42103.1 |
Stile |
Min. 26 ga., 39.4" wide through fastened roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-102.7 Other: Uplift load of 85.8 psf at fastener spacing of 24" o.c. and 102.7 psf at fastener spacing of 12" o.c. |
Installation Instructions FL42103_R1_II_EvaluationReportC2716_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL42103_R1_AE_EvaluationReportC2716_1.pdf Created by Independent Third Party: Yes |
|
42103.2 |
Stile |
Min. 26 ga., 39.4" wide through fastened roof panel over min. 19/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-149.6 Other: Uplift load of 50.4 psf at fastener spacing of 36" o.c., 106.8 psf at fastener spacing of 24" o.c. and 149.6 psf at fastener spacing of 12" o.c. |
Installation Instructions FL42103_R1_II_EvaluationReportC2716_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL42103_R1_AE_EvaluationReportC2716_2.pdf Created by Independent Third Party: Yes |