21873.1 |
6/0 x 8/0 Tiffany Ashville Double ARCH top w/TDL |
6/0 x 8/0 Tiffany Ashville Double ARCH top w/TDL |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the 5th edition (2014) FBC/FRC has been employed. |
Installation Instructions FL21873_R1_II_DSA0005_Rev0_Asheville-Double-ArchTop-TDL.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R1_AE_PERNo2483_Rev0_416-1002_ss.pdf Created by Independent Third Party: Yes |
|
21873.2 |
7/0 x 8/0 Double Full Lite/2 Panels |
7/0 x 8/0 Double Full Lite/2 Panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the 5th edition (2014) FBC/FRC has been employed. |
Installation Instructions FL21873_R1_II_DSA0003_Rev0_ImpactDouble7080.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R1_AE_PERNo2483_Rev0_416-1002_ss.pdf Created by Independent Third Party: Yes |
|
21873.3 |
Alexandria 9 Lite Single Door with Sidelites and Transom |
Alexandria 9 Lite Single Door with Sidelites and Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the 5th edition (2014) FBC/FRC has been employed. |
Installation Instructions FL21873_R1_II_DSA0002_Rev0_Alexandria-9Lite-Sidelites-Transom.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R1_AE_PERNo2483_Rev0_416-1002_ss.pdf Created by Independent Third Party: Yes |
|
21873.4 |
Double Full View Door with Full View Transom |
Double Full View Door with Full View Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the 5th edition (2014) FBC/FRC has been employed. |
Installation Instructions FL21873_R1_II_DSA0001_Rev0_ImpactDouble6010DoorXX.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R1_AE_PERNo2483_Rev0_416-1002_ss.pdf Created by Independent Third Party: Yes |
|
21873.5 |
Full View Door with Full View Sidelites and Transom |
Full View Door with Full View Sidelites and Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the 5th edition (2014) FBC/FRC has been employed. |
Installation Instructions FL21873_R1_II_DSA0004_Rev0_ImpactSingleFullLite-Sidelites-Transom.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R1_AE_PERNo2483_Rev0_416-1002_ss.pdf Created by Independent Third Party: Yes |