FL # FL7751-R9
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Benjamin Obdyke Incorporated
Address/Phone/Email 400 Babylon Road
Suite A
Horsham, PA 19044
(215) 672-7200   Ext 240
gcaruso@benjaminobdyke.com
 
Authorized Signature Kaylen Handly
khandly@obdyke.com
 
Technical Representative Kerry McEntee
Address/Phone/Email 400 Babylon Road
Suite A
Horsham, PA 19044
(215) 672-7200   Ext 341
kmcentee@obdyke.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2027
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL7751_R9_COI_CoI_CREEK Technical Services_2023.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 3302014
TAS 100(A)2023
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/20/2023
Date Validated 09/20/2023
Date Pending FBC Approval 09/24/2023
Date Approved 12/12/2023
 
Summary of Products
FL # Model, Number or Name Description
7751.1 Cougar LP 0.6" x 10-1/2" wide continuous, under-the-shingle vent
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: See evaluation report for limits of use.
Installation Instructions
 FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Verified By: Zachary R. Priest PE-74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Created by Independent Third Party: Yes
7751.2 Rapid Ridge Rapid Ridge Nail-Gunable Ridge Vent
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-190
 Other: Refer to applicable building code for required ventilation, Rapid Ridge shall not be installed in conjunction with Gable Vents, Rapid Ridge shall not be installed on hip roofs, Rapid Ridge shall not be connected at ridge intersection, nor within 12" of any side wall or roof protrusion with a ventilation slot clearance of 12" from such obstructions, Rapid Ridge shall not be installed on roof mean heights greater than 33ft.
Installation Instructions
 FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Verified By: Zachary R. Priest 74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Created by Independent Third Party: Yes
7751.3 Roll Vent 0.9" x 10.25" x20'; 0.9" x10.25" x 50' rolled ridge vent, plastic
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-160
 Other: Refer to applicable building code for required ventilation, Roll Vent shall not be installed in conjunction with Gable Vents, Roll Vent shall not be installed on hip roofs, Roll Vent shall not be connected at ridge intersection, nor within 12" of any side wall or roof protrusion with a ventilation slot clearance of 12" from such obstructions, Roll Vent shall not be installed on roof mean heights greater than 33ft.
Installation Instructions
 FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Verified By: Zachary R. Priest 74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Created by Independent Third Party: Yes
7751.4 SharkVent XLP 5/8" x 14-11/16" wide continuous, under-the-shingle vent
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: See evaluation report for limits of use.
Installation Instructions
 FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Verified By: Zachary R. Priest PE-74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Created by Independent Third Party: Yes
7751.5 Xtractor Vent X18 13/16" x 14 3/4" wide x 4' lg., exterior convoluted baffled over ridge vent
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-180
 Other: Refer to applicable building codes for required ventilation, X18 roof ventilator shall be installed over composition shingle roofs only, X18 roof ventilaor shall not be installed on roof mean heights greater than 33ft.
Installation Instructions
 FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Verified By: Zachary R. Priest 74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Created by Independent Third Party: Yes
7751.6 Xtractor Vent XLP 5/8" x 14" wide x 4' long
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-180
 Other: Refer to applicable building codes for required ventilation, XLP roof ventilator shall be installed over composition shingle roofs only, XLP roof ventilaor shall not be installed on roof mean heights greater than 33ft.
Installation Instructions
 FL7751_R9_II_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Verified By: Zachary R. Priest 74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL7751_R9_AE_BOI12002.6 2023 FBC Eval Roof Vents final.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 