FL # FL20103-R0
Application Type New
Code Version 2014
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Master Wall Inc.®
Address/Phone/Email PO Box 397
Fortson, GA 31808
(800) 755-0825
dennisdeppner@masterwall.com
 
Authorized Signature Dennis Deppner
dennisdeppner@masterwall.com
 
Technical Representative Dennis Deppner
Address/Phone/Email 211 Quiet Creek Ct.
Chelsea, MI 48118
(800) 760-2861
tech@masterwall.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Exterior Insulation Finish System
 
Compliance Method Evaluation Report from a Product Evaluation Entity
 
Evaluation Entity IAPMO UES
Quality Assurance Entity IAPMO Quality Control Consultants, LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Gary W. Walker
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL20103_R0_COI_CERTIFICATE OF INDEPENDENCE IAPMO UES.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM C 11772008
ASTM C 5782008
ASTM E 25702007
ASTM E 842009
ASTM E 962005
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option C
 
Date Submitted 03/18/2016
Date Validated 08/22/2016
Date Pending FBC Approval
Date Approved 08/22/2016
Date Revised 01/18/2018
 
Summary of Products
FL # Model, Number or Name Description
20103.1 Master Wall EIF Systems Rollershield Drainage EIFS
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +95/-75
 Other: system designs vary
Installation Instructions
 FL20103_R0_II_rollershieldlablong2016.pdf
 Verified By: IAPMO UES
 Created by Independent Third Party: 
Evaluation Reports
 FL20103_R0_AE_MasterWallEIFSER_0433.pdf
20103.2 Master Wall EIF Systems Aggre-flex EIFS
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +95/-75
 Other:  
Installation Instructions
 FL20103_R0_II_aggreflexlong2016.pdf
 Verified By: IAPMO UES
 Created by Independent Third Party: 
Evaluation Reports
 FL20103_R0_AE_MasterWallEIFSER_0433.pdf
20103.3 Master Wall EIF Systems Aggre-flex Drainage EIFS
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +60/-35
 Other:  
Installation Instructions
 FL20103_R0_II_aggreflexdrainagelong2016.pdf
 Verified By: IAPMO UES
 Created by Independent Third Party: 
Evaluation Reports
 FL20103_R0_AE_MasterWallEIFSER_0433.pdf
20103.4 Master Wall EIF Systems QRW1 Drainage EIFS
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +55/-30
 Other:  
Installation Instructions
 FL20103_R0_II_qrwidrainagesubmittal (1).pdf
 Verified By: IAPMO UES
 Created by Independent Third Party: 
Evaluation Reports
 FL20103_R0_AE_MasterWallEIFSER_0433.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex