| 17700.1 |
Low Rib X Roof Panel |
26 Ga. Low Rib X Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +52.1 psf/-135.3psf Other: +52.1 psf @ 5'-0" o.c. -49.5 psf @ 5'-0" o.c. -135.3 psf @ 2'-0" o.c.
Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17700_R4_II_26 Ga. Low Rib X Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_26 Ga. Low Rib X Roof Panel.pdf Created by Independent Third Party: Yes |
|
|
| 17700.2 |
Sturdi-Rib X Roof Panel |
29 Ga. Sturdi-Rib X Roof Panel over 1x4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -78.5 psf @ 24" o.c. -116.0 psf @ 12" o.c. Install per manufacturer's details. Not for us in HVHZ Zones. |
Installation Instructions FL17700_R4_II_29 Ga. Sturdi-Rib X Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_29 Ga. Sturdi-Rib X Roof Panel.pdf Created by Independent Third Party: Yes |
|
|
| 17700.3 |
Super Seam II Roof Panel |
24 Ga. Super Seam II Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-46.9 psf Other: -18.2 psf @ 5'-0" o.c. -46.9 psf @ 1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17700_R4_II_24 Ga. Super Seam II Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_24 Ga. Super Seam II Roof Panel.pdf Created by Independent Third Party: Yes |
|
|
| 17700.4 |
Super Seam-Plus Roof Panel |
24 Ga. Super Seam-Plus Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-160.0psf Other: Table A: -30.0 psf @ 5'-0" o.c. -85.0 psf @ 1'-0" o.c.
Table B: -48.3 psf @ 5-0" o.c. -160.0 psf @ 1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17700_R4_II_24 Ga. Super Seam-Plus Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_24 Ga. Super Seam-Plus Roof Panel.pdf Created by Independent Third Party: Yes |
|
|
| 17700.5 |
Super Span X Roof Panel |
26 Ga. Super Span X Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +52.1 psf/-135.3psf Other: +52.1 psf @ 5'-0" o.c. -46.9 psf @ 5'-0" -135.3 psf @ 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17700_R4_II_26 Ga. Super Span X Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_26 Ga. Super Span X Roof Panel.pdf Created by Independent Third Party: Yes |
|
|
| 17700.6 |
Super Span X Steel Roof Panel System |
Super Span X Steel Roof Panel System Over Open Framing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-60 psf Other: |
Installation Instructions FL17700_R4_II_Super Span X Roof Panel HVHZ Installation Details.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_24 Ga. Super Span X Roof Panel HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 17700.7 |
Weather Lok 16" Steel Roof Panel |
Weather Lok 16" Steel Roof Panel Over Open Framing
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-42.8 ps Other: |
Installation Instructions FL17700_R4_II_Weather Lok 16 Steel Roof Panel HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_Weather Lok 16 Steel Roof Panel HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 17700.8 |
Weather Lok Roof Panel |
24 Ga. Weather Lok Roof Panel over open framning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-109.3psf Other: Triple Lock: -46.9 psf @ 5'-0" o.c. -96.3 psf @ 2'-0" o.c. Quad Lock: -57.3 psf @ 5'-0" o.c. -109.3 psf @ 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17700_R4_II_24 Ga. Weather Lok Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17700_R4_AE_24 Ga. Weather Lok Roof Panel.pdf Created by Independent Third Party: Yes |