11964.1 |
0.050" Bertha Aluminum Storm Panel (2 inch)- Drawing number 17-097 |
Corrugated aluminum Storm Panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile. Max. span is 13'-0" for +30, -30 p.s.f. ASD and 4'-0" for +90, -130 p.s.f. ASD for retained panels. See sheet 2 of installation drawing for other spans and pressures. |
Installation Instructions FL11964_R4_II_EASTERN METAL SUPPLY, INC._ DRAWING 17-097_ 0.050 BERTHA ALUMINUM STORM PANEL.PDF Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11964_R4_AE_EASTERN METAL SUPPLY, INC._ DRAWING 17-097_ PRODUCT EVALUATION REPORT.PDF Created by Independent Third Party: Yes |
|
11964.2 |
24 Gage Bertha Galvanized Steel Panel (2 inch) - Drawing number 17-089 |
Corrugated steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-10" for +32.6, -32.6 p.s.f. ASD and 2'-8" for +58.0, -58.0 p.s.f. ASD See sheet 2 of installation drawings for other spans and pressures. |
Installation Instructions FL11964_R4_II_EASTERN METAL SUPPLY, INC_DRAWING 17-089_24 GAGE GALVANIZED BERTHA STEEL STORM PANEL.PDF Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11964_R4_AE_EASTERN METAL SUPPLY, INC_DRAWING 17-089_ PRODUCT OF EVALUATION REPORT.PDF Created by Independent Third Party: Yes |