Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL4537-R4
Application Type Revision
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Dixieland Metals of Alabama, LLC.
Address/Phone/Email 378 Eastland Road
Dothan, AL 36304
(334) 678-0038
flvalidation@yahoo.com
 
Authorized Signature Kennon Whaley
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 05/08/2021
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL4537_R4_COI_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-SS.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
FM 44711992
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/18/2017
Date Validated 10/08/2017
Date Pending FBC Approval 10/12/2017
Date Approved 12/12/2017
Date Revised 12/18/2020
 
Summary of Products
FL # Model, Number or Name Description
4537.1 26 Ga. PBR Roof Min. 26 Ga. PBR Roof Deck Panel over 16GA open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +60.0PSF/-47.5PSF
 Other: -47.5 psf @ 5'-0" fastener spacing. +60.0 psf @ 5'-0" o.c. Install per manufacturers details, in compliance with Florida Building Code 2017 6th ed. Not for use in HVHZ Zones.
Installation Instructions
 FL4537_R4_II_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-ssa.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4537_R4_AE_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-ssa.pdf
 Created by Independent Third Party: Yes
4537.2 26 Ga. Tuff Rib Min. 26 Ga. Tuff Rib Roof Panel over 16GA open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-96.8PSF
 Other: -96.8 psf @ 2'-0" o.c. fastener spacing. Panel must be installed per manufacturers details, and in compliance with Florida Building Code 2017 6th ed. Not for use in HVHZ Zones.
Installation Instructions
 FL4537_R4_II_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-ssa.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4537_R4_AE_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-ssa.pdf
 Created by Independent Third Party: Yes
4537.3 29 Ga. Tuff Rib Min. 29 Ga. Tuff Rib Roof Panel over 16GA open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-84.3PSF
 Other: -84.3 psf @ 2'-0" o.c. fastener spacing. Panel must be installed per manufacturers details and in compliance with Florida Building Code 2017 6th ed. Not for use in HVHZ Zones.
Installation Instructions
 FL4537_R4_II_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-ssa.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4537_R4_AE_FL 4537 DIXIELAND METALS OF AL-FINAL REPORT-ssa.pdf
 Created by Independent Third Party: Yes
 