14341.1 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 1219x2438mm (48x96in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 55.25 x 96.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |
|
14341.2 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 1219x2134mm (48x84in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 48 x 84.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |
|
14341.3 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 1219x1956mm (48x77in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 48 x 77.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |
|
14341.4 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 1219x1499mm (48x59in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 48 x 59.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |
|
14341.5 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 1143x1651mm (45x65in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 45 x 65.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |
|
14341.6 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 1041x1803mm (41x71in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 41 x 71.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |
|
14341.7 |
Pella Architect Reserve Double Hung, Clad, Model 5 (non impact) |
Size: 940x1956mm (37x77in) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: All glass meets the requirements of the current ASTM E1300 standard. |
Certification Agency Certificate FL14341_R7_C_CAC_CCL-ASCDH M5 37 x 77.pdf Quality Assurance Contract Expiration Date 10/11/2032 Installation Instructions FL14341_R7_II_Drawing 1734 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL14341_R7_AE_Drawing 1734 digitally sealed.pdf Created by Independent Third Party: Yes |