47101.1 |
1 - TGM and Classic Inverter Mini-Split System |
See the "Installation Instructions" PDF for more information. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +140/-140 Other: Maximum-Rated ASD Wind Pressures: ± 140 psf Lateral, 111 psf Uplift. See the "Installation Instructions" PDF for limitations, conditions, and more information. |
Installation Instructions FL47101_R0_II__DWG1.pdf Verified By: Richard Neet, P.E. 86488 Created by Independent Third Party: Yes Evaluation Reports FL47101_R0_AE__EVAL1.pdf Created by Independent Third Party: Yes |
|
47101.2 |
2 - TGM 18 SEER Dual Capacity Series Condensing Units |
See the "Installation Instructions" PDF for more information. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +140/-140 Other: Maximum-Rated ASD Wind Pressures: ± 140 psf Lateral, 111 psf Uplift. See the "Installation Instructions" PDF for limitations, conditions, and more information. |
Installation Instructions FL47101_R0_II__DWG2.pdf Verified By: Richard Neet, P.E. 86488 Created by Independent Third Party: Yes Evaluation Reports FL47101_R0_AE__EVAL2.pdf Created by Independent Third Party: Yes |
|
47101.3 |
3 - TGM Condensing Units |
See the "Installation Instructions" PDF for more information. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +140/-140 Other: Maximum-Rated ASD Wind Pressures: ± 140 psf Lateral, 111 psf Uplift. See the "Installation Instructions" PDF for limitations, conditions, and more information. |
Installation Instructions FL47101_R0_II__DWG3.pdf Verified By: Richard Neet, P.E. 86488 Created by Independent Third Party: Yes Evaluation Reports FL47101_R0_AE__EVAL3.pdf Created by Independent Third Party: Yes |
|
47101.4 |
4 - TGM/Classic/Midea Light Commercial Units |
See the "Installation Instructions" PDF for more information. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +140/-140 Other: Maximum-Rated ASD Wind Pressures: ± 140 psf Lateral, 111 psf Uplift. See the "Installation Instructions" PDF for limitations, conditions, and more information. |
Installation Instructions FL47101_R0_II__DWG4.pdf Verified By: Richard Neet, P.E. 86488 Created by Independent Third Party: Yes Evaluation Reports FL47101_R0_AE__EVAL4.pdf Created by Independent Third Party: Yes |