Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL4149-R5
Application Type Revision
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Dixieland Metals of Alabama, LLC.
Address/Phone/Email 378 Eastland Road
Dothan, AL 36304
(334) 678-0038
flvalidation@yahoo.com
 
Authorized Signature Kennon Whaley
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 05/08/2022
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL4149_R5_COI_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/07/2017
Date Validated 10/08/2017
Date Pending FBC Approval 10/12/2017
Date Approved 12/12/2017
Date Revised 12/18/2020
 
Summary of Products
FL # Model, Number or Name Description
4149.1 26 Ga. PBR Min. 26 Ga. PBR Roof Panel over Min. 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-56.75PSF
 Other: -56.75 psf @ 24" o.c fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL4149_R5_II_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4149_R5_AE_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Created by Independent Third Party: Yes
4149.2 26 Ga. Snap Lock 1 3/4" Snap Lock Min. 26 Ga. 14" Wide Roof Panel over Min. 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-64.25PSF
 Other: -64.25 psf @ 24" o.c. clip spacing. Install per manufacturers details and in compliance with FBC 2014. Not for use in HVHZ Zones.
Installation Instructions
 FL4149_R5_II_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4149_R5_AE_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Created by Independent Third Party: Yes
4149.3 26Ga. Tuff Rib Roof Panel Min. 26 Ga. Tuff Rib over Min. 15/32" APA Plywood Not for use in HVHZ.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-146.0PSF
 Other: 26Ga.-86.75 psf @ 24" o.c. fastener pattern Type A. -146.0 psf @ 12" o.c. fastener pattern Type B. 29Ga.-45psf@24"o.c and -157.5psf@12"o.c. Panels must be installed per the manufacturers details and in compliance with FBC 2014. Not for use in HVHZ Zones.
Installation Instructions
 FL4149_R5_II_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4149_R5_AE_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Created by Independent Third Party: Yes
4149.4 29Ga. Tuff Rib Roof Panel Min. 29Ga. Tuff Rib over 1x4 SYP wood purlins over shingles(optional) over 15/32" APA plywood. Not for use in HVHZ.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-157.5
 Other: 29Ga.-45psf@24"o.c and -157.5psf@12"o.c. Panels must be installed per the manufacturers details and in compliance with FBC 2014. Not for use in HVHZ Zones.
Installation Instructions
 FL4149_R5_II_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4149_R5_AE_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Created by Independent Third Party: Yes
4149.5 7/8" Nail Strip 24 Ga. Roof Panel 24 Ga. over 15/52" APA Plywood. Not for use in HVHZ.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-108.5
 Other: -56psf @ 15-9/16" o.c. spacing and -108.5psf @ 5-3/16" o.c. spacing. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL4149_R5_II_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4149_R5_AE_FL 4149 DIXIELAND METAL OF ALABAMA_Report_ssr.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe