7751.1 |
Cougar LP |
0.6" x 10-1/2" wide continuous, under-the-shingle vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Created by Independent Third Party: Yes |
|
7751.2 |
Rapid Ridge |
Rapid Ridge Nail-Gunable Ridge Vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-190 Other: Refer to applicable building code for required ventilation, Rapid Ridge shall not be installed in conjunction with Gable Vents, Rapid Ridge shall not be installed on hip roofs, Rapid Ridge shall not be connected at ridge intersection, nor within 12" of any side wall or roof protrusion with a ventilation slot clearance of 12" from such obstructions, Rapid Ridge shall not be installed on roof mean heights greater than 33ft. |
Installation Instructions FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Created by Independent Third Party: Yes |
|
7751.3 |
Roll Vent |
0.9" x 10.25" x20'; 0.9" x10.25" x 50' rolled ridge vent, plastic |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-160 Other: Refer to applicable building code for required ventilation, Roll Vent shall not be installed in conjunction with Gable Vents, Roll Vent shall not be installed on hip roofs, Roll Vent shall not be connected at ridge intersection, nor within 12" of any side wall or roof protrusion with a ventilation slot clearance of 12" from such obstructions, Roll Vent shall not be installed on roof mean heights greater than 33ft. |
Installation Instructions FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Created by Independent Third Party: Yes |
|
7751.4 |
SharkVent XLP |
5/8" x 14-11/16" wide continuous, under-the-shingle vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Created by Independent Third Party: Yes |
|
7751.5 |
Xtractor Vent X18 |
13/16" x 14 3/4" wide x 4' lg., exterior convoluted baffled over ridge vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-180 Other: Refer to applicable building codes for required ventilation, X18 roof ventilator shall be installed over composition shingle roofs only, X18 roof ventilaor shall not be installed on roof mean heights greater than 33ft. |
Installation Instructions FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Created by Independent Third Party: Yes |
|
7751.6 |
Xtractor Vent XLP |
5/8" x 14" wide x 4' long |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-180 Other: Refer to applicable building codes for required ventilation, XLP roof ventilator shall be installed over composition shingle roofs only, XLP roof ventilaor shall not be installed on roof mean heights greater than 33ft. |
Installation Instructions FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf Created by Independent Third Party: Yes |