| 17704.1 |
Sturdi-Rib X Roof Panel |
29 Ga. Sturdi-Rib X Roof Panel over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -20.8 psf @ 24" o.c. -108.5 psf @ 6" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17704_R4_II_29 Ga. Sturdi-Rib X Roof Panel over OSB.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17704_R4_AE_29 Ga. Sturdi-Rib X Roof Panel over OSB.pdf Created by Independent Third Party: Yes |
|
|
| 17704.2 |
Sturdi-Rib X Roof Panel |
29 Ga. Sturdi-Rib X Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5psf Other: -52.5 psf @ 30" o.c. -138.5 psf @ 18" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17704_R4_II_29 Ga. Sturdi-Rib X Roof Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17704_R4_AE_29 Ga. Sturdi-Rib X Roof Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 17704.3 |
Weather Lok Roof Panel |
24 Ga. Weather Lok Roof Panel over Steel Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.0psf Other: -63.5 psf @ 48" o.c. -161.0 psf @ 12" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17704_R4_II_24 Ga. Weather Lok Roof Panel over Steel Deck.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17704_R4_AE_24 Ga. Weather Lok Roof Panel over Steel Deck.pdf Created by Independent Third Party: Yes |
|
|
| 17704.4 |
Weather Lok Roof Panel |
24 Ga. Weather Lock Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5psf Other: -71.0 psf @ 36" o.c. -138.5 psf @ 6" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17704_R4_II_24 Ga. Weather Lok Roof Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17704_R4_AE_24 Ga. Weather Lok Roof Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 17704.5 |
Weather Snap Roof Panel |
24 Ga. Weather Snap Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -78.5 psf @ 24" o.c. -108.5 psf @ 6" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17704_R4_II_24 Ga. Weather Snap Roof Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17704_R4_AE_24 Ga. Weather Snap Roof Panel over Plywood.pdf Created by Independent Third Party: Yes |