FL # FL14311-R6
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Corrim Company
Address/Phone/Email 1870 Stillman Drive
Oshkosh, WI 54901
(920) 231-2000
mmiller@corrim.com
 
Authorized Signature Frank Bennardo P.E.
frank@engineeringexpress.com
 
Technical Representative Mark Miller
Address/Phone/Email 3331 County Road A
Oshkosh, WI 54901
(920) 231-2000
mmiller@corrim.com
 
Quality Assurance Representative Mark Miller
Address/Phone/Email 3331 County Road A
Oshkosh, WI 54901
(920) 231-2000
mmiller@corrim.com
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Frank L. Bennardo, PE
Florida License PE-0046549
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2026
Validated By John Henry Kampmann Jr.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL14311_R6_COI_23-62474a - FL14311 - INDEP.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D19291996
ASTM D28431999
ASTM D6352003
ASTM D6382003
ASTM E18862002
ASTM E19962002
ASTM E3302002
ASTM G261996
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL14311_R6_Equiv_23-62474a - FL14311.1 - EQUIV.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/18/2024
Date Validated 01/06/2025
Date Pending FBC Approval 01/07/2025
Date Approved 02/11/2025
 
Summary of Products
FL # Model, Number or Name Description
14311.1 Fiberglass Outswing FRP Door Outswing Fiberglass Doors and Frames
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See installation instructions for limitations of use
Installation Instructions
 FL14311_R6_II_DS-23-62474b - FL14311.1 - DWG 1 1.pdf
 Verified By: Frank L. Bennardo, PE PE0046549
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14311_R6_AE_23-62474a - FL14311.1 - EVAL.pdf
 Created by Independent Third Party: Yes
 