Product Approval Menu > Application Detail
 
FL # FL17700-R4
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Whirlwind Steel Buildings
Address/Phone/Email 8234 Hansen Road
Houston, TX 77075
(832) 553-4659
wwsb.technical.contacts@whirlwindsteel.com
 
Authorized Signature Ronald Mays
wwsb.technical.contacts@whirlwindsteel.com
 
Technical Representative Jeremy Mathews
Address/Phone/Email 8234 Hansen Road
Houston, TX 77075
(832) 553-4811
wwsb.technical.contacts@whirlwindsteel.com
 
Quality Assurance Representative Ronald H Mays
Address/Phone/Email 8234 Hansen Road
Houston, TX 77075
(832) 553-4659
wwsb.technical.contacts@whirlwindsteel.com
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Lenard Gabert & Associates
Quality Assurance Contract Expiration Date 05/03/2025
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL17700_R4_COI_Letter of Certification.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
FM 44711992
TAS 1102000
TAS 1252003
TAS 2011994
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/21/2023
Date Validated 10/13/2023
Date Pending FBC Approval 10/21/2023
Date Approved 12/12/2023
 
Summary of Products
FL # Model, Number or Name Description
17700.1 Low Rib X Roof Panel 26 Ga. Low Rib X Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +52.1 psf/-135.3psf
 Other: +52.1 psf @ 5'-0" o.c. -49.5 psf @ 5'-0" o.c. -135.3 psf @ 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17700_R4_II_26 Ga. Low Rib X Roof Panel.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_26 Ga. Low Rib X Roof Panel.pdf
 Created by Independent Third Party: Yes
17700.2 Sturdi-Rib X Roof Panel 29 Ga. Sturdi-Rib X Roof Panel over 1x4 Wood Purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0psf
 Other: -78.5 psf @ 24" o.c. -116.0 psf @ 12" o.c. Install per manufacturer's details. Not for us in HVHZ Zones.
Installation Instructions
 FL17700_R4_II_29 Ga. Sturdi-Rib X Roof Panel.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_29 Ga. Sturdi-Rib X Roof Panel.pdf
 Created by Independent Third Party: Yes
17700.3 Super Seam II Roof Panel 24 Ga. Super Seam II Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-46.9 psf
 Other: -18.2 psf @ 5'-0" o.c. -46.9 psf @ 1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17700_R4_II_24 Ga. Super Seam II Roof Panel.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_24 Ga. Super Seam II Roof Panel.pdf
 Created by Independent Third Party: Yes
17700.4 Super Seam-Plus Roof Panel 24 Ga. Super Seam-Plus Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-160.0psf
 Other: Table A: -30.0 psf @ 5'-0" o.c. -85.0 psf @ 1'-0" o.c. Table B: -48.3 psf @ 5-0" o.c. -160.0 psf @ 1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17700_R4_II_24 Ga. Super Seam-Plus Roof Panel.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_24 Ga. Super Seam-Plus Roof Panel.pdf
 Created by Independent Third Party: Yes
17700.5 Super Span X Roof Panel 26 Ga. Super Span X Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +52.1 psf/-135.3psf
 Other: +52.1 psf @ 5'-0" o.c. -46.9 psf @ 5'-0" -135.3 psf @ 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17700_R4_II_26 Ga. Super Span X Roof Panel.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_26 Ga. Super Span X Roof Panel.pdf
 Created by Independent Third Party: Yes
17700.6 Super Span X Steel Roof Panel System Super Span X Steel Roof Panel System Over Open Framing
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-60 psf
 Other:  
Installation Instructions
 FL17700_R4_II_Super Span X Roof Panel HVHZ Installation Details.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_24 Ga. Super Span X Roof Panel HVHZ.pdf
 Created by Independent Third Party: Yes
17700.7 Weather Lok 16" Steel Roof Panel Weather Lok 16" Steel Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-42.8 ps
 Other:  
Installation Instructions
 FL17700_R4_II_Weather Lok 16 Steel Roof Panel HVHZ.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_Weather Lok 16 Steel Roof Panel HVHZ.pdf
 Created by Independent Third Party: Yes
17700.8 Weather Lok Roof Panel 24 Ga. Weather Lok Roof Panel over open framning
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-109.3psf
 Other: Triple Lock: -46.9 psf @ 5'-0" o.c. -96.3 psf @ 2'-0" o.c. Quad Lock: -57.3 psf @ 5'-0" o.c. -109.3 psf @ 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17700_R4_II_24 Ga. Weather Lok Roof Panel.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17700_R4_AE_24 Ga. Weather Lok Roof Panel.pdf
 Created by Independent Third Party: Yes
 