| 16653.1 |
Heritage Series Inswing Entrance Door Sidelite |
50.13" x 98.72", Narrow Stiles, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-80 Other: Glass complies with the current ASTM E1300 standard; Positive design pressure +75 psf; Wood frame |
Certification Agency Certificate FL16653_R6_C_CAC_CCL 13023.pdf Quality Assurance Contract Expiration Date 10/02/2024 Installation Instructions FL16653_R6_II_13023_A Model (1).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16653.2 |
Heritage Series Inswing French Entrance Door |
74.19" x 98.72", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-45 Other: Glass complies with the current ASTM E1300 standard; 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel; Positive design pressure +35 psf; Wood frame |
Certification Agency Certificate FL16653_R6_C_CAC_CCL Project 23008 Recert 12197.pdf Quality Assurance Contract Expiration Date 01/26/2034 Installation Instructions FL16653_R6_II_12197 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16653.3 |
Ultra Series Inswing Entrance Door |
37.63" x 98.72", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass complies with the current ASTM E1300 standard; 5-point lock; Alum clad frame |
Certification Agency Certificate FL16653_R6_C_CAC_CCL 13053.pdf Quality Assurance Contract Expiration Date 04/25/2026 Installation Instructions FL16653_R6_II_13053 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16653.4 |
Ultra Series Inswing Entrance Door Sidelite |
50.13" x 98.72", Narrow Stiles, Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-70 Other: Glass complies with the current ASTM E1300 standard (3.9mm Ann - .090" SGP 3.9mm Ann), Single Glazed, (3.9 mm T - 8.0 mm SS - 3.9 mm Ann .090” SGP 3.9 mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; Alum clad frame |
Certification Agency Certificate FL16653_R6_C_CAC_CCL 13030, 13029.pdf Quality Assurance Contract Expiration Date 05/03/2026 Installation Instructions FL16653_R6_II_13029-30_A Model (1).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16653.5 |
Ultra Series Inswing Entrance Door Sidelite |
50.13" x 98.72", Narrow Stiles, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-80 Other: Glass complies with the current ASTM E1300 standard; Positive design pressure +75 psf; Alum clad frame |
Certification Agency Certificate FL16653_R6_C_CAC_CCL 13028.pdf Quality Assurance Contract Expiration Date 05/24/2026 Installation Instructions FL16653_R6_II_13028_A Model (1).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16653.6 |
Ultra Series Inswing French Entrance Door |
74.19" x 98.72", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-45 Other: Glass complies with the current ASTM E1300 standard; 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel; Alum clad frame |
Certification Agency Certificate FL16653_R6_C_CAC_CCL 22064 recert 13052.pdf Quality Assurance Contract Expiration Date 06/13/2033 Installation Instructions FL16653_R6_II_13052 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |