile may be used if the licensed contractor provides
a signed written certification to the approving department engineer that the
adhesive used on the one inch square tile has a manufacturer's tested shear
strength of at least 250 psi and the manufacturer has specified the adhesive
for use underwater to adhere the type of tile used (vitreous (glass) or
ceramic). Tiles shall not have sharp edges exposed that could cause bather
injury.
424.1.2.2 Dimensions.
424.1.2.2.1 Dimensional standards. Dimensional standards for competition type pools shall be those published by the National Collegiate Athletic Association, 1990; Federation Internationale de Natation Amateur (FINA), 1998-2000 Handbook; 1998-1999 Official Rules of Diving & Code Regulation of United States Diving Inc.; 1998 United States Swimming Rules and Regulations, and National Federation of State High School Associations, 1997-1998, which are incorporated by reference in this code.
424.1.2.2.2 Walls and corners. All
pool walls shall have a clearance of 15 feet (4572 mm) perpendicular to the
wall (as measured
at design water level from gutter lip to gutter lip, or on skimmer pools, from
vertical wall to vertical wall). Offset steps and spa coves, spa pools and wading pools are exempt from this clearance requirement. Where interior steps protrude into the
pool resulting in less than 15 feet of clearance from any wall such protrusion
shall not exceed six feet on any perpendicular line from a tangent to any pool
wall from which the steps emanate. The upper part of pool walls in areas 5 feet deep or less shall be within
5 degrees (4572 mm) vertical for a minimum depth of 2½ feet (762 mm) from which
point the wall may join the floor with a maximum radius equal to the difference
between the pool depth and 2½ feet. The upper part of pool walls in areas over
5 feet deep shall be within 5 degrees vertical for a minimum depth equal to the
pool water depth minus 2½ feet (762 mm) from which point the wall may join the
floor with a maximum radius of 2½ feet (762 mm). Corners shall be a minimum
90-degree angle. The corner intersections of walls which protrude or angle into
the pool water area shall be rounded with a minimum radius of 2 inches (51
mm). This radius shall be continued through the top of the gutter
edge; chamfering is allowed. Pool coping shall not overhang into
the pool more than one and a half inches.
424.1.2.2.3 Pool floor slope and slope transition. The radius of curvature between the floor and walls is excluded from these requirements. multiple floor levels in pools are prohibited.
424.1.2.2.3.1 Floor slope shall be uniform. The floor slope shall be a maximum 1 unit vertical in 10 units horizontal and a minimum of 1 unit vertical in 40 units horizontal in areas 5 feet (1524 mm) deep or less. The floor slope shall be a maximum 1 unit vertical in 3 units horizontal in areas more than 5 feet (1524 mm) deep.
424.1.2.2.3.2 Any
transition in floor slope shall occur at a minimum of 5 feet (1524 mm) of water
depth. A slope transition
must have a 2 to 6 inch wide dark contrasting tile marking across the bottom
and must extend up both sides of the pool at the transition point. The
marking shall be continuous except for recessing grouting. A slope transition must have a safety line
mounted by use of recessed cup anchors, 2 feet (610 mm) before the contrasting
marking, towards the shallow end. The safety line shall have visible floats at
maximum 7-foot (2134 mm) intervals.
424.1.2.2.4 Pool depths. The minimum water depth shall be 3 feet (914 mm) in shallow areas and 4 feet (1219 mm) in deep areas.
424.1.2.3 Markings.
424.1.2.3.1 Depth and markings. Depth
and markings shall meet the following criteria:
1. The minimum water depth shall be 3 feet in
shallow areas and 4 feet in deep areas.
2. Permanent depth
markings followed by the appropriate full or abbreviated words
"FEET", “FT” or "INCHES", “IN” shall be installed in
minimum 4-inch-high (102 mm) numbers and letters on a contrasting background.
Depth markers shall indicate the actual pool depth, within 3 inches (76 mm), at
normal operating water level when measured 3 feet (914 m3) from the pool wall.
Symmetrical pool designs with the deep point at the center may be allowed
provided a dual marking system is used which indicates the depth at the wall
and at the deep point.
3. At a minimum, the markings shall be located on both sides of the pool
at the shallow end, slope break, deep end wall and deep point (if located more
than five feet from the deep end wall). Depth markings shall be legible from inside the pool and also
from the pool deck. The maximum
perimeter distance between depth markings is of 25 feet (7620 mm). Pool size and geometry may necessitate
additional depth marking placements about all sides of the pool to meet this
requirement.
4. When a curb is provided, the depth markings shall be
installed on the inside and outside or top of the pool curb. When a pool curb
is not provided, the depth markings shall be located on the inside vertical
wall at or above the water level and on the edge of the deck within 2 feet of the pool water. When open type
gutter designs are utilized, depth markers shall be located on the back of the
gutter wall.
5. When deck level
perimeter overflow systems are utilized, additional depth marking signs shall
be posted nearby or placed on adjacent fencing or walls and the size shall be
increased so they are recognizable from inside the swimming pool. Alternatively tile depth markers may be placed at the top of the pool wall
just under the water level.
Depth markers placed on the pool deck shall be within 3 feet of the water.
6. Those areas of the pool that
are not part of an approved diving bowl shall have dark contrasting tile 4-inch-high
(102 mm) "NO DIVING" markings installed along the perimeter of the
pool on the top of the pool curb or deck within 2 feet (610 mm)of the
pool water with a maximum perimeter distance of 25 feet (7620 mm) between
markings. A 6-inch tile with a 4-inch (102 mm) or larger red,
international "NO DIVING" symbol may be substituted for the "NO
DIVING" markings.
7. All markings shall be tile,
except that pools constructed of fiberglass, thermoplastic or stainless steel
may substitute other type markings when it can be shown that said markings are
permanent and will not fade over time. This exemption does not extend to concrete
pools that are coated with fiberglass. Tile alternative examples include stone or manufactured
plaques with engraved or sandblasted numbers and characters with permanent
paint. Permanent appliqués may be used for fiberglass, thermoplastic or
stainless steel pools. All markings installed on horizontal surfaces shall have
a slip resistant finish. Markings shall be flush with the surrounding area
where placed and recessed if necessary to provide a smooth finish that will
avoid creation of an injury hazard to bathers. Pools that are not conducive to
tile can employ other equivalent markings as stated above.
424.1.2.3.2 Designs or logos. Any design or logo on the pool floor or walls shall be such that it will not hinder the detection of a human in distress, algae, sediment, or other objects in the pool.
424.1.2.3.3 Lane
markings. Pools that are not intended to be utilized for officially sanctioned
competition may install lap lane markings provided they meet the following
criteria: the markings must be 2 to 6 4
inches (102 mm) wide, they must terminate 5 feet (1524 mm) from the end wall in
a "T" with the "T" bar at least 18 inches (1524 mm) long,
they must be placed at 7-foot (2134 mm) intervals on center and be no closer
than 4 feet (1219 mm) from any side wall, steps or other obstructions. Floating rope lines associated with lap lanes must not obstruct the
entrance or exit from the pool and are prohibited when the pool is open for
general use.
424.1.2.3.4 Targets.
Pools that are not intended
for officially sanctioned competition may have a 2 to 6 inch (102 mm) wide 18-inch by 18-inch (457 mm
by 457 mm) targets (+) installed on the pool wall.
424.1.2.4 Color. Pool floors and walls shall be white or light pastel in color and shall have the characteristic of reflecting rather than absorbing light.
Exception: A dark color may be used if (1) a tile line [minimum 4 inches (102 mm), maximum 12 inches (305 mm)] is installed at the water line or (2) if 2-inch (51 mm) tile is installed along the pool wall edge of the gutter lip for gutter type pools.
424.1.2.5 Access. All pools shall have a means of access every 75 feet (22 860 mm) of pool perimeter with a minimum of two, located so as to serve both ends of the pool. In addition, an access point shall be provided at the deep portion, if the deep portion is not at one end of the pool. When the deep portion of the pool is over 30 feet (9144 mm) wide both sides of this area shall have a means of access. Access shall consist of ladders, stairs, recessed treads or swimouts and may be used in combination. All treads shall have a slip-resistant surface.
424.1.2.5.1 Ladders.
Ladders shall be of the
cross-braced type and shall be constructed of corrosion-resistant materials and
be securely anchored into the pool deck. Clearance between the ladder and pool
wall shall be between 3 to 6 inches (76 mm to 152 mm). Ladders shall extend at
least 28 inches (711 mm) and no more than 40 inches above the pool deck. Ladder bottom braces shall have intact end caps or
bumpers that rest firmly against the pool wall.
The top rung
of the ladder shall be at or below the water level on open gutter pools and not
more than 12 inches below the deck or curb top on all other type pools.
424.1.2.5.2 Recessed treads. Recessed treads shall be installed flush with the wall and shall be a minimum five inches wide, 10 inches (254 mm) long, with a maximum vertical distance of 12 inches (305 mm) between treads.
424.1.2.5.3 Stairs. Stairs shall have a minimum tread width of 10
inches (254 mm) and a maximum width of 48 inches for a minimum tread length of
24 inches (610 mm) and a maximum riser height of 10 inches (254 mm). Treads and
risers between the top and bottom treads shall be uniform to within 1/2 inch in
width and height. The riser heights shall be measured at the marked step
edges and the differences in elevation shall be considered the riser heights. The
front ¾ to 2 inches (19.1 to 51 mm) of the tread and the top 2 inches (51mm) of
the riser shall be tile, dark in color, contrasting with the interior of the
pool. Tile shall be slip resistant.
Bullnose tile that
is slip resistant may be is used when the ¾ inch (19 mm)
segment is placed on the tread or horizontal surface and the 2-inch (51 mm)
segment is placed on the riser or vertical surface. Where the gutter is used as the top step, the tile on the
gutter for the width of the steps shall be slip resistant. Vinyl liner and
fiberglass pools may use other material for the step edge marking,
provided the material is permanent, permanently secured, dark in color,
non-fading, and slip resistant.
424.1.2.5.4 Swimouts.
Swimouts shall extend 18 to
24 inches (610 mm) back from the pool wall, shall be 4 to 5 feet (1219 mm to
1524 mm) wide, shall be a maximum of 12 inches (305 mm) below the deck, unless
stairs are provided in the swimout, and shall be located only in areas of the
pool greater than 5 feet (1524 mm) deep. Pools that do not utilize a continuous
perimeter overflow system must provide a wall return inlet in the swimout for
circulation. A permanent dark contrasting colored band of tile shall be
installed at the intersection of the pool wall and the swimout and must extend
2 inches (51 mm) on the horizontal and vertical surfaces. Tile must be slip
resistant. Bullnose tile may be substituted and installed in
accordance with Section 424.1.2.5.3 above.
424.1.2.5.5 Handrails and grabrails. Handrails
shall be provided for all stairs, shall be anchored in the bottom step and the
deck. Where "figure 4" deck- mounted type handrails are used, they
shall be anchored in the deck and extend laterally to any point vertically
above the bottom step. Grabrails must be
mounted in the pool deck at each side of recessed steps. Handrails and
grabrails shall extend between at least 28 and 40
inches above the step edge and deck.
424.1.2.5.6 Disabled access. Permanent
or portable steps, ramps, handrails, lifts or other devices designed to
accommodate handicapped individuals in swimming pools may be provided. Lifts
mounted into the pool deck shall have a minimum four 4-foot-wide (1219 mm) deck
behind the lift mount.
424.1.2.6 Obstructions.
The pool water area shall be
unobstructed by any type structure unless justified by engineering design as a
part of the recirculation system. Engineering design and material
specifications shall show that such structures will not endanger the pool
patron, can be maintained in a sanitary condition and will not create a problem
for sanitary maintenance of any part of the pool, pool water, or pool
facilities. Structures in accord with the above shall not be located in a
diving bowl area or within 15 feet (4572 mm) of any pool wall.
Exceptions:
1. Stairs, ladders and ramps,
necessary for entrance/exit from the pool are not considered obstructions.
2. Underwater
seat benches may be installed in areas less than five feet (1524 mm) deep.
Bench seats must be 14 to 18 inches (356 to 457 mm) wide and must have a dark
contrasting tile marking on the seat edge extending two inches (51 mm) on the horizontal and vertical
surface. Tile
shall must be slip
resistant. Bullnose tile may be
substituted and installed in accordance with Section 424.1.2.5.3. Vinyl liner, stainless steel, and
fiberglass pools may use other material for the bench edge marking as detailed
in s. 424.1.2.3.1(7) above, provided the material is permanently secured, dark
in color, non-fading, and slip resistant. Benches shall not
protrude into the 15 foot clearance requirement of Section 424.1.2.6.
424.1.2.7 Diving areas.
Diving facilities shall meet
the minimum requirements of the FINA dimensions for diving facilities in
accordance with the 2005-2009 1998-2000 FINA Handbook and include the following:
1. Diving boards or platforms with heights
of less than the established standard shall meet the dimensional requirements
of the next greater height.
2. Diving boards, platforms and ladders
shall have a nonabsorbent, slip-resistant finish and be of sufficient strength
to safely carry the anticipated loads. Diving equipment one meter and greater
shall have guard rails which extend to the edge of the pool wall. All diving
boards over 21 inches (533 mm) from the deck shall be provided with a ladder.
Diving boards or platforms shall not be installed on curved walls where the
wall enters into the defined rectangular diving area specified in this section.
Adjacent platform and diving boards shall be parallel.
3. The location of pool ladders shall be
such that the distance from the ladder to any point on a diving board or
platform centerline is not less than the plummet to side wall dimension (b)
indicated in the FINA standards. Trampoline-type diving facilities are
prohibited.
4. Diving targets may be installed in
accordance with FINA standards.
424.1.3 Pool appurtenances.
424.1.3.1 Decks and walkways.
424.1.3.1.1 Pool wet decks shall be constructed of concrete or other nonabsorbent material having a smooth slip-resistant finish. Wet deck area finishes shall be designed for such use and shall be installed in accordance with the manufacturer's specifications. Wooden decks and walkways are prohibited.
424.1.3.1.2 Pool wet decks shall be uniformly sloped at a minimum of 2 percent to a maximum of 4 percent away from the pool or to deck drains to prevent standing water. Textured deck finishes that provide pitting and crevices of more than three-sixteenths inch (3/16”) deep that accumulate soil are prohibited. If settling or weathering occurs that would cause standing water, the original slopes shall be restored or corrective drains installed. When a curb is provided, the deck shall not be more than 10 inches (254 mm) below the top of the curb.
TABLE 424.1.6.1
PUBLIC SWIMMING POOL – REQUIRED
FIXTURES REQUIRED COUNT
SIZE OF POOL MEN'S RESTROOM WOMEN'S RESTROOM
Urinals WC Lavatory WC Lavatory
0 - 2,500 sq. ft. 1 1 1 1 1
2,501 - 5,000 sq. ft. 2 1 1 5 1
5,001 - 7,500 sq. ft. 2 2 2 6 2
7,501 - 10,000 sq. ft. 3
3 2 3 9 8
3
For SI: 1 square foot = 0.0929 m2.
An additional set of fixtures shall be provided in the men's
restroom for every 7,500 5,000 square feet or major fraction thereof for
pools greater than 10,000 square
feet.
Women's restrooms shall have a ratio of three to two water
closets provided for women as the combined total of water closets and urinals
provided for men. Lavatory
counts shall be equal.
424.1.3.1.3 Pool wet decks shall have a minimum
unobstructed width of four 4 feet (1219 mm) around the perimeter of
the pool, pool curb, ladders, handrails, diving boards, diving towers and
slides.
424.1.3.1.4 Traffic barriers shall be provided as needed so that parked vehicles do not extend over the deck area.
424.1.3.1.5 Walkways shall be provided between the pool and the sanitary facilities, and shall be constructed of concrete or other nonabsorbent material having a smooth slip-resistant finish for the first 15 feet (4572 mm) of the walkway measured from the nearest pool water's edge. A hose bibb with a vacuum breaker shall be provided to allow the deck to be washed down with potable water.
424.1.3.1.6 Ten
percent of the deck along the pool perimeter may be obstructed. Obstructions shall have a wet deck area
behind or through them, with the near edge of the walk within 15 feet (4572 mm)
of the water except approved
slide obstructions shall have the near edge of the walk within 35 feet of the
water. These obstructions must
be protected by a barrier or must be designed to discourage patron access. When
an obstruction exists in multiple areas around the pool the minimum distance
between obstructions shall be 4 feet (1219 mm).
424.1.3.1.7 Food or drink service facilities shall not be located within 12 feet (3658 mm) of the water's edge.
424.1.3.1.8 The vertical clearance above the pool deck shall be at least 7 feet (2137 mm).
424.1.3.1.9
All public pools shall be surrounded by a minimum 48 inch high fence or other approved substantial
barrier. The fence
shall be continuous around the perimeter of the pool area that is not otherwise
blocked or obstructed by adjacent buildings or structures and shall adjoin with
itself or abut to the adjacent members. Access through the barrier or fence from dwelling units such
as homes, apartments, motel rooms, and hotel rooms, other than from doored exits of
adjacent building(s) shall be through self-closing self-latching
lockable gates of 48 inch minimal height from the floor or ground with
the latch located a minimum of 54 inches from the bottom of the gate or at
least 3 inches below the top of the gate on the pool side. If the self-closing self-latching
gate is also self-locking and is operated by a key lock, electronic opener, or
integral combination lock, then the operable parts of such locks or openers
shall be 34 inches minimum and 48 inches maximum above the finished floor or
ground. Gates
shall open outward away from the pool area.
A latched,
lockable gate shall be placed in the fence within ten feet of the closest point
between the pool and the equipment area for service access.
Instead of a fence, permanent
natural or man-made features such as bulkheads, canals, lakes, navigable
waterways, etc., adjacent to a pool may be permitted as a barrier when approved
by the department. When evaluating such barrier features, the
department the applicable governing body may perform onsite inspections,
and review evidence, such as surveys, aerial photographs, water management
agency standards and specifications, and any other similar documentation to
verify at minimum, the following: the barrier feature is not subject to natural
changes, deviations, or alterations and is capable of providing an equivalent
level of protection as that provided by a structure, and the barrier feature
clearly impedes, prohibits or restricts access to the pool.
Screened pool enclosures must be hardened on the bottom three feet.
Fencing consideration Consideration shall be given to the U.S. Consumer
Product Safety Commission (CPSC) Publication. No. 362, March 2005, guidelines available from CPSC.gov; or
sections 424.2.17.1.1 – 424.2.17.1.8. Safety
Covers that comply with ASTM F 1346-91 (Reapproved 2003), titled Safety Covers and Labeling
Requirements for All Covers for Swimming Pools, Spas and Hot Tubs, and
available from ASTM.org,
do not satisfy this requirement.
424.1.4 Electrical systems.
424.1.4.1 Electrical equipment and wiring. Electrical equipment wiring and installation, including the grounding of pool components shall conform with Chapter 27 of the Florida Building Code, Building.
424.1.4.2 Lighting. Artificial lighting shall be provided at all swimming pools which are to be used at night or which do not have adequate natural lighting so that all portions of the pool, including the bottom, may be readily seen without glare.
424.1.4.2.1 Outdoor pool lighting. Overhead Lighting
shall provide a minimum of 3 footcandles (30 lux) of illumination at the pool
water surface and the pool wet deck surface. Underwater lighting shall
be a minimum of ½ watt per square foot of pool water surface area.
424.1.4.2.2 Indoor pool lighting. Overhead Lighting shall provide a minimum of 10 foot candles of illumination at
the pool water surface and the pool wet deck surface. Underwater
lighting shall be a minimum of 8/10 watt per square foot of pool surface area.
424.1.4.2.3 Underwater lighting. Underwater
lighting shall utilize transformers and low-voltage circuits with each
underwater light being grounded. The maximum voltage for each light shall be 15
volts and the maximum incandescent lamp size shall be 300 watts. The location
of the underwater lights shall be such that the underwater illumination is as
uniform as possible and shall not be less than 18 inches (457 mm) below the
normal operating water level determined by the centerline of the skimmer or top lip of the gutter. All underwater lights which depend upon
submersion for safe operation shall have protection from overheating when not
submerged. Underwater lighting requirements can be waived when the overhead
lighting provides at least 15 footcandles (150 lux) of illumination at the pool
water surface and pool wet deck surface. Alternative lighting systems which use 15 volts or less, or use no do not utilize
electricity in the pool or on the pool deck, such as LED, (light emitting diode) or fiber-optic systems, may be utilized if the
applicant demonstrates to reasonable certainty that the system development has
advanced to the point where
the department is convinced that
the pool illumination is equal to the requirements in Sections 424.1.4.2.1 and
424.1.4.2.2 above.
424.1.4.2.4 Overhead wiring. Overhead service wiring shall not pass within an area extending a distance of 10 feet horizontally away from the inside edge of the pool walls, diving structures, observation stands, towers, or platforms. Allowances for overhead conductor clearances to pools that meet the safety standards in the National Electrical Code may used instead. Electrical equipment wiring and installation including the grounding of pool components shall comply with Chapter 27 of the Florida Building Code, Building.
424.1.5 Equipment area or rooms.
424.1.5.1 Eequipment. Equipment
designated by the manufacturer for outdoor use may be located in an equipment
area, all other equipment must be located in an equipment room or
enclosure. Plastic pipe subject to a period of
prolonged sunlight exposure must be coated to protect it from ultraviolet light
degradation. An equipment area
shall be surrounded with a fence at least 4 feet (1219 mm) high on all sides not confined by a building or
equivalent structure. A self-closing
and self-latching gate with a permanent locking device shall be provided if necessary for access. An equipment room shall be protected on at
least three sides and overhead. Any fence or gate installed shall use members spacing that shall not allow passage
of a 4 inch diameter sphere.
The fourth side may be a gate, fence, or open if otherwise protected from
unauthorized entrance. An
equipment enclosure shall be lockable or otherwise protected from unauthorized
access.
424.1.5.2 Indoor equipment. Equipment not designated by the manufacturer for outdoor use shall be located in an equipment room. An equipment room shall be protected on at least three sides and overhead. The fourth side may be a gate, fence or open if otherwise protected from unauthorized entrance.
424.1.5.3 Materials. The
equipment enclosure, area or room floor shall be of concrete or other
nonabsorbent material having a smooth slip-resistant finish and shall have
positive drainage, including a sump pump if necessary. Ancillary equipment, such as a heater, not contained in an equipment
enclosure or room shall necessitate an equipment area as described above.
424.1.5.4 Ventilation. Equipment rooms shall have either
forced draft or cross ventilation. All below-grade equipment rooms shall have a
stairway access with forced draft ventilation or a fully louvered door and powered intake within 6 inches of
the floor louvered vent on at
least one other side. Where stairway access is not
necessary to carry heavy items into the below grade room or vault, a “ship’s
ladder” may be used if specified by the design engineer who must consider anticipated workload including
equipment removal; and the ladder slope, tread height and width; and
construction material of the ladder.
424.1.5.5 Access. The opening to an equipment room or area shall be a minimum 3 feet by 6 feet (914 mm by 1829 mm) and shall provide easy access to the equipment.
424.1.5.6 Size. The size of the equipment enclosure,
room or area shall provide working space to perform routine operations.
Clearance shall be provided for all equipment as prescribed by the manufacturer
to allow normal maintenance operation and removal without disturbing other
piping or equipment. In rooms with fixed
ceilings, the minimum height shall be 7 feet (2137 mm).
424.1.5.7 Lighting. Equipment rooms or areas shall be lighted to provide 30 footcandles (300 lux) of illumination at floor level.
424.1.5.8 Storage.
Equipment enclosures, rooms
or areas shall not be used for storage of chemicals emitting corrosive fumes or
for storage of other items to the extent that entrance to the room for
inspection or operation of the equipment is impaired.
424.1.5.9 Hose bibbs. A hose bibb with vacuum breaker shall be located in the equipment room or area.
424.1.6 Plumbing systems.
424.1.6.1 Sanitary facilities. Swimming pools with a bathing load of 20 persons or less may
utilize a unisex restroom. Pools with bathing loads of 40 persons or less may
utilize two unisex restrooms or meet the requirement on the chart below. Unisex
restrooms shall meet all the requirements for materials, drainage and signage
as indicated in sections 424.1.6.1.1 through 424.1.6.1.4. Each shall include a water closet, a diaper
change table, a urinal, and a lavatory. Pools with a bathing load larger than
40 persons shall provide separate Separate sanitary facilities
shall be provided and labeled for each
sex. And The entry doors of all restrooms shall
be located within a 200-foot (60 960 mm) walking distance of the nearest
water’s edge of each pool served by the facilities.
Exception: Where
a swimming pool serves only a designated group of residential dwelling units
and not the general public, poolside sanitary facilities are not required if
all living units are within a 200-foot (60 960 mm) horizontal
radius of the nearest water’s edge, are not over three stories in height unless serviced by an elevator, and are each equipped with private sanitary
facilities.
424.1.6.1.1
Required fixtures. Fixtures shall be provided as indicated on Table
424.1.6.1. The fixture count on this chart is
deemed to be adequate for the pool and pool deck area that is up to three times
the area of the pool surface provided.
When multiple fixture sets are required and separate
facilities are provided for each sex the fixtures used in ancillary family
style restrooms can be used to meet the requirements of Section 424.1.6.1.1
One diaper Diaper changing tables shall be provided at each restroom. Diaper changing tables are not required at
restrooms where all pools served are restricted to adult use only. Swim diapers
are recommended for use by children that are not toilet trained.
Persons that are ill with diarrhea can not enter the pool. facilities
that cater to families with small children.
424.1.6.1.2 Outside access. Outside access to facilities
shall be provided for bathers at outdoor pools. Where the restrooms are located within an adjacent building
and the restroom doors
do not open to the outside, the restroom doors shall be within 50 feet
of the buildings exterior door. If they the restrooms are not visible from any portion of
the pool deck, signs shall be posted showing directions to the facilities.
Directions shall be legible from any portion of the pool deck; letters shall be
a minimum of 1 inch (25 mm) high.
424.1.6.1.3 Sanitary facility floors. Floors of sanitary
facilities shall be constructed of concrete or other nonabsorbent materials,
shall have a smooth, slip-resistant finish, and shall slope to floor drains.
Carpets, duckboards and footbaths are prohibited. The intersection between the
floor and walls shall be covered where either floor or wall is not made of waterproof materials such
as tile or vinyl.
424.1.6.1.4 Hose bibb. A hose bibb with vacuum breaker shall
be provided near in or within 25 feet of each restroom to allow for ease of cleaning.
424.1.6.2 Rinse shower. A minimum of one rinse shower shall be provided on the pool deck of all outdoor pools within 20 feet (60 960 mm) of the nearest pool water's edge.
424.1.6.3 Cross-connection prevention. An atmospheric break or approved back flow prevention device shall be provided in each pool water supply line that is connected to a public water supply. Vacuum breakers shall be installed on all hose bibbs.
424.1.6.4 Plastic pipes. Plastic pipe subject to a period of prolonged sunlight exposure shall be coated to protect it from ultraviolet light degradation.
424.1.6.5 Recirculation and treatment systems.
424.1.6.5.1 Equipment testing. Recirculation and treatment
equipment such as filters, recessed automatic surface skimmers, ionizers, ozone
generators, disinfection feeders and chlorine generators shall be tested and
approved using the ANSI/NSF International
Standard 50-2007, Circulation System
Components and Related materials for Swimming Pool, Spas/Hot Tubs, dated April, 2007 October 28,
1996, which is incorporated by reference.
424.1.6.5.2 Volume. The recirculation system shall be designed to provide a minimum of four turnovers of the pool volume per day. Pools that are less than 1,000 square feet (93 m3) at health clubs shall be required to provide eight turnovers per day.
424.1.6.5.3 System design. The design pattern of recirculation flow shall be 100 percent through the main drain piping and 100 percent through the perimeter overflow system or 60 percent through the skimmer system.
424.1.6.5.3.1 Perimeter overflow gutters. The lip of the
gutter shall be uniformly level with a maximum tolerance of 1/4 inch (6 mm)
between the high and low areas. The bottom of the gutter shall be level or
slope to the drains. The spacing between drains shall not exceed 10 feet (3048
mm) for 2-inch (51 mm) drains or 15 feet (4572 mm) for 21/2-inch (64 mm)
drains, unless hydraulically justified by the design engineer. Gutters may be eliminated along pool edges for no more than fifteen
feet and this shall not exceed 10% of the perimeter (at least 90% of the
perimeter shall be guttered). In areas where gutters are eliminated, handholds
shall be provided within nine inches of the water surface. Handhold design
shall be approved by the department prior to construction.
424.1.6.5.3.1.1 Either recessed type or open type gutters shall be used. Special designs can be approved provided they are within limits of sound engineering practice. Recessed type gutters shall be at least 4 inches (102 mm) deep and 4 inches (102 mm) wide. No part of the recessed gutter shall be visible from a position directly above the gutter sighting vertically down the edge of the deck or curb. Open-type gutters shall be at least 6 inches (150 mm) deep and 12 inches (305 mm) wide. The gutter shall slope 2 inches (51 mm), +/-1/4 inch (+/-6 mm), from the lip to the drains. The gutter drains shall be located at the deepest part of the gutter.
424.1.6.5.3.1.2 All gutter systems shall discharge into a collector tank.
424.1.6.5.3.1.3 The gutter lip shall be tiled with a minimum of 2-inch (51 mm) tile on the pool wall, each a minimum size of one inch on all sides. The back vertical wall of the gutter shall be tiled with glazed tile.
Exception: Stainless steel gutter systems when it can be shown that the surfaces at the waterline and back of the gutter are easily cleanable.
424.1.6.5.3.2 Recessed automatic surface skimmers. Recessed automatic surface skimmers may be utilized when the pool water surface area is 1,000 square feet (93 m3) or less excluding offset stairs and swimouts and the width of the pool is not over 20 feet (6096 mm).
424.1.6.5.3.2.1 Volume. The recessed automatic surface skimmer piping system shall be designed to carry 60 percent of the pool total design flow rate with each skimmer carrying a minimum 30 gpm (2 L/s). One skimmer for every 400 square feet (37 m2) or fraction thereof of pool water surface area shall be provided.
424.1.6.5.3.2.2 Location. Prevailing wind direction and the pool outline shall be considered by the designer in the selection of skimmer locations. The location of skimmers shall be such that the interference of adjacent inlets and skimmers is minimized. Recessed automatic surface skimmers shall be installed so that there is no protrusion into the pool water area. The deck or curb shall provide for a handhold around the entire pool perimeter and shall not be located more than 9 inches (229 mm) above the mid point of the opening of the skimmer.
424.1.6.5.3.2.3 Equalizers. Recessed automatic surface skimmers
shall be installed with an equalizer valve and an equalizer line when the
skimmer piping system is connected directly to pump suction. If installed, the The equalizer valve shall be a spring loaded
vertical check valve which will not allow direct suction on the equalizer line. Float valves are prohibited. The equalizer line inlet shall be installed at
least 1 foot (305 mm) below the normal pool water level and the equalizer line
inlet shall be protected by an
ASME/ANSI A112.19.8-2007 compliant cover/grate. The equalizer line shall be sized to handle the expected
flow with a 2-inch (51 mm) minimum line size.
424.1.6.5.3.2.4 Wall-inlet fitting. A wall-inlet fitting shall be provided directly across from each skimmer.
424.1.6.5.3.2.5 Waterline tile. A minimum 6- inch (152 mm) water line tile shall be provided on all pools with automatic skimmer systems, each a minimum size of one inch on all sides. Glazed tile that is smooth and easily cleanable shall be utilized.
424.1.6.5.4 Pumps. If the pump or suction piping is located above the water level of the pool, the pump shall be self-priming. Pumps that take suction prior to filtration shall be equipped with a hair and lint strainer. The recirculation pump shall be selected to provide the required recirculation flow against a minimum total dynamic head of 60 feet (18 288 mm) unless hydraulically justified by the design engineer. Vacuum D.E. filter system pumps shall provide at least 50 feet (15 240 mm) of total dynamic head. Should the total dynamic head required not be appropriate for a given project, the design engineer shall provide an alternative.
424.1.6.5.5 Filters. Filters sized to handle the required recirculation flow shall be provided.
424.1.6.5.5.1 Filter capacities. The maximum filtration rate in gallons per minute per square foot of filter area shall be: 15 (20 if so approved using the procedure stated in Section 424.1.6.5.1 for high rate sand filters, 3 for rapid sand filters, 0.075 for pleated cartridge filters and 2 for Diatomaceous Earth (D.E) type filters).
424.1.6.5.5.2 Filter appurtenances.
424.1.6.5.5.2.1 Pressure filter systems. Pressure filter systems shall be equipped with an air relief valve, influent and effluent pressure gauges with minimum face size of 2 inches (51 mm) reading 0-60 psi (0-414 kPa), and a sight glass when a backwash line is required.
424.1.6.5.5.2.2 Vacuum filter systems. Vacuum filter systems shall be equipped with a vacuum gauge which has a 2-inch (51 mm) face and reads from 0-30 inches of mercury.
424.1.6.5.5.2.3 D.E. systems. A precoat pot or collector tank shall be provided for D.E. type systems.
424.1.6.5.5.3 Filter tanks and elements. The filter area
shall be determined on the basis of effective filtering surfaces with no
allowance given for areas of impaired filtration, such as broad supports,
folds, or portions which may bridge. D.E. filter Filter elements shall have a minimum 1-inch (25
mm) clear spacing between elements up to a 4 square foot (.4 m2) effective
area. The spacing between filter elements shall increase 1/8 inch (3 mm) for
each additional square foot of filter area or fraction thereof above an
effective filter area of 4 square feet (.4 m2). All cartridges used in public
pool filters shall be permanently marked with the manufacturer's name, pore
size and area in square feet of filter material. All cartridges with end caps
shall have the permanent markings on one end cap. Vacuum filter tanks shall
have covered intersections between the
wall and the floor and the tank floor shall slope to the filter tank drain. The
D.E. filter tank and elements shall be
installed such that the recirculation flow draw down does not expose the
elements to the atmosphere whenever only the main drain valve is open or only
the surface overflow gutter system valve is open.
424.1.6.5.6 Piping. All plastic pipe used in the recirculation system shall be imprinted with the manufacturer's name and the NSF-pw logo for potable water applications. Size, schedule and type of pipe shall be included on the drawings. Plastic pipe subject to a period of prolonged sunlight exposure shall be coated to protect it from ultraviolet light degradation.
424.1.6.5.7 Valves. Return lines, main drain lines, and surface overflow system lines, shall each have proportioning valves.
424.1.6.5.8 Flow velocity. Pressure piping shall not exceed 8 feet per second (2438 mm/s), except that precoat lines with higher velocities may be used when necessary for agitation purposes. The flow velocity in suction piping shall not exceed 6 feet per second (1829 mm/s) except that flow velocities up to 10 feet per second (3048 mm/s) in filter assembly headers will be acceptable. main drain systems and surface overflow systems which discharge to collector tanks shall be sized with a maximum flow velocity of 3 feet per second (914 mm/s). The filter and vacuuming system shall have the necessary valves and piping to allow filtering to pool, vacuuming to waste, vacuuming to filter, complete drainage of the filter tank, backwashing for sand and pressure D.E. type filters and precoat recirculation for D.E. type filters.
424.1.6.5.9
Inlets. All inlets shall be adjustable with wall type inlets being
directionally adjustable and floor type inlets having a means of flow
adjustment. Floor inlets shall
be designed and installed such that they do not protrude above the pool floor
and all inlets shall be designed and installed so as not to constitute sharp
edges or protrusions hazardous to pool bathers. Floor inlets for vinyl liner
and fiberglass pools, shall be smooth with no sharp edges, and shall not extend
more than 3/8 inches above the pool floor. Wall inlets shall be installed a
minimum of 12 inches below the normal operating water level unless precluded by
the pool depth or intended for a specific acceptable purpose.
424.1.6.5.9.1 Pools 30 feet (9144 mm) in width or less, with wall inlets only shall have enough inlets such that the inlet spacing does not exceed 20 feet (6096 mm) based on the pool water perimeter.
424.1.6.5.9.2 Pools 30 feet (9144 mm) in width or less with floor inlets only shall have a number of inlets provided such that the spacing between adjacent inlets does not exceed 20 feet (6096 mm) and the spacing between inlets and adjacent walls does not exceed 10 feet (3048 mm).
424.1.6.5.9.3 A combination of wall and floor inlets may be used in pools 30 feet (9144 mm) in width or less only if requirements of Section 424.1.6.5.9.1 or Section 424.1.6.5.9.2 are fully met.
424.1.6.5.9.4 Pools greater than 30 feet (9144 mm) in width shall have either floor inlets only, or a combination of floor inlets and wall inlets. Pools with floor inlets only shall have a number of floor inlets provided such that the spacing between adjacent inlets does not exceed 20 feet (6096 mm) and the spacing between inlets and an adjacent wall does not exceed 10 feet (3048 mm).
424.1.6.5.9.5 Pools greater than 30 feet (9144 mm) in width with may have a combination of wall and floor inlets shall have provided the number of wall inlets is such that the maximum spacing between the wall inlets is 20 feet (6096 mm) and floor
inlets are provided for the pool water area beyond a 15 feet (4572 mm)
perpendicular distance from all walls. The number of floor inlets shall be such
that the spacing between adjacent inlets does not exceed 20 feet (6096 mm) and
the distance from a floor inlet and an adjacent wall does not exceed 25 feet
(7620 mm). Floor inlets shall be designed and installed such that they do not
protrude more than 5/8 inch (16 mm) above the pool floor and all inlets shall
be designed and installed so as not to constitute sharp edges or protrusions
hazardous to pool bathers.
424.1.6.5.9.6 The flow rate through each inlet shall not exceed 15 gpm (1 L/s).
424.1.6.5.10
424.1.6.5.10.1 The depth at the outlet shall not deviate more than 3 inches (76 mm) from the side wall.
424.1.6.5.10.2 Outlets shall be covered by a secured grating
which requires the use of a tool to remove and whose open area is such that the
maximum velocity of water passing through the openings does not exceed 11/2
feet per second (457 mm/s) at 100 percent of the design recirculation flow. Main drain
covers/grates shall comply with the requirements of ASME/ANSI A112.19.8-2007
and the water velocity of this section.
424.1.6.5.10.3 Multiple outlets, equally spaced from the pool side walls and from each other, shall be installed in pools where the deep portion of the pool is greater than 30 feet (9144 mm) in width.
424.1.6.5.10.4 If the area is subject to high ground water, the pool shall be designed to withstand hydraulic uplift or shall be provided with hydrostatic relief devices.
424.1.6.5.10.5 The main drain outlet shall be connected to a collector tank. The capacity of the collector tank shall be at least 1 minute of the recirculated flow unless justified by the design engineer. Vacuum filter tanks are considered collector tanks.
424.1.6.5.11 Water makeup control. An automatic and manual water makeup control shall be provided to maintain the water level at the lip of the overflow gutter or at the mouth of the recessed automatic surface skimmers and shall discharge through an air gap into a fill pipe or collector tank. Over the rim fill spouts are prohibited.
424.1.6.5.12 Cleaning system. A portable or plumbed in vacuum cleaning system shall be provided. All vacuum pumps shall be equipped with hair and lint strainers. When the system is plumbed in, the vacuum fittings shall be located to allow cleaning the pool with a 50-foot (15 240 mm) maximum length of hose. Vacuum fittings shall be mounted approximately 12 inches (305 mm) below the water level, flush with the pool walls, and shall be provided with a spring loaded safety cover or flush plug cover which shall be in place at all times when the pool is not being vacuumed. Bag-type cleaners, which operate as ejectors on potable water supply pressure, shall be protected by a vacuum breaker. Cleaning devices shall not be used while the pool is open to bathers.
424.1.6.5.13 Rate of flow indicators. A rate of flow indicator, reading in gpm, shall be installed on the return line. The rate of flow indicator shall be properly sized for the design flow rate and shall be capable of measuring from one-half to at least one-and-one-half times the design flow rate. The clearances upstream and downstream from the rate of flow indicator shall comply with manufacturer's installation specifications.
424.1.6.5.14 Heaters. Pool heaters shall comply with nationally recognized standards acceptable to the department and to the design engineer. Pools equipped with heaters shall have a fixed thermometer mounted in the pool recirculation line downstream from the heater outlet. Thermometers mounted on heater outlets do not meet this requirement. A sketch of any proposed heater installation including valves, thermometer, pipe sizes, and material specifications shall be included in the application for permit prior to installation. Piping and influent, effluent and bypass valves which allow isolation or removal of the heater from the system shall be provided. materials used in solar and other heaters shall be nontoxic and acceptable for use with potable water. Heaters shall not prevent the attainment of the required turnover rate.
424.1.6.5.15 Pool waste water disposal. Pool waste water shall be discharged through an air gap; disposal shall be to sanitary sewers, storm sewers, drainfields, or by other means, in accordance with local requirements including obtaining all necessary permits. Disposal of water from pools using D.E. powder shall be accomplished through separation tanks which are equipped with air bleed valves, bottom drain lines, and isolation valves, or through a settling tank with final disposal being acceptable to local authorities. D.E. separator tanks shall have a capacity as rated by the manufacturer, equal to the square footage of the filter system. All lines shall be sized to handle the expected flow. There shall not be a direct physical connection between any drain from a pool or recirculation system and a sewer line.
424.1.6.5.16 Addition of chemicals. Disinfection and pH adjustment shall be added to the pool recirculation flow using automatic feeders meeting the requirement of ANSI/NSF 50 -2007. All chemicals shall be fed into the return line after the pump, heater and filters unless the feeder was designed by the manufacturer and approved by the NSF to feed to the collector tank or to the suction side of the pump.
424.1.6.5.16.1 Gas chlorination. When gas chlorination is
utilized, the chlorinator shall be capable of continuously feeding a chlorine
dosage of 6 4
mg/L to the recirculated flow of the filtration system. The application point
for chlorine shall be located in the return line downstream of the filter,
recirculation pump, heater, and flow meter, and as far as possible from the
pool.
424.1.6.5.16.1.1 Gas chlorinators shall be located in above-grade rooms and in areas which are inaccessible to unauthorized persons.
424.1.6.5.16.1.1.1 Chlorine rooms shall have: continuous forced draft ventilation capable of a minimum of one air change per minute with an exhaust at floor level to the outside, a minimum of 30 footcandles (300 lux) of illumination with the switch located outside and the door shall open out and shall not be located adjacent to the filter room entrance or the pool deck. A shatterproof gas-tight inspection window shall be provided.
424.1.6.5.16.1.1.2 Chlorine areas shall have a roof and shall be enclosed by a chain-link type fence at least 6 feet (1829 mm) high to allow ventilation and prevent vandalism.
424.1.6.5.16.1.2 When booster pumps are used with the chlorinator, the pump shall use recirculated pool water supplied via the recirculation filtration system. The booster pump shall be electrically interlocked with the recirculation pump to prevent the feeding of chlorine when the recirculation pump is not operating.
424.1.6.5.16.1.3 A means of weighing chlorine containers shall be provided. When 150-pound (68 kg) cylinders are used, platform type scales shall be provided and shall be capable of weighing a minimum of two full cylinders at one time. The elevation of the scale platform shall be within 2 inches (51 mm) of the adjacent floor level, and the facilities shall be constructed to allow easy placement of full cylinders on the scales.
424.1.6.5.16.2 Hypohalogenation and electrolytic chlorine generators. The hypohalogenation type feeder and electrolytic chlorine generators shall be adjustable from 0 to full range. A rate of flow indicator is required on erosion type feeders. The feeders shall be capable of continuously feeding a dosage of 6 mg/L to the minimum required turnover flow rate of the filtration systems. Solution feeders shall be capable of feeding the above dosage using a 10-percent sodium hypochlorite solution, or 5-percent calcium hypochlorite solution, whichever disinfectant is to be utilized at this facility. To prevent the disinfectant from siphoning or feeding directly into the pool or pool piping under any type failure of the recirculation equipment, an electrical interlock with the recirculation pump shall be incorporated into the system for electrically operated feeders. The minimum size of the solution reservoirs shall be at least 50 percent of the maximum daily capacity of the feeder. The solution reservoirs shall be marked to indicate contents.
424.1.6.5.16.3 Feeders for pH adjustment. Feeders for pH adjustment shall be provided on all pools, except spa pools of less than 100 square feet (9 m2) of pool water surface area and pools utilizing erosion type chlorinators feeding chlorinated isocyanurates. pH adjustment feeders shall be positive displacement type, shall be adjustable from 0 to full range, and shall have an electrical interlock with the circulation pump to prevent discharge when the recirculation pump is not operating. When soda ash is used for pH adjustment, the maximum concentration of soda ash solution to be fed shall not exceed 1/2-pound (.2 kg) soda ash per gallon of water. Feeders for soda ash shall be capable of feeding a minimum of 3 gallons (11 L) of the above soda ash solution per pound of gas chlorination capacity. The minimum size of the solution reservoirs shall not be less than 50 percent of the maximum daily capacity of the feeder. The solution reservoirs shall be marked to indicate the type of contents.
424.1.6.5.16.4 Ozone generating equipment. Ozone generating equipment may be used for supplemental water treatment on public swimming pools subject to the conditions of this section.
424.1.6.5.16.4.1 Ozone generating equipment electrical components and wiring shall comply with the requirements of the Chapter 27 of the Florida Building Code, Building and the manufacturer shall provide a certificate of conformance. The process equipment shall be provided with an effective means to alert the user when a component of this equipment is not operating.
424.1.6.5.16.4.2 Ozone generating equipment shall meet the NSF/ANS Standard 50-2007.
424.1.6.5.16.4.3 The concentration of ozone in the return line to the pool shall not exceed 0.1 mg/L.
424.1.6.5.16.4.4 The injection point for ozone generating equipment shall be located in the pool return line after the filtration and heating equipment, prior to the halogen injection point, and as far as possible from the nearest pool return inlet with a minimum distance of 4 feet (1219 mm). Injection methods shall include a mixer, contact chamber, or other means of efficiently mixing the ozone with the recirculated water. The injection and mixing equipment shall not prevent the attainment of the required turnover rate of the recirculation system. Ozone generating equipment shall be equipped with a check valve between the generator and the injection point. Ozone generating equipment shall be equipped with an air flow m and a means to control the flow.
424.1.6.5.16.4.5 Ventilation requirements. Ozone generating equipment shall be installed in equipment rooms with either forced draft or cross draft ventilation. Below-grade equipment rooms with ozone generators shall have forced draft ventilation and all equipment rooms with forced draft ventilation shall have the fan control switch located outside the equipment room door. The exhaust fan intake for forced draft ventilation and at least one vent grille for cross draft ventilation shall be located at floor level.
424.1.6.5.16.4.6 A self-contained breathing apparatus designed and rated by its manufacturer for use in ozone contaminated air shall be provided when ozone generator installations are capable of exceeding the maximum pool water ozone contact concentration of 0.1 milligram per liter. The self-contained breathing apparatus shall be available at all times and shall be used at times when the maintenance or service personnel have determined that the equipment room ozone concentration exceeds 10 mg/L. Ozone generator installations which require the self-contained breathing apparatus shall also be provided with Draeger-type detector tube equipment which is capable of detecting ozone levels of 10 mg/L and greater.
Exception: In lieu of the self-contained breathing apparatus an ozone detector capable of detecting 1 mg/L may be used. Said detector shall be capable of stopping the production of ozone, venting the room and sounding an alarm once ozone is detected.
424.1.6.5.16.5 Ionization units may be used as supplemental water treatment on public pools subject to the condition of this section.
424.1.6.5.16.5.1 Ionization equipment and electrical components and wiring shall comply with the requirements of Chapter 27 of the Florida Building Code, Building and the manufacturer shall provide a certification of conformance.
424.1.6.5.16.5.2 Ionization equipment shall meet the ANS Standard 50-2007. Circulation System Components and Related materials for Swimming Pools, Spas/Hot Tubs, or equivalent, shall meet UL standards and shall be electrically interlocked with recirculation pump.
424.1.6.5.16.6 Ultraviolet (UV) light disinfectant equipment may be used as
supplemental water treatment on public pools (and additional treatment on IWFs)
subject to the conditions of this paragraph and manufacturer’s specifications.
UV is encouraged to be used to eliminate or reduce chlorine resistant
pathogens, especially the protozoan Cryptosporidium.
1. UV equipment and electrical
components and wiring shall comply with the requirements of the National
Electrical Code and the manufacturer shall provide a certification of
conformance to the department.
2. UV equipment shall meet UL
standards and shall be electrically interlocked with recirculation pump(s) on
all pools and with feature pump(s) on an IWF such that when the UV equipment
fails to produce the required dosage as measured by an automated sensor, the
feature pump(s) are disabled so the water features do not operate.
3. UV equipment shall be
validated by a capable party that it delivers the required and predicted UV
dose at the validated flow, lamp power and water UV transmittance conditions,
and has complied with all professional practices summarized in the USEPA
Ultraviolet Disinfectant Guidance Manual dated November, 2006, which is
publication number EPA 815-R-06-007 available from the department at
ttp://www.floridashealth.org/Environment/water/swim/index.html or at
http://www.epa.gov/safewater/disinfection/lt2/pdfs/guide_lt2_uvguidance.pdf.
4. UV equipment shall
constantly produce a validated dosage of at least 40 mJ/cm2 (milliJoules per
square centimeter) at the end of lamp life.
5.
The UV equipment shall not be located in a side stream flow and shall be
located to treat all water returning to the pool or water features.
424.1.7 Wading pools.
424.1.7.1 General. Wading pools shall meet the requirements of Sections 424.1.1 through 424.1.6.5, unless otherwise indicated. Wading pools and associated piping shall not be physically connected to any other swimming pools and have no minimum width dimensions requirements.
424.1.7.2 Depths. Wading pools shall have a maximum of 2
feet (610 mm). The depth at the perimeter of the pool shall be uniform and
shall not exceed 12 inches (305 mm). However, where department-approved
zero depth entry designs are used, this uniform depth requirement must be met
only on the remainder of the pool outside the zero depth entry portion. Where recessed automatic
surface skimmers are used, the The pool floor shall not be more than 12 inches (305 mm) below the
deck unless steps and handrails are provided. Depth and "NO DIVING"
markers are not required on wading pools.
424.1.7.3 Recirculation. Wading pools shall have a minimum of one turnover every hour. Lines from main drains shall discharge into a collector tank.
424.1.7.3.1
Skimmer equalizer lines when required shall be plumbed into the main drain installed in the pool floor with a
grate covering.
installed in the pool floor with a grate covering.
424.1.7.3.2 The grate cover shall be sized so as not to allow the flow to exceed 11/2 feet per second (457 mm/s) when the equalizer line is operating.
424.1.7.4 Inlets. Wading pools with 20 feet (6096 mm) or less of perimeter shall have a minimum of two equally spaced adjustable inlets.
424.1.7.5 Emergency drainage. All wading pools shall have drainage to waste without a cross connection through a quick opening valve to facilitate emptying the wading pool should accidental bowel or other discharge occur.
424.1.7.6 Vacuuming. Wading pools with 200 square feet (19 mm) or more of pool water surface area shall have provisions for vacuuming.
424.1.7.7 Wading pool decks. When adjacent to swimming pools,
wading pools shall be separated from the swimming pool by barrier or a fence of a minimum of 48 inches in height with self-latching and
self-closing gates. When adjacent to areas less
than one foot deep of zero depth entry pools, the fence or effective
barrier is required if the water edges are less than 40 feet apart.
or other similar type barrier.
Wading pools shall have a minimum 10-foot (3048 mm) wide deck around at least
50 percent of their perimeter with the remainder of the perimeter deck being at
least 4 feet (1219 mm) wide. There shall be at least 10 feet (3048 mm) between
adjacent swimming pools and wading pools.
424.1.7.8 Lighting. Wading pools are exempt from underwater lighting requirements but shall have overhead lighting installed for night use.
424.1.8 Spa pools.
424.1.8.1 General. Spa pools shall meet the requirements of Sections 424.1.1 through 424.1.6.5, unless specifically indicated otherwise.
424.1.8.2 Color, pattern, finish. The color, pattern or finish of the pool interior shall not obscure the existence or presence of objects or surfaces within the pool.
424.1.8.3 Water depths. Spa type pools shall have a minimum water depth of 21/2 feet (762 mm) and a maximum water depth of 4 feet (1219 mm), except that swim spa pools may have a maximum water depth of 5 feet (1524 mm). Depth markers and "NO DIVING" markers are not required on spa-type pools with 200 square feet (19 m2) or less of water surface area.
424.1.8.4 Steps and handrails. Steps or ladders shall be
provided and shall be located to provide adequate entrance to and exit from the
pool. The number of sets of steps or ladders required shall be on the basis of
one for each 75 feet (22 860 mm), or major fraction thereof, of pool perimeter.
Step sets for spa type pools with more than 200 square feet of pool water
surface area shall comply with Section 424.1.2.5. Step sets for spa-type pools
with 200 square feet (19 m2) or less of pool water surface area shall comply
with the following: Step treads shall have a minimum width of 10 inches (254
mm) for a minimum continuous tread length of 12 inches (305 mm). Step riser
heights shall not exceed 12 inches (305 mm) except
when the bottom step is used for a bench or seat, the bottom riser may be a
maximum of 14 inches (356 mm). Intermediate treads and risers
between the top and bottom treads and risers shall be uniform in width and
height, respectively. Contrasting markings on the leading edges of the
submerged benches and the intersections of the treads and risers are required
to be installed in accordance with Section 424.1.2.5.
424.1.8.4.1 Handrails shall be provided for all sets of steps and shall be anchored in the bottom step and in the deck. Handrails shall be located to provide maximum access to the steps and handrails shall extend 28 inches (711 mm) above the pool deck.
424.1.8.4.2 Where "figure 4" handrails are used, they shall be anchored in the deck and shall extend laterally to any point vertically above the bottom step. Handrails shall be located to provide maximum access to the steps and handrails shall extend 28 inches (711 mm) above the pool deck.
424.1.8.5
Decks. Decks shall have a minimum 4- foot-wide (1219 mm) unobstructed width
around the entire pool perimeter except that pools of less than 120 square feet
(11 m2) of pool water surface area shall have a minimum 4-foot-wide (1219
mm)unobstructed continuous deck around a minimum of 50 percent of the pool
perimeter. Decks less than 4 feet (1219 mm) wide shall have barriers to prevent
their use. Decks shall not be more than 10 inches (254 mm) below the top of the
pool. For pools of 120 square feet or greater, ten percent of the deck
along the pool perimeter may be obstructed.
424.1.8.6 Therapy or jet systems.
424.1.8.6.1 The return lines of spa-type therapy or jet systems shall be independent of the recirculation-filtration and heating systems.
424.1.8.6.2 Therapy or jet pumps shall take suction from the collector tank. Collector tank sizing shall take this additional gallonage into consideration.
424.1.8.7 Filtration system inlets. Spa-type pools with less than 20 feet (6096 mm) of perimeter shall have a minimum of two equally spaced adjustable inlets.
424.1.8.8 Filtration recirculation. Spa-type pools shall have a minimum of one turnover every 30 minutes. The piping, fittings, and hydraulic requirements shall be in accordance with Section 424.1.6.5. All recirculation lines to and from the pool shall be individually valved with proportional flow-type valves in order to control the recirculation flow.
424.1.8.9 Vacuuming. Spa-type pools of over 200 square feet (19 m2) of pool water surface area shall have provisions for vacuuming.
424.1.8.10 Combination spas/pools. When spa pools are part of a conventional swimming pool, the spa pool area shall be offset from the main pool area with the same water depth as the main pool area. The spa pool shall meet all the spa pool requirements of this chapter, and the deck area at the spa shall be protected by connected 30-inch-high (762 mm) stanchions. The deck perimeter at the offset spa area shall not exceed 15 percent of the entire swimming pool perimeter. All benches shall have contrasting markings on the leading edges of the intersection of the bench seats. If tile is used, it shall be slip resistant.
424.1.8.11 Portable and wooden spa pools. Portable and wooden-type spa pools are prohibited.
424.1.9 Water recreation attractions and specialized pools.
424.1.9.1 General. Water recreation attraction projects
shall be designed and constructed within the limits of sound engineering
practice. In addition to the requirements of this section, compliance is
required with Sections 424.1.1 through 424.1.6.5 of this chapter depending upon
the pool design and function. Additionally, all pools listed in this section
shall have a 2 3-hour turnover rate unless otherwise noted.
424.1.9.2 Water slides.
424.1.9.2.1 Water slide plunge pool. Plunge pools shall be constructed of concrete or other structurally rigid impervious materials with a nontoxic, smooth and slip resistant finish. The plunge pool design shall meet the criteria of Sections 424.1.9.2.1.1 through 424.1.9.2.1.7.
424.1.9.2.1.1 Plunge pool water depth. The minimum plunge pool operating water depth at the slide flume terminus shall be 3 feet (914 mm). This depth shall be maintained for a minimum distance of 10 feet (3048 mm) in front of the slide terminus from which point the plunge pool floor may have a constant upward slope to allow a minimum water depth of 2 feet (51 mm) at the base of the steps. The floor slope shall not exceed 1 in 10. The plunge pool water depth shall be commensurate with safety and the ease of exit from the plunge pool.
424.1.9.2.1.2 Plunge pool dimension. The plunge pool dimension between any slide flume exit or terminus and the opposite side of the plunge pool shall be a minimum of 20 feet (6096 mm) excluding steps.
424.1.9.2.1.3 Slide flume terminus.
424.1.9.2.1.3.1
The slide flume terminus shall be designed by the design engineer who can
demonstrate to the department's satisfaction that riders will be adequately
slowed prior to discharge so as to prevent injury or harm to the rider upon
impact with the plunge pool water. The slide terminus shall be flush
with the pool wall and located at or below the pool water level.
424.1.9.2.1.3.2 The minimum distance between any plunge pool side wall and the outer edge of any slide terminus shall be 5 feet (1524 mm). The minimum distance between adjacent slide flumes shall be 6 feet (18 288 mm).
424.1.9.2.1.3.3 A minimum length of slide flume of 10 feet (3048 mm) shall be perpendicular to the plunge pool wall at the exit end of the flumes.
424.1.9.2.1.4 Plunge pool main drains. The plunge pool shall have a minimum of one main drain with separate piping and valve to the filtration system collector tank. The velocity through the openings of the main drain grate shall not exceed 11/2 feet per second (457 mm/s) at the design flow rate of the recirculation pump. The main drain piping shall be sized to handle 100 percent of the design flow rate of the filtration system with a maximum flow velocity of 3 feet (914 mm) per second.
424.1.9.2.1.5 Plunge pool floor slope. The plunge pool floor shall slope to the main drains and the slope shall not exceed 1 in 10.
424.1.9.2.1.6 Plunge pool decks.
424.1.9.2.1.6.1 Width. The minimum width of plunge pool
decks along the exit side shall be 10 feet (3048 mm). There shall be a pool deck along the side opposite the plunge
pool weir, and this deck shall have a minimum width of 4 feet (1219 mm).
424.1.9.2.1.6.2 Curbs. All plunge
pool decks shall have a minimum 6-inch-high (152 mm) curb or adequate freeboard
to contain the water surge generated by the person entering the water via the
slide.
424.1.9.2.1.6.3 Slopes. All plunge pool decks shall slope away from the plunge pool unless the curb is located at the
outside perimeter of the deck. If the curb is located at the outside perimeter
of the deck, the plunge pool deck shall slope to the plunge pool or
pump reservoir or to deck drains which discharge to waste , or other acceptable means. All slopes shall be between 2- and
4-percent grade.
424.1.9.2.1.7 Hand holds. Hand
holds shall be provided along the sides of the plunge pool in areas where the
water depth exceeds 3 feet (914 mm), except that no hand holds shall be
required along the wall where the slide enters the pool nor shall they be
required at the pool exit.
424.1.9.2.2 Run out lanes.
424.1.9.2.2.1 Run out lanes may be utilized in lieu of a plunge pool system, provided they are constructed to the slide manufacturers specifications and are approved by the design engineer of record.
424.1.9.2.2.2 Five Eight-foot-wide (2438 mm) walkways shall be
provided adjacent to run out lanes.
424.1.9.2.2.3 Minimum water level indicator markings shall be provided on both sides of the run out trough to ensure adequate water for the safe slowing of pool patrons.
424.1.9.2.2.4 Water park personnel shall be provided at the top of the slides and at the run out.
424.1.9.2.3 Pump reservoirs. Pump reservoirs shall be made
of concrete or other impervious material with a smooth slip-resistant finish. and shall be connected to the plunge pool by a weir.
Pump reservoirs shall be for the slide pump intakes, but where properly sized may also be used as a collector
tank for the filter system. . Pump reservoir designs shall meet the
criteria of Sections 424.1.9.2.3.1 through 424.1.9.2.3.5.
424.1.9.2.3.1 Pump reservoir volume. The minimum reservoir volume shall be equal to 2 minutes of the combined flow rate in gallons per minute of all filter and slide pumps.
424.1.9.2.3.2 Pump reservoir security. Pump reservoirs shall be accessible only to authorized individuals.
424.1.9.2.3.3 Pump reservoir maintenance accessibility. Access decks shall be provided for the reservoir such that all areas are accessible for vacuuming, skimming, and maintenance. The decks shall have a minimum width of 3 feet (914 mm) and shall have a minimum slope of 3:10 away from the reservoir.
424.1.9.2.3.4 Pump reservoir slide pump intakes. The slide pump intakes shall be located in the pump reservoir and shall be designed to allow cleaning without danger of operator entrapment.
424.1.9.2.3.5 Pump reservoir main drains. The pump reservoir shall have a minimum of one main drain with separate piping and valve to the filtration system collector tank and the velocity through the openings of the main drain grates shall not exceed 11/2 feet per second (457 mm/s) at the design flow rate of the filtration system pump. The main drain piping shall be sized to handle 100 percent of design flow rate of the filtration system pump with a maximum flow velocity of 3 feet per second (914 mm/s).
424.1.9.2.3.5. The pump reservoir shall be fed by main drains
within the plunge pool itself (either in the floor or side wall). They shall
have the maximum flow velocity of 1.5 feet per second through the main drain
grating and 3 feet per second through piping to the reservoir.
424.1.9.2.4 Slide pump check valves. Slide pumps shall have check valves on all discharge lines.
424.1.9.2.5 Perimeter overflow gutters or skimmers. Plunge pools and pump reservoirs shall have perimeter overflow gutter system or skimmer which shall be an integral part of the filtration system.
424.1.9.2.5.1 Perimeter overflow gutter systems. Perimeter overflow gutter systems shall meet the requirements of Section 424.1.6.5.3.1 except that gutters are not required directly under slide flumes or along the weirs which separate plunge pools and pump reservoirs.
424.1.9.2.5.2 Surface skimmers. Surface skimmers may be used
in lieu of perimeter overflow gutters and shall be appropriately spaced and
located according to the structural design. Unless an overflow gutter system is
used, surface skimmers shall be provided in the plunge pool and in the pump
reservoir and the skimmer system shall be designed to carry 60 percent of the
filtration system design flow rate with each skimmer carrying a minimum 30 gpm
(2 L/s). All surface skimmers shall meet the requirements for NSF commercial
approval as set forth in NSF NSF/ANSI Standard 50-20071996,
Circulation System Components and Related Materials for Swimming Pools,
Spas/Hot Tubs, which is incorporated by reference in these rules, including an
equalizer valve in the skimmer and an equalizer line to the pool wall on
systems with direct connection to pump suction.
424.1.9.2.6 Water slide recirculation-filtration equipment.
424.1.9.2.6.1 Recirculation rate. The recirculation-filtration system of water slides shall recirculate and filter a water volume equal to the total water volume of the facility in a period of 3 hours or less.
424.1.9.2.6.2 Filter areas. minimum filter area requirements shall be twice the filter areas specified for the recirculation rates stipulated in Section 424.1.6.5.5.1. The filtration system shall be capable of returning the pool water turbidity to 5/10 NTU within 8 hours or less after peak bather load.
424.1.9.2.6.3 Hair and lint strainer. Any filtration system pump which takes suction directly from the plunge pool and reservoir shall have a minimum 8-inch (208 mm) diameter hair and lint strainer on the suction side of the pump.
424.1.9.2.7 Disinfection. The disinfection equipment shall be capable of feeding 12 mg/L of halogen to the continuous recirculation flow of the filtration system.
424.1.9.2.8 Slide design and
construction is the responsibility of a professional engineer licensed in
424.1.9.2.9 A lockable gate shall be provided at the stair or
ladder entrance to the slide.
424.1.9.2.10 Upon construction completion, a professional engineer licensed in
424.1.9.3 Water activity pools.
424.1.9.3.1 Water activity pools shall be designed and constructed within the limits of sound engineering practice. The design engineer may consult with the department prior to preparation and submission of engineering plans and specifications for water activity pools.
424.1.9.3.2 Water activity pools shall be constructed of concrete or other structurally rigid impervious materials with a nontoxic, smooth and slip-resistant finish. These pools shall be of such shape and design as to be operated and maintained in a safe and sanitary manner.
424.1.9.3.3 The recirculation-filtration system of water
activity pools shall be capable of achieve a minimum of one turnover every 23 hours for water activity pools over two
feet deep, and in one hour for these pools that are two feet deep or less.
424.1.9.3.4
Those portions
of the activity pool
where the water depth will not allow for the proper installation of underwater
lighting, shall be provided with six foot candles of lighting on the deck
and the water surface.
424.1.9.3.5 Fence
requirements shall be in accordance with section 424.1.7.7.
424.1.9.3.6 Play features with an overhead clearance of less
than four feet shall be blocked or barricaded to preclude children becoming
entrapped.
424.1.9.4 Wave pools.
424.1.9.4.1 Wave pools shall be designed and constructed within the limits of sound engineering practice.
424.1.9.4.2 Wave pools shall be constructed of concrete or other impervious materials with a smooth slip-resistant finish. These pools shall be of such shape and design as to be operated and maintained in a safe and sanitary manner.
424.1.9.4.3 The recirculation-filtration system of wave pools shall be capable of a minimum of one turnover every 3 hours.
424.1.9.4.4 Floors shall be sloped in accordance with the
manufacturer’s or
design engineer’s specifications, however, they shall not exceed the
slope limits of section 424.1.2.2.3.
424.1.9.5 Lazy Rriver rides.
424.1.9.5.1 Lazy Rriver
rides shall be constructed within the limits of sound engineering practice.
424.1.9.5.2 Lazy Rriver rides shall be constructed on
concrete or other impervious materials with a nontoxic, smooth and
slip-resistant finish. These rides shall be of such shape and design as to be
operated in a safe and sanitary manner.
424.1.9.5.3 The recirculation-filtration system of the lazy river ride shall be capable of a minimum of
one turnover every 3 hours.
424.1.9.5.4 The maximum water depth of the lazy river ride shall not exceed 3 feet (914 mm) unless justified to the department's satisfaction by the design engineer.
424.1.9.5.5 Decking shall be provided at the entrance and exit points as necessary to provide safe patron access but shall not be smaller than 10 feet (3048 mm) in width and length. Additional decking along the ride course is not required except that decking shall be required at lifeguard locations and emergency exit points.
424.1.9.5.6 Access and exit shall be provided at the start
and end of the ride, only, except that emergency
and additional exit locations shall be located along the ride
course as necessary to provide for the safety of the patrons.
424.1.9.5.6
Propulsion jets shall be installed in the walls of the river ride. In the
alternative, propulsion jets may be installed in the floor if they are covered by a grate
that will inhibit entrapment or injury of the pool patrons’ feet or limbs
424.1.9.6 Zero depth entry pools.
424.1.9.6.1 Zero depth entry pools shall have a continuous floor slope from the water edge to the deep end.
424.1.9.6.2 The deck level perimeter overflow system with grate shall be provided at the waters edge across the entire zero depth portion of the pool.
424.1.9.6.3 The pool deck may slope toward the pool for no more than 5 feet (1524 mm), as measured from the overflow system grate outward. Beyond this area the deck shall slope away from the pool in accordance with Section 424.1.2.2.3.
424.1.9.6.4 Barriers and
No-Entry entry,
Shallow Water signs shall be provided along the pool wall edge where
the water depth is less than 3 feet (914 mm) deep. No-entry signs shall be
slip-resistant, shall have 4-inch-high (102 mm) letters, shall be located
within 2 feet (610 mm) of the pool edge and shall be spaced no more than 15
feet (4572 mm) apart.
424.1.9.6.5 Additional inlets shall be provided in areas of less than 18 inches (457 mm) deep. The numbers and location shall be such as to double the flow rate into this area.
424.1.9.6.6 The
recirculation-filtration system shall be of a minimum of one turnover every two
hours in the area of the pool that is three feet deep or less. In the remainder
of the pool where the depth is greater than three feet, the system shall have a
maximum six hour turnover rate. The design plans submitted by the applicant shall
provide the volume of water in the pool area of three feet depth
and less, the volume of water in the pool area greater than three feet in
depth, and the total volume in the pool for determination of minimum
circulation flow. The volume calculations shall provide verification that the
correct volume of water is used to determine the minimum flow at the two hour
and the six hour flow requirements.
424.1.9.6.7 Those portions of the zero depth entry pool,
where the water depth will not allow for the proper installation of underwater
lighting, shall be provided with 6 foot candles of lighting on the deck and the
water.
424.1.9.6.8 Play structures in a zero depth entry area (in depth 0-3 feet) may be within
15 feet of the pool walls, but shall comply with sound engineering requirements
for the safety of pool patrons.
424.1.9.7 Special purpose pools.
424.1.9.7.1 General. Special purpose pool projects may deviate from the requirements of other sections of these rules provided the design and construction are within the limits of sound engineering practice. Only those deviations necessary to accommodate the special usage shall be allowed and all other aspects of the pool shall comply with the requirements of this section and with Section 424.1.2.
424.1.9.7.2 A special purpose pool may incorporate ledges which do not overhang into the pool.
424.1.9.8 Interactive water features (IWFs).
424.1.9.8.1 Waters discharged from all fountain or spray
features shall not pond on the feature floor but shall flow by gravity through
a main drain fitting to a below grade sump or
collection system which discharges to a collector tank. The minimum size of the
sump or collector tank shall be equal to
the volume of 2 minutes of the combined flow of all feature pumps and the
filter pump. Smaller tanks may be utilized if hydraulically justified by the
design engineer. Adequate access shall be provided to the sump or collector
tank. Stairs or a ladder shall be provided as needed to ensure safe entry into
the tank.
424.1.9.8.2 When an underground
sump is utilized, an An automatic
skimmer system shall be provided in the collector tank. A variable height skimmer may be
used or a custom surface skimmer device may be substituted if deemed
appropriate by both the design engineer and the department.
424.1.9.8.3 Chemical feeders shall be provided in accordance with Section 424.1.6.5;
except that the disinfection feeder shall be capable of feeding 12 ppm of free
chlorine to the filter return piping (based upon a hypothetical 30 minute turnover of the contained
volume within the system).
424.1.9.8.4 If night operation is proposed, 6 footcandles (60 lux) of light shall be provided on the pool deck and the water feature area. Lighting that may be exposed to the feature pool water shall not exceed 15 volts, shall be installed in accordance with manufacturer's specifications and be approved for such use by UL or NSF.
424.1.9.8.5 All electrical work shall comply with Chapter 27 of the Florida Building Code, Building.
424.1.9.8.6 Hydraulics.
424.1.9.8.6.1 The filter system shall filter be capable of filtering
and chemically treat treating all the entire water that
is returned to the spray features. volume of the water feature within
30-minutes. The filter system shall draft from the collector tank and
return filtered and treated water directly to the spray features.
Excess water not required by the spray features shall be returned to the
collector tank. via equally spaced inlet fittings. The flow rate
through these fittings shall not exceed 20 gpm.
424.1.9.8.6.2 The water feature pump shall draft from the collector tank.
424.1.9.8.6.3 Alternatively, the contained volume of the system may be filtered and chemically treated
based upon a 30 minute turnover of the contained volume with 100% returned
to the collector tank by manifold piping. If this alternative
is chosen, all water returned to the spray feature(s) must
also be treated with an Ultraviolet (UV) light disinfection equipment
to accomplish protozoan destruction in accordance with sound engineering and
the requirements of section 424.1.6.5.16.6. This alternative must have
the ability to feed 6 mg/L free chlorine to the feature water as it
is returned to the spray feature. The UV disinfection equipment
shall be electrically interconnected such that whenever it fails to
produce the required UV dosage, the water spray features pump(s) and flow will
be immediately stopped. The water feature pump shall draft from
the collector tank.
424.1.9.8.6.4 The flow rate through the feature nozzles of the water features shall be such as not to harm the patrons and shall not exceed 20 feet per second (6096 mm/s) unless justified by the design engineer and by the fountain system manufacturer.
424.1.9.8.6.5
An automatic water level controller shall be provided.
424.1.9.8.6.6 An overfill waste line with air gap shall be
provided.
424.1.9.8.6.7 A means
of vacuuming and completely draining the tank(s) shall be provided.
424.1.9.8.6.8 Where the filter system described in section
424.1.9.8.6.1 is utilized, a second filter system and disinfection system shall
be provided to treat the water in the collector tank when the feature/filter
pump is not in operation. Said system shall be capable of filtering the total
volume of water in the collector tank in 30 minutes and the disinfection system
shall be capable of providing 12 mg/L of disinfectant to this flow rate.
424.1.9.8.6.9 IWFs shall be fenced in the same fashion as
wading pools as noted in section 424.1.7.7. Where the IWF is at
least 50 feet from all other pools and is not designed to have any standing
water, fencing requirements should be carefully considered by the
applicant to control usage, but are not required by rule.
424.1.9.8.6.10 A minimum four foot wide wet deck area shall be provided
around all IWFs. The wet deck shall meet the requirements of section
424.1.2.2.3, however, up to 50% of the perimeter may be obstructed.
424.1.9.8.6.11 I WFs shall be constructed of concrete or other
impervious and structurally rigid material.
424.1.9.8.6.12 Floor
slopes of an IWF shall be a maximum one foot vertical in ten feet horizontal
and a minimum of one foot vertical in fifty feet horizontal.
424.1.9.8.7 Water Theme Parks: Shall meet all other aspects
of these rules for the features provided.
424.1.9.8.7.1 Rules and
regulations for water theme parks shall be posted in minimum 1-inch letters at
each entrance to the park and shall contain the following:
1.
No food, drink, glass, or animals in the pool or on the pool decks.
2. Park
operating hours ___A.M. to ___P.M.
3.
Shower before entering
4.
Do not swallow the pool water
424.1.9.8.7.2 Showers shall be provided at or near the entrance
(queue line) to a water recreation attraction.
424.1.9.8.7.3 Water theme parks are exempt from the fencing
requirements of section 424.1.3.1.9., except that pools designed for small
children shall be fenced when located within 50 feet of a pool with water
depths of 3 feet or more.
424.1.9.8.7.4 Sanitary Facilities within a water theme park
shall be as near to the water recreation attractions as prudent to ensure
patron use, but not over 200 feet walking distance from any exit of a water
attraction.
424.1.10
Modifications.
424.1.10.1
Modifications – Modifications include non-equivalent changes or additions
to the recirculation system, treatment equipment, physical structure, or
appurtenances. Replacement of the pool or spa shell is considered to be
construction of a new facility and shall be processed as such. The installation
of new decking is not considered a modification if it is installed in
conformance with Section 424.1.3.1, and deck markings are upgraded per Section
424.1.2.3. Resurfacing the pool interior to original non-toxic slip-resistant
and smooth specifications or equivalent replacement of equipment are not
considered modifications. However, the following items shall be addressed
during resurfacing projects:
424.1.10.1.1 The lip
of the gutter must be leveled to within 1/4 inch between the highest and lowest
point and the downward slope from the lip to the drain must be maintained as
originally designed or increased, but shall not exceed new construction
standards.
424.1.10.1.2 Tile step
markings must be installed meeting the requirements of Section
424.1.2.5.3.
424.1.10.1.3 Where applicable
the slope break marking must be installed meeting the requirements of Section 424.1.2.2.3.2
and the safety line must be installed two feet before the marking.
424.1.10.1.4 Depth
markers and NO DIVING markers must be installed in accordance with Section
424.1.2.3.
424.1.10.1.5 The pool
ladder must have a three to six inch clearance from the pool wall. New cross
braced ladder(s) shall be installed in place of non-cross braced ladder(s) in
conformance with Section 424.1.2.5.1 during a pool re-surfacing
424.1.10.1.6 Should resurfacing works affect the step riser
heights, no riser shall exceed 12 inches and the intermediate risers shall be
made uniform.
424.1.10.1.7 When
fiberglass is used to resurface a pool any existing tile shall not be covered
by the fiberglass finish.
424.1.10.1.8 The
applicable governing body shall be notified in writing of any proposed pool
resurfacing or upgrades to decking at least 10 days prior to commencement. The
notification shall include an itemized list of all proposed work that is to be
performed, the license number of the contractor selected and shall indicate
that all work will meet the requirements of this section.
424.1.10.1.9 Recessed treads that protrude from the pool
wall shall be removed and replaced with a cross braced ladder or reconstructed
to meet the requirements of Section 424.1.2.5.2.
424.1.10.2 The painting of pools shall not be considered a
modification provided the following conditions are met:
(a) Only paints designated by the
manufacturer as pool paints are used.
(b) All step stripes, slope break
markers and safety line, and depth and NO DIVING markings shall be provided to
comply with the applicable provision(s) of this section.
424.1.10.3 The
installation of copper or copper/silver ionization units and ozone generators
capable of producing less than a pool water ozone contact concentration of 0.1
milligrams per liter (mg/L). shall not be considered a pool modification
provided compliance with when the following is met:
(a) The ionization or ozone
generator unit complies with paragraph 64E-9.007(16)(e), F.A.C.
(b) The manufacturer provides one
set of signed and sealed engineering drawings indicating the following:
1. The unit does not interfere with
the design flow rate.
2. The unit and the typical
installation meet the requirements of the National Electrical Code.
3. A copper test kit and
information regarding the maximum allowed copper and silver level and the
minimum required chlorine level shall be available to the pool owner.
4. The unit shall meet the requirements of the NSF/ANSI
standard 50-2007.
(c) At least 7 days before At the time of
installation, the installer will provide a photocopy of the above drawings and
a letter of intent identifying the pool on which the unit is to be installed.
(d) Upon completion of the installation, a professional
engineer or electrician licensed in the State of Florida shall provide a
letter, to the county health department, indicating the unit was properly
installed in accordance with the typical drawings, the National Electrical Code
and with local codes.
2007
Revise Section 403.8 to read as follows:
403.8 Sanitary
facilities for public swimming pools. Swimming pools with a bathing load
of 20 persons or less may utilize a unisex restroom. Pools with bathing loads
of 40 persons or less may utilize two unisex restrooms or meet the requirement
of Table 403.8. Unisex restrooms shall meet all the requirements for materials,
drainage and signage as indicated in sections 424.1.6.1.1 through 424.1.6.1.4
of the FBC, Building. Each shall include
a water closet, a diaper change table, a urinal, and a lavatory. Pools with a
bathing load larger than 40 persons shall provide separate Separate sanitary facilities shall be provided and labeled for each sex. And The entry doors of all restrooms shall
be located within a 200-foot (60 960 mm) walking distance of the nearest
water’s edge of each pool served by the facilities.
Exception: Where a swimming pool serves only a designated group of
residential dwelling units and not the general public, poolside sanitary
facilities are not required if all living units are within a 200 foot horizontal radius of the nearest water's edge, are not
over three stories in height and are each equipped with private sanitary
facilities.
403.8.1 Required fixtures. Fixtures shall be
provided as indicated on Table 403.8. The
fixture count of Table 403.8 is deemed to be adequate for the pool and pool
deck area that is up to three times the area of the pool surface provided. An additional set of fixtures
shall be provided in the men's restroom for every 7,500 5000 square feet or major
fraction thereof for pools greater than 10,000 square feet. Women's restrooms
shall have a ratio of three to two water closets provided for women as the
combined total of water closets and urinals provided for men.
Lavatory
counts shall be equal.
403.8.2 Outside access. Outside access to facilities shall be provided
for bathers at outdoor pools. Where the restrooms are located
within an adjacent building and the restroom doors do not open to the outside, the restroom doors
shall be within 50 feet of the buildings exterior door. and if
they If the restrooms
are not visible from any portion of the pool deck, signs shall be posed showing
directions to the facilities. Directions shall be legible from any portion of
the pool deck; letters shall be a minimum of 1-inch high.
403.8.3 Sanitary facility floors. Floors of
sanitary facilities shall be constructed of concrete or other nonabsorbent
materials, shall have a smooth, slip-resistant finish, and shall slope to floor
drains. Carpets, duckboards and footbaths are prohibited. The intersection
between the floor and walls shall be coved where either floor or wall is not made of waterproof
materials such as tile or vinyl.
.
TABLE 403.8
PUBLIC SWIMMING POOL - FIXTURES REQUIRED FIXTURES COUNT
SIZE MEN'S RESTROOMS WOMEN'S RESTROOMS
Urinals WC Lavatory
WC Lavatory
0 - 2500 sq ft 1 1 1 1 1
2501 - 5000 sq ft 2 1 1 5 1
5001 - 7500 sq ft 2 2 2 6 2
7501 - 10,000 sq ft 3 3 2 3
9 8 3
For SI: 1 square foot = 0.0929
m2.