20114.1 |
Siteline Clad or W-5500 Clad |
Casement 36" x 72" IG (5/16" PVB Lam in - 5/32" Annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-65 Other: |
Certification Agency Certificate FL20114_R10_C_CAC_406-H-823.01.02.pdf Quality Assurance Contract Expiration Date 11/06/2025 Installation Instructions FL20114_R10_II_Siteline Clad Casement Impact Installs 36 x 72_3-21-16.pdf FL20114_R10_II_Siteline Clad CS Impact 36x72 SS 2016-06-16.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL20114_R10_AE_PER4192 SS 2020-08-25.pdf Created by Independent Third Party: Yes |
|
20114.2 |
Siteline Clad or W-5500 Clad |
Casement 28" x 84" IG (5/16" PVB Lam in - 5/32" Annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-65 Other: |
Certification Agency Certificate FL20114_R10_C_CAC_406-H-823.12.pdf FL20114_R10_C_CAC_406-H-823.13.pdf Quality Assurance Contract Expiration Date 03/13/2024 Installation Instructions FL20114_R10_II_Siteline Clad Casement Impact Installs 28 x 84_3-21-16.pdf FL20114_R10_II_Siteline Clad CS Impact 28x84 SS 2016-06-16.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL20114_R10_AE_PER7356 SS 2020-12-07.pdf Created by Independent Third Party: Yes |
|
20114.3 |
Siteline Clad or W-5500 Clad |
Radius Top Casement 28" x 84" IG (5/16" PVB Lam in - 5/32" Annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-65 Other: |
Certification Agency Certificate FL20114_R10_C_CAC_406-H-823.15.pdf FL20114_R10_C_CAC_406-H-823.16.pdf Quality Assurance Contract Expiration Date 03/13/2024 Installation Instructions FL20114_R10_II_Siteline Clad Casement Radius Impact Install 28 x 84_10-5-16.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
20114.4 |
Siteline Clad or W-5500 Clad |
Radius Top Casement 36" x 72" IG (5/16" PVB Lam in - 5/32" Annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL20114_R10_C_CAC_406-H-823.09.10.pdf Quality Assurance Contract Expiration Date 04/19/2027 Installation Instructions FL20114_R10_II_36x72 Clad Casement Radius Impact_Installs.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |