Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL17704-R4
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Whirlwind Steel Buildings
Address/Phone/Email 8234 Hansen Road
Houston, TX 77075
(832) 553-4659
wwsb.technical.contacts@whirlwindsteel.com
 
Authorized Signature Ronald Mays
wwsb.technical.contacts@whirlwindsteel.com
 
Technical Representative Jeremy Mathews
Address/Phone/Email 8234 Hansen Road
Houston, TX 77075
(832) 553-4811
wwsb.technical.contacts@whirlwindsteel.com
 
Quality Assurance Representative Ronald H Mays
Address/Phone/Email 8234 Hansen Road
Houston, TX 77075
(832) 553-4659
wwsb.technical.contacts@whirlwindsteel.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Lenard Gabert & Associates
Quality Assurance Contract Expiration Date 05/03/2025
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL17704_R4_COI_Letter of Certification.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/21/2023
Date Validated 09/24/2023
Date Pending FBC Approval 09/25/2023
Date Approved 12/12/2023
 
Summary of Products
FL # Model, Number or Name Description
17704.1 Sturdi-Rib X Roof Panel 29 Ga. Sturdi-Rib X Roof Panel over 7/16" OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5psf
 Other: -20.8 psf @ 24" o.c. -108.5 psf @ 6" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17704_R4_II_29 Ga. Sturdi-Rib X Roof Panel over OSB.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17704_R4_AE_29 Ga. Sturdi-Rib X Roof Panel over OSB.pdf
 Created by Independent Third Party: Yes
17704.2 Sturdi-Rib X Roof Panel 29 Ga. Sturdi-Rib X Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-138.5psf
 Other: -52.5 psf @ 30" o.c. -138.5 psf @ 18" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17704_R4_II_29 Ga. Sturdi-Rib X Roof Panel over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17704_R4_AE_29 Ga. Sturdi-Rib X Roof Panel over Plywood.pdf
 Created by Independent Third Party: Yes
17704.3 Weather Lok Roof Panel 24 Ga. Weather Lok Roof Panel over Steel Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-161.0psf
 Other: -63.5 psf @ 48" o.c. -161.0 psf @ 12" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17704_R4_II_24 Ga. Weather Lok Roof Panel over Steel Deck.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17704_R4_AE_24 Ga. Weather Lok Roof Panel over Steel Deck.pdf
 Created by Independent Third Party: Yes
17704.4 Weather Lok Roof Panel 24 Ga. Weather Lock Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-138.5psf
 Other: -71.0 psf @ 36" o.c. -138.5 psf @ 6" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17704_R4_II_24 Ga. Weather Lok Roof Panel over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17704_R4_AE_24 Ga. Weather Lok Roof Panel over Plywood.pdf
 Created by Independent Third Party: Yes
17704.5 Weather Snap Roof Panel 24 Ga. Weather Snap Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5psf
 Other: -78.5 psf @ 24" o.c. -108.5 psf @ 6" o.c. Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL17704_R4_II_24 Ga. Weather Snap Roof Panel over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17704_R4_AE_24 Ga. Weather Snap Roof Panel over Plywood.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 