18582.1 |
Flush Glazed Fiberglass Door |
6'-8" Inswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55.0/-60.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0182-15 for additional information. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.01-R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0182.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514008C.pdf FL18582_R6_AE_514012C.pdf Created by Independent Third Party: Yes |
|
18582.2 |
Flush Glazed Fiberglass Door |
6'-8" Outswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60.0/-55.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0182-15 for additional information. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.01-R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0182.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514008C.pdf FL18582_R6_AE_514012C.pdf Created by Independent Third Party: Yes |
|
18582.3 |
Flush Glazed Fiberglass Door |
8'-0" Inswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45.0/-47.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0183-15 for additional information. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.02R3.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0183.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514007C.pdf FL18582_R6_AE_514011C.pdf Created by Independent Third Party: Yes |
|
18582.4 |
Flush Glazed Fiberglass Door |
8'-0" Outswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +47.0/-47.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0183-15 for additional information. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.02R3.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0183.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514007C.pdf FL18582_R6_AE_514011C.pdf Created by Independent Third Party: Yes |
|
18582.5 |
Flush Impact Glazed Fiberglass Door |
6'-8" Inswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-60 Other: Evaluated for use in locations adhering to the Florida Building Code excluding the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7 do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is not required. See DWG-MA-FL0260-22 for details. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.03R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0260.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514008C.pdf FL18582_R6_AE_514012C.pdf Created by Independent Third Party: Yes |
|
18582.6 |
Flush Impact Glazed Fiberglass Door |
6'-8" Outswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-55 Other: Evaluated for use in locations adhering to the Florida Building Code excluding the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7 do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is not required. See DWG-MA-FL0260-22 for details. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.03R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0260.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514008C.pdf FL18582_R6_AE_514012C.pdf Created by Independent Third Party: Yes |
|
18582.7 |
Flush Impact Glazed Fiberglass Door |
8'-0" Inswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-47 Other: Evaluated for use in locations adhering to the Florida Building Code excluding the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7 do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is not required. See DWG-MA-FL0261-22 for details. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.04-R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0261.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514007C.pdf FL18582_R6_AE_514011C.pdf Created by Independent Third Party: Yes |
|
18582.8 |
Flush Impact Glazed Fiberglass Door |
8'-0" Outswing Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +47/-47 Other: Evaluated for use in locations adhering to the Florida Building Code excluding the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7 do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is not required. See DWG-MA-FL0261-22 for details. |
Certification Agency Certificate FL18582_R6_C_CAC_NI012729.04-R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL18582_R6_II_DWG-MA-FL0261.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL18582_R6_AE_514007C.pdf FL18582_R6_AE_514011C.pdf Created by Independent Third Party: Yes |