| 31272.1 |
UWCA 3684 IZ3 |
Ultimate Wood Casement IZ3 407-H-1025 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 36" X 84-1/16" (914mm x 2111mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_CCL 1025.43.44.45.pdf Quality Assurance Contract Expiration Date 07/25/2032 Installation Instructions FL31272_R2_II_Install 1025.43.44.45.46.47.48 (00065800).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.2 |
UWCA 3697 IZ3 |
Ultimate Wood Casement IZ3 407-H-1025 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 36" X 96-1/16" (914mm x 2442mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_CCL 1025.46.47.48.pdf Quality Assurance Contract Expiration Date 07/26/2032 Installation Instructions FL31272_R2_II_Install 1025.43.44.45.46.47.48 (00065800).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.3 |
UWCA RT 3684 IZ3 |
Ultimate Wood Casement Round Top IZ3 407-H-1075 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 36" X 83-1/8" (914mm x 2111mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_1075.11.12.13.14.pdf Quality Assurance Contract Expiration Date 12/08/2027 Installation Instructions FL31272_R2_II_113992.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.4 |
UWCA RT P 3684 IZ3 |
Ultimate Wood Casement Round Top Picture IZ3 407-H-1051 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 36" X 83-1/8" (914mm x 2111mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_1051.14.15.16.17.pdf Quality Assurance Contract Expiration Date 09/11/2027 Installation Instructions FL31272_R2_II_70225.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.5 |
UWCA RT P 7278 IZ3 |
Ultimate Wood Casement Round Top Picture IZ3 407-H-1051 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 72-5/8" X 77-1/8" (1845mm x 1959mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_1051.10.11.12.13.pdf Quality Assurance Contract Expiration Date 09/11/2027 Installation Instructions FL31272_R2_II_70225.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.6 |
UWCA ST 3684 IZ3 |
Ultimate Wood Casement Stationary IZ3 407-H-1024 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 36" X 84-1/16" (914mm x 2135mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_CCL 1024.64.65.66.pdf Quality Assurance Contract Expiration Date 07/25/2032 Installation Instructions FL31272_R2_II_Install 1024.64.65.66 (00065800).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.7 |
UWCAP 4854 IZ3 |
Ultimate Wood Casement Picture IZ3 407-H-1024 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 48" X 54-1/16" (1219mm x 1373mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_CCL 1024.82.83.84.pdf Quality Assurance Contract Expiration Date 07/26/2032 Installation Instructions FL31272_R2_II_Install 1024.82.83.84.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.8 |
UWCAP IZ3 and UWCAPOP IZ3 60x105-5/8 |
Ultimate Wood Casement Picture IZ3 and Ultimate Wood Casement Push Out Picture IZ3 407-H-1024 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Max frame size 60" X 105-5/8" (1524mm x 2683mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_CCL 1024.70.71.72.pdf Quality Assurance Contract Expiration Date 07/26/2032 Installation Instructions FL31272_R2_II_CCL 1024.70.71.72.67.68.69.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 31272.9 |
UWCAP IZ3 and UWCAPOP IZ3 72x77-7/16 |
Ultimate Wood Casement Picture IZ3 and Ultimate Wood Casement Push Out Picture IZ3 407-H-1024 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max frame size 72-5/8" X 77-7/16" (1845mm x 1967mm) Glass complies with ASTM E1300 |
Certification Agency Certificate FL31272_R2_C_CAC_CCL 1024.67.68.69.pdf Quality Assurance Contract Expiration Date 07/26/2032 Installation Instructions FL31272_R2_II_Install 1024.67.68.69.70.71.72 (00065814).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |