Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL23157-R1
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Nick Delfino
Address/Phone/Email 1500 N. University Drive
Suite 201-G
Coral Springs, FL 33071
(954) 461-7055
ndelfino@petersenmail.com
 
Category Panel Walls
Subcategory Soffits
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Scott Wolters, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL23157_R1_COI_FL 23157_PAC-CLAD STEEL SOFFIT 12IN X 24GA-BINDER COMPLETE.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM 15922012
ASTM E3302002
TAS 100(A)1995
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL23157_R1_Equiv_Equivalency of code letter 23157, 23225, 23953.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/26/2020
Date Validated 12/21/2020
Date Pending FBC Approval 01/03/2021
Date Approved 02/09/2021
Date Revised 07/11/2023
 
Summary of Products
FL # Model, Number or Name Description
23157.1 Flush Panel (.032") 12" wide x .032" Aluminum Soffit Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-80
 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48", see load table attached.
Installation Instructions
 FL23157_R1_II_FL 23157_PAC-CLAD_0.032 ALUM 12IN SOFFIT PANEL-BINDER COMPLETE.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23157_R1_AE_FL 23157_PAC-CLAD_0.032 ALUM 12IN SOFFIT PANEL-BINDER COMPLETE.pdf
 Created by Independent Third Party: Yes
23157.2 Flush Panel (.040") 12" wide x .040" Aluminum Soffit Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-290
 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48", see load table attached.
Installation Instructions
 FL23157_R1_II_FL 23157_PAC-CLAD SOFFIT_0.40 ALUM 12IN OVER 16GA-BINDER COMPLETE.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23157_R1_AE_FL 23157_PAC-CLAD SOFFIT_0.40 ALUM 12IN OVER 16GA-BINDER COMPLETE.pdf
 Created by Independent Third Party: Yes
23157.3 Flush Panel (22 ga.) 12" wide x 22 ga. Steel Soffit Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-210
 Other: 24", 30", 36", 42", 48", 54" and 60", see load table attached.
Installation Instructions
 FL23157_R1_II_FL 23157_PAC-CLAD 12 X 22GA STEEL SOFFIT-BINDER COMPLETE.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23157_R1_AE_FL 23157_PAC-CLAD 12 X 22GA STEEL SOFFIT-BINDER COMPLETE.pdf
 Created by Independent Third Party: Yes
23157.4 Flush Panel (24 ga.) 12" wide x 24 ga. Steel Soffit Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-165
 Other: 24", 30", 36", 42", 48", 54" and 60", see load table attached.
Installation Instructions
 FL23157_R1_II_FL 23157_PAC-CLAD STEEL SOFFIT 12IN X 24GA-BINDER COMPLETE.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23157_R1_AE_FL 23157_PAC-CLAD STEEL SOFFIT 12IN X 24GA-BINDER COMPLETE.pdf
 Created by Independent Third Party: Yes
23157.5 PAC-850 Aluminum Soffit PAC-850 Aluminum Soffit x 12" wide, .032" Aluminum Soffit, Solid, Fully-Vented or 1/2 Vented.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-110.9
 Other: -24.27 psf @ 4'-0" o.c. -110.93 psf @1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL23157_R1_II_PAC-CLAD 850- SOFFIT_0.032 ALUM 12IN OVER 22GA-BINDER COMPLETE_r2.pdf
 Verified By: Terrance E. Wolfe, P.E. 44923
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23157_R1_AE_PAC-CLAD 850- SOFFIT_0.032 ALUM 12IN OVER 22GA-BINDER COMPLETE_r2a.pdf
 Created by Independent Third Party: Yes
23157.6 PAC-850 Aluminum Soffit PAC-850 Aluminum Soffit x 12" wide, .032" Aluminum Soffit, Solid, Fully-Vented or 1/2 Vented.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-100
 Other: Approved for use in HVHZ
Installation Instructions
 FL23157_R1_II_PAC-CLAD 850_ 0.032 ALUM SOFFIT-HVHZ-r2.pdf
 Verified By: C. K. Brasher, P.E. 11140
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23157_R1_AE_FL 23157 PETERSEN 850 HVHZ SOFFIT ALUMINUM-SS.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe