22633.1 |
HPC Steel-edge Steel Side-Hinged Door Unit |
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is required. Door top rails stamped "HPC". See DWG-MA-FL0221 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.01.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0221.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514008.pdf Created by Independent Third Party: Yes |
|
22633.2 |
HPC Steel-edge Steel Side-Hinged Door Unit |
6'-8" Impact Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is not required. Door top rails stamped "HPC". See DWG-MA-FL0223 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.04.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0223.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514008.pdf Created by Independent Third Party: Yes |
|
22633.3 |
Steel-edge Steel Side-Hinged Door Unit |
8'-0" Opaque I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +48/-48 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When impact resistance is required, hurricane protective system is not required on doors, but is required on sidelites. See DWG-MA-FL0224 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.06.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0224.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514007.pdf Created by Independent Third Party: Yes |
|
22633.4 |
Steel-edge Steel Side-Hinged Door Unit |
8'-0" Glazed I/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-45 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When impact resistance is required, hurricane protective system is required. See DWG-MA-FL0225 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.07.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0225.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514007.pdf Created by Independent Third Party: Yes |
|
22633.5 |
Steel-edge Steel Side-Hinged Door Unit |
8'-0" Glazed O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When impact resistance is required, hurricane protective system is required. See DWG-MA-FL0225 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.07.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0225.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514007.pdf Created by Independent Third Party: Yes |
|
22633.6 |
Steel-edge Steel Side-Hinged Door Unit |
8'-0" Impact Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When impact resistance is required, hurricane protective system is not required. See DWG-MA-FL0226 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.08.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0226.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514007.pdf Created by Independent Third Party: Yes |
|
22633.7 |
Steel-edge Steel Side-Hinged Door Unit |
6'-8" 3/4-Lite Glazed I/S or O/S Single or Double w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is required. See DWG-MA-FL0219 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.03.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0219.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514008.pdf Created by Independent Third Party: Yes |
|
22633.8 |
Steel-edge Steel Side-Hinged Door Unit |
6'-8" Impact Glazed I/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-45 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is not required. See DWG-MA-FL0222 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.05.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0222.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514008.pdf Created by Independent Third Party: Yes |
|
22633.9 |
Steel-edge Steel Side-Hinged Door Unit |
6'-8" Impact Glazed O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is not required. See DWG-MA-FL0222 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.05.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0222.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514008.pdf Created by Independent Third Party: Yes |
|
22633.10 |
Steel-edge Steel Side-Hinged Door Unit |
6'-8" Opaque I/S or O/S Single Door Unit |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is not required. See DWG-MA-FL0218 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0218.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514010.pdf Created by Independent Third Party: Yes |
|
22633.11 |
Steel-edge Steel Side-Hinged Door Unit |
6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is not required on doors, but is required on sidelites. See DWG-MA-FL0218 for details. |
Certification Agency Certificate FL22633_R0_C_CAC_NI013762.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22633_R0_II_FL0218.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22633_R0_AE_514008.pdf Created by Independent Third Party: Yes |