18525.1 |
1.5 AL 0.032 MECHANICAL LOCK |
OVER 15/32" APA Plywood Grade C-D
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +n/a/-123psf Other: -123psf@ 6"o.c.
-59.75psf@ 24"o.c.
Install per manufacturers detail and in compliance w/CURRENT FBC NOT FOR USE IN HVHZ. |
Installation Instructions FL18525_R2_II_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL18525_R2_AE_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Created by Independent Third Party: Yes |
|
18525.2 |
1.5 MECHANICAL LOCK |
24GA mechanical lock over 15/32" APA Plywood-Non HVHZ.
Use 19/32" APA Plywood for HVHZ new construction. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +n/a/--123psf Other: -123psf@ 6"o.c.
-59.75psf@ 24"o.c.
Install per manufacturers detail and in compliance w/CURRENT FBC 19/32" APA plywood for HVHZ new construction.
For use in HVHZ. |
Installation Instructions FL18525_R2_II_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL18525_R2_AE_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Created by Independent Third Party: Yes |
|
18525.3 |
1.5 NAIL STRIP |
24GA OVER 15/32" APA PLYWOOD-Non HVHZ.
Use 19/32" APA Plywood for HVHZ new construction. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +n/a/--116psf Other: -116psf @ 6-1/2"
12"o.c. in pan spacing.
-78.5psf@ 11"o.c. panel slot fastening. Install per manufacturers detail and in compliance with FBC
For use in HVHZ. |
Installation Instructions FL18525_R2_II_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL18525_R2_AE_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Created by Independent Third Party: Yes |
|
18525.4 |
1.5 SNAP LOCK |
24GA OVER 15/32" APA PLYWOOD-Non HVHZ.
Use 19/32" APA Plywood for HVHZ new construction. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +n/a/-116psf Other: -116pf @ 6"o.c. clip spacing 12"o.c
-108psf fastening at 24"o.c.
Install per manufacturers detail in compliance w/CURRENT FBC Use 19/32" APA Plywood for HVHZ new construction. For use in HVHZ. |
Installation Instructions FL18525_R2_II_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL18525_R2_AE_FL18525_R2_II_FL18525_R1_AE_FL 18525 Mullets Aluminum - CURRENT FBC Code Eval Report and Details SS.pdf Created by Independent Third Party: Yes |