Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL30339-R0
Application Type New
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Quicken Steel
Address/Phone/Email 188 Georgia Pacific Dr
Claxton, GA 304171
(912) 549-4050
rocky@quickensteel.com
 
Authorized Signature Rocky Phillips
rocky@quickensteel.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report LOCKE BOWDEN, P.E.
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 08/03/2022
Validated By Diane Marotta, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL30339_R0_COI_CERT OF INDEPEND LOCKE.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/16/2019
Date Validated 08/16/2019
Date Pending FBC Approval 08/21/2019
Date Approved 10/15/2019
Date Revised 09/02/2020
 
Summary of Products
FL # Model, Number or Name Description
30339.1 QuickLok PL-100 .032 Aluminum over plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--182.5
 Other: -182.5PSF@5-1/4"o.c.W/Adhesive, -57.62PSF 5-1/4"O.C. W/OUT Adhesive.Install per manufacturer's details and in accordance with FBC. Not for use in HVHZ.
Installation Instructions
 FL30339_R0_II_PL-100 QUICKLOK .032 ALUMINUM-ssn.pdf
 Verified By: Intertek Testing Services NA Inc (Elm)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R0_AE_PL-100 QUICKLOK .032 ALUMINUM-ssn.pdf
 Created by Independent Third Party: Yes
30339.2 QuickLok PR-100 26GA NAIL STEEL over PLYWOOD
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--88PSF
 Other: -57.62PSF@5-1/4" O.C. FASTENER SPACING W/OUT SEALANT, -88PSF@5-1/4" FASTENER SPACING W/ SEALANT. INSTALL PER MANUFACTURERS DETAILS AND IN ACCORDANCE WITH FBC. NOT FOR USE IN HVHZ.
Installation Instructions
 FL30339_R0_II_QUICKLOK PR-100 26GA NAIL STRIP Steel-ssn.pdf
 Verified By: Intertek Testing Services NA Inc (Elm)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R0_AE_QUICKLOK PR-100 26GA NAIL STRIP Steel-ssn.pdf
 Created by Independent Third Party: Yes
30339.3 QuickRib PR-5 26ga Steel Rib Panel over Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123.5
 Other: -123.5psf@9-9-9-9 fastening pattern @ 12o.c. -82.26psf@ 9-9-9-9 fastening pattern @ 24"o.c. Install per manufacturer's details and in accordance with FBC. Not for use in HVHZ.
Installation Instructions
 FL30339_R0_II_PR-75 QuickRib 26GA Steel Rib-ssn.pdf
 Verified By: LOCKE BOWDEN, P.E. FL 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R0_AE_PR-75 QuickRib 26GA Steel Rib-ssn.pdf
 Created by Independent Third Party: Yes
30339.4 QuickSeam PS-175 26GA Steel Snap Lock over Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: -93.5psf@12"o.c. clip spacing. -63.5psf@ 16"o.c, clip spacing Install per manufacturer's details and in accordance with FBC. Not for use in HVHZ.
Installation Instructions
 FL30339_R0_II_PS-175 26GA SNAP LOCK-LOGO-ssn.pdf
 Verified By: Intertek Testing Services NA Inc (Elm)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R0_AE_PS-175 26GA SNAP LOCK-LOGO-ssn.pdf
 Created by Independent Third Party: Yes
30339.5 QuickSeam PS-175 Min. .032 Aluminum Snap Lock
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5
 Other: -108.5 psf @ 18"o.c clip spacing. Install per manufacturer's details and in accordance with FBC. Not for use in HVHZ.
Installation Instructions
 FL30339_R0_II_QUICKSEAM PS-175-.032 ALUMIN SNAP LOCK-ssn.pdf
 Verified By: Intertek Testing Services NA Inc (Elm)
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R0_AE_QUICKSEAM PS-175-.032 ALUMIN SNAP LOCK-ssn.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe