24423.1 |
5-V-Crimp (.032" min.) |
.032" (min.) Aluminum over 1/2" (min.) Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100218 5-V-Crimp .032 Aluminum over plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100218 5-V-Crimp .032 Aluminum over plywood.pdf |
|
24423.2 |
5-V-Crimp (24 ga. min.) |
24 Ga. (min.) Steel over 1/2" (min.) Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100217 5-V-Crimp 24 ga. Steel over plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100217 5-V-Crimp 24 ga. Steel over plywood.pdf |
|
24423.3 |
Edge-Loc 1.0 (24 ga.) |
24 Ga. Steel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100216 Edge-Loc 1.0 24 Ga. Steel over Plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100216 Edge-Loc 1.0 24 Ga. Steel over Plywood.pdf |
|
24423.4 |
PAC-150 (.032") |
.032" Aluminum over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-166.75 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100215 PAC-150 Panel .032 Aluminum over Plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100215 PAC-150 Panel .032 Aluminum over Plywood.pdf |
|
24423.5 |
PAC-150 (24 ga.) |
24 Ga. Steel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-136.75 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100214 PAC-150 Panel 24 Ga. Steel over Plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100214 PAC-150 Panel 24 Ga. Steel over Plywood.pdf |
|
24423.6 |
SNAP-CLAD (.032") |
.032" aluminum over steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-174.25 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.10 SNCLD .032 aluminum over steel.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.10 SNCLD .032 aluminum over steel.pdf |
|
24423.7 |
SNAP-CLAD (.032") |
.032" aluminum over 1/2" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.50 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100212 Snap-Clad Panel .032 Aluminum over Plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100212 Snap-Clad Panel .032 Aluminum over Plywood.pdf |
|
24423.8 |
SNAP-CLAD (.040") |
.040" aluminum over 5/8" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-174.25 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_17100213 Snap Clad .040 x 16 and 18 Wide Aluminum over Wood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_17100213 Snap Clad .040 x 16 and 18 Wide Aluminum over Wood.pdf |
|
24423.9 |
SNAP-CLAD (24 ga.) |
24 ga. steel over 1/2" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-144.25 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.11 SNCLD 24 steel over wood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.11 SNCLD 24 steel over wood.pdf |
|
24423.10 |
SNAP-CLAD (24 ga.) |
24 ga. steel over steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-181.75 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.09 SNCLD 24 steel over steel.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.09 SNCLD 24 steel over steel.pdf |
|
24423.11 |
Tite-Loc Plus (.032") |
.032" aluminum over 5/8" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-174.25 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.07 TLP .032 aluminum over wood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.07 TLP .032 aluminum over wood.pdf |
|
24423.12 |
Tite-Loc Plus (.032") |
.032" aluminum over steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-204.25 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.08 TLP .032 aluminum over steel.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.08 TLP .032 aluminum over steel.pdf |
|
24423.13 |
Tite-Loc Plus (24 ga.) |
24 ga. steel over steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-196.75 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.05 TLP 24 steel over steel.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.05 TLP 24 steel over steel.pdf |
|
24423.14 |
Tite-Loc Plus (24 ga.) |
24 ga. steel over 5/8" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-204.25 Other: Interpolation and the elimination of a Class "A" fire barrier are permissible outside the HVHZ unless otherwise specified in the building code. For information on slopes less than 2:12 please contact PAC's technical department. |
Installation Instructions FL24423_R0_II_171002.06 TLP 24 steel over wood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL24423_R0_AE_171002.06 TLP 24 steel over wood.pdf |